PSM-LWL-HCSO-200/230
HCS Optical Fiber Cable
HCS Optical Fiber Cable
For Permanent Outdoor Installation
co
m
Order No. 27 99 44 5
s.
1. Technical Data
nt
Fiber
Type
Attenuation at 650 nm
ne
200/230 µm step index fiber
≤ 10.0 dB/km (0°C to +70°C [+32°F to +158°F])
≤ 15.0 dB/km (-20°C to 0°C [-4°F to +32°F])
≤ 8.0 dB/km (0°C to +70°C [+32°F to +158°F])
≤ 12 dB/km (-20°C to 0°C [-4°F to +32°F])
≥ 17 MHz/km at 650 nm
≥ 20 MHz/km at 850 nm
0.37
Attenuation at 850 nm
po
Bandwidth length production
om
Numerical aperture
Single Element
in
ec
Material
Color
Conductor diameter
Strain relief elements
Bending radius
on
l
Twisting
Short period
Permanent
Outer Cable Sheath
Material
Color
Diameter
Rodent protection
Longitudinal water tightness
Marking
2 full wires for direct connection
of fiber optic connectors
Copolymer (FRNC), flame-retardant, halogen-free
Red/green
2.9 mm ±0.1 mm (0.114 in. ±0.004 in.) (for 3 mm [0.118 in.] crimping)
Non-metal, aramide yarn
30 mm (1.181 in.), minimum
50 mm (1.969 in.), minimum
2 single elements and 2 dummy elements twisted around an FRP
core and wrapped with fleece
Tearing wire
Polyethylene (PE)
Black
11 mm (0.433 in.)
Glass-fibre yarn
By swelling material
PHOENIX CONTACT FOC L (Date MM/YY)
AT-VQH(B)2Y 2K200/230 10A17 + 8B20 LG
and ID length specification in m
2 tearing wires under the outer cable sheath
Weight
90 kg/km
Temperature Range
Installation
Operation
Storage
-5˚C ... +50˚C (+23˚F ... +122˚F)
-20˚C ... +70˚C (-4˚F ... +158˚F)
-25˚C ... +70˚C (-13˚F ... +158˚F)
Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany
Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • http://www.phoenixcontact.com
Local contact: www.phoenixcontact.com/salesnetwork
PSM-LWL-HCSO-200/230 HCS Optical Fiber Cable
2. Mechanical Cable Properties According to EN 187 000
Bending radius
Procedure 513, Test Type 1
Tensile strength
Procedure 501
Lateral pressure
Procedure 504
Impact strength
Procedure 505
Longitudinal water tightness
Procedure 605
Short period
Permanent
Short period
Permanent
Short period
Permanent
150 mm (5.906 in.)
200 mm (7.874 in.)
1500 N, minimum
500 N, minimum
500 N/cm, minimum
300 N/cm, minimum
1.5 Nm/3 impacts,
minimum
1 m (3.28 ft.) cable, 1 m (3.281 ft.) water
column, 24 hours
m
3. Material Properties
Resistance to oil, benzene, acid, and lyes
Free of substances, which would hinder coating with paint or varnish
according to central standard P-VW 3.10.7 57650 of VW, Audi, and
Seat
IEC 60 754-2 A1:1997
DIN 53 387, Procedure 1, Condition A
1.68 MJ/m (0.47 kWh/m)
No toxic or corrosive combustion gases
co
Resistance to oil
Chloroform test
nt
s.
Free of halogen
UV resistance
Fire load
Combustion gases
ne
4. Structure
po
Tearing wires
Blindelement PE
PE dummy element
Außenmantel PE
PE outer cable sheath
Zentrales Stützelement
om
Central support element
F-SMA - quick mounting connector for HCS fibers
Set consists of 4 connectors
PSM-SET-FSMA/4-HCS
Order No. 27 99 48 7
Connector mounting set
PSM-HCS-KONFTOOL
Order No. 27 99 52 6
PHOENIX CONTACT page 2 of 2
TNR: 5087921-01
5. Recommended Connectors
01.03.99
Quellflies
Swelling
fleece
∀ PHOENIX CONTACT
Glass-fibre
yarn
rodent protection
Glasgarne
alsforNagetierschutz
on
l
in
ec
Aramidgarn
als
Zugentlastung
Aramide
yarn for
strain
relief
http://www.phoenixcontact.com
Faser
Coating
Wire
withmit
coating
很抱歉,暂时无法提供与“2799445”相匹配的价格&库存,您可以联系我们找货
免费人工找货