IBS ST 24 BK-T
INTERBUS-S
Data Sheet
Bus Terminal Module
08/1994
m
Data Sheet Revision A
co
Product Description
ne
nt
s.
The IBS ST 24 BK-T bus
terminal module is the head
station for an INTERBUS ST
compact
station
in
an
INTERBUS-S network.
on
l
in
ec
om
- INTERBUS-S protocol
- D-SUB 9 remote bus
connectors
- Electrical isolation of the
remote bus segments
- Electrical isolation of the logic
and I/O voltage
- Diagnostic LEDs
- Alarm output
- Reconfiguration input
- Replaceable electronics
- Rail mountable
(EN 50022)
po
Features
Applications
Connection of an INTERBUS ST
compact
station
to
the
INTERBUS-S remote bus.
50152001
Fig. 1: IBS ST 24 BK-T
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
1
Example of an Electrical Installation
Incoming remote bus
Outgoing remote bus
PE
50152004
co
m
ST cable
ne
nt
s.
Fig. 2: Exemplary connection of an IB ST compact station through the IBS ST 24 BK-T bus
terminal module to the INTERBUS-S remote bus. An IB ST compact station may consist
of up to 8 I/O modules.
om
po
Connect the mounting rail via ground terminals with protective earth (PE), as the
modules are grounded when they are snapped onto the rail.
Table 1: Ordering data
Order No.
Bus terminal module
IBS ST 24 BK-T
27 54 34 1
Module electronics, separately
IBS STME 24 BK-T
27 54 36 7
Terminal block, separately
IBS STTB 24 BK-T
27 53 18 0
Fuse, 1 A, slow-blow
IBS TR5 1AT
28 06 60 0
Insertion bridge, 80-pos., divisible, IN = 26A,
insulated back (5 pieces)
EB 80-DIK BU (blue)
EB 80-DIK RD (red)
27 15 94 0
27 15 95 3
Zack (“quick“) strip for terminal labeling
ZB 6 ... see Phoenix Contact Catalog, Part 3
MARKING, MOUNTING, Page 18
Mounting rail EN 50022, 2 meters
NS 35/7,5 perforated
NS 35/7,5 unperforated
in
ec
Type
on
l
Description
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
2
08 01 68 1
08 01 73 3
Connection
UL
+
UA
UREC
+
+
To be wired
externally
Internally
connected
9
13
14
15
16
4
5
6
7
8
E
LD RD
po
ne
nt
s.
UL RC BA
co
m
1
12
om
50272002
in
ec
Fig. 3: Connection of the supply voltage
Supply voltage for the bus logic
UA:
Supply voltage for the alarm contact (optional)
on
l
UL:
Alarm set
14
15
Alarm not set and
INTERBUS-S is connected
14
15
6
6
50151006
Fig. 4: Method of functioning of the alarm contact
UREC: Supply voltage for the reconfiguration input (optional). This input can only be used in
connection with a group definition. The reconfiguration input has the same potential as
the supply voltage. That means that the terminals 9 and 16 have to be connected.
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
3
Connection
Pin Assignment of the Male and Female Remote Bus Connector
Outgoing remote bus
9-pos. D-SUB male connector
9
Solder
side
/DO
DO
/DI
DI
COM
6
1
9
5
Solder
side
m
5
6
1
7
2
3
green
yellow
pink
gray
brown
bridged
Notes on how to assemble the cable
8
ne
3
nt
20
co
6
6
1
7
DI
2
COM 3
5
9
s.
1
/DO
DO
/DI
Incoming remote bus
9-pos. D-SUB female connector
in
ec
om
po
Strip the cable sheath 20 mm and bare the core ends 3 mm.
Shorten the braided screen by 12 mm.
on
l
Place the braided screen evenly around the cable sheath
Male/Female
Solder side
Clamp the shield under the cable grip
(conductive connection with the housing).
5015A005
Fig. 5: Connector pin assignment for the incoming and outgoing remote bus with information
on how to assemble the cable.
In order to reduce the installation time of an INTERBUS-S systems as much as
possible, Phoenix Contact offers pre-assembled bus cable in different lengths (see
Phoenix Contact Catalog, Part 11: INTERBUS).
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
4
Programming Data
Table 2: The most important data for the programmer
8 (decimal)
8 (hexadecimal)
Length code
0 (hexadecimal)
Input address area
0 bytes
Output address area
0 bytes
PCP address area
0 bytes
Register length
0 bytes
co
Programmable functions
Yes
Reset of the IB ST compact station
Yes
nt
Yes
on
l
in
ec
om
po
Monitoring of the remote bus cable
Yes
Yes
ne
Reset of the outgoing remote bus
s.
Disconnection of the IB ST compact station
Disconnection of the outgoing remote bus
m
Identification code
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
5
Technical Data
General
Type
Identification code
IBS ST 24 BK-T
08 (hex)
8 (dec)
0
0
IP 20
VDE 0110 part1, 01/89
From 0 °C to 55 °C
From -20 °C to 70 °C
81 mm * 117 mm * 116 mm
Length code
Register length
Degree of protection
Air and creepage distances
Permissible operating temperature
Permissible storage temperature
Housing dimensions (w * d * h)
m
Interfaces
INTERBUS-S
- Incoming remote bus
- Outgoing remote bus
- IB ST interface
om
in
ec
Alarm contact
- Terminal points
- Maximum voltage UA
- Maximum current
on
l
Reconfiguration input
- Terminal points
- Nominal voltage UREC
- Permissible range
- Current consumption (set)
Supply
Terminal points
Nominal voltage US
Permissible ripple
Permissible voltage range
Current consumption, primary:
- without IB ST local bus modules
- maximum
Current output, secondary (ST cable):
- maximum
Internal fuse
5015A
co
s.
nt
ne
400 m
Test voltage 500 V AC (50 Hz)
Test voltage 500 V AC (50 Hz)
po
Number of the connectible ST modules
Maximum distance to the next remote bus
module
Electrical isolation between
- incoming and outgoing remote bus
- incoming remote bus and
IB ST interface
D-SUB male connector, 9-pos.
D-SUB female connector, 9-pos.
ST cable (is included in the scope of delivery
of the I/O modules)
8
6, 14, 15 (see Figure 3)
30 V AC/DC
0.5 A
8 (+), 18 (-) (see Figure 4)
24 V DC
-30 V to +30 V (DC)
set: 13 V to 30 V (DC)
not set: -30 V to +1 V
2 mA typical
1 (+), 9 (-) (see Figure 3)
24 V (DC)
3.3 Vpp within the permissible voltage range
20 V to 30 V (DC)
150 mA typical (at 24 V)
650 mA typical (at 24 V)
800 mA (9 V)
IBS TR 5 , 1 A (slow-blow),
Order No.: 28 06 60 0
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
6
Technical Data
Local Diagnostic Indicators
green LED
on:
off:
supply voltage for the module electronics
supply voltage available
- supply voltage UL not available
- fuse of the BK defective
- internal power supply unit of the BK defective
BA
green LED
on:
off:
remote bus active
data transmission on INTERBUS active
no data transmission
RC
green LED
on:
off:
remote bus cable check
incoming remote bus connection established
incoming remote bus connection interrupted
E
red LED
on:
error
controller board located an error in this
compact station
LD
red LED
on:
compact station disabled
I/O modules of this compact station disabled
RD
red LED
on:
ne
nt
s.
co
m
UL
on
l
in
ec
om
po
remote bus disabled
outgoing remote bus disabled
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
7
TNR 92 65 63 9
DNR 2514
on
l
in
ec
om
po
ne
nt
s.
co
m
Notes:
5015A
Phoenix Contact GmbH & Co. Postfach 1341 32819 Blomberg Germany
8
很抱歉,暂时无法提供与“2754341”相匹配的价格&库存,您可以联系我们找货
免费人工找货