0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2800122

2800122

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    Module,Terminal Block

  • 描述:

    FLT-PLUS CTRL-2.5/I

  • 数据手册
  • 价格&库存
2800122 数据手册
https://www.phoenixcontact.com/us/products/2800122 Lightning arrester type 1 - FLT-PLUS CTRL-2.5/I - 2800122 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Type 1 / Class I (lightning current arrester) with arc chopping spark gap and ignition electronics with control lamp, quenching plates for high mains follow-through current quenching capacity, 1-channel. Protection level: 2.5 kV. Housing width: 35 mm (2 Div.) The illustration shows version FLTPLUS CTRL-0,9 Product Features  Good follow current quenching capacity with higher rated voltage  High discharge capacity  Direct parallel connection with type 2 arresters supported  Single-channel  Triggered   Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 560.0 GRM Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 150 mm Width 35.5 mm Depth 80.5 mm Horizontal pitch 2 Div. Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 85 °C Permissible humidity (operation) ≤ 95 % 01/13/2015   Page 1 / 6 https://www.phoenixcontact.com/us/products/2800122 Lightning arrester type 1 - FLT-PLUS CTRL-2.5/I - 2800122 Technical data General IEC power supply system TT TN-C TN-S IT Housing material PA-GF Inflammability class according to UL 94 V0 Color black Standards for air and creepage distances EN 60664-1 EN61643-11 Mounting type DIN rail: 35 mm Type Rail-mountable module, one-piece Number of positions 1 Surge protection fault message Optical Direction of action 1L-N/PE Protective circuit IEC test classification I T1 EN type T1 Nominal voltage UN 230 V AC (400 V AC) Maximum continuous operating voltage UC 440 V AC Maximum continuous operating voltage UC (L-N) 440 V AC Maximum continuous operating voltage UC (L-PEN) 440 V AC UT (TOV-proof) 440 V AC (5 sec.) UT (TOV-safe) 1640 V AC (200 ms) Nominal frequency fN 50 Hz 60 Hz Residual current IPE ≤ 3 mA Standby power consumption PC ≤ 1.32 VA Max. discharge current Imax (8/20) µs 50 kA Nominal discharge current In (8/20) µs 50 kA Nominal discharge current In (8/20) µs (L-N) 50 kA Nominal discharge current In (8/20) µs (L-PEN) 50 kA Impulse discharge current (10/350) µs charge 25 As Impulse discharge current (10/350)˽µs, specific energy 625 kJ/Ω Impulse discharge current (10/350)˽µs, peak value limp 50 kA Front of wave sparkover voltage at 6 kV (1.2/50) µs ≤ 2.5 kV 01/13/2015   Page 2 / 6 https://www.phoenixcontact.com/us/products/2800122 Lightning arrester type 1 - FLT-PLUS CTRL-2.5/I - 2800122 Technical data Protective circuit Voltage protection level Up ≤ 2.5 kV Voltage protection level Up (L-N) ≤ 2.5 kV Voltage protection level Up (L-PEN) ≤ 2.5 kV Response time ≤ 100 ns Response time (L-N) ≤ 100 ns Response time (L-PEN) ≤ 100 ns Max. backup fuse with branch wiring 500 A (NH-gL) Short-circuit resistance IP with max. backup fuse (effective) 25 kA (440 V AC) 50 kA (350 V AC) Follow current quenching capacity If 25 kA (440 V AC) 50 kA (350 V AC) Connection, protective circuit Connection method Screw connection Connection type IN Biconnect screw terminal block Connection type OUT Biconnect screw terminal block Connection method Biconnect terminal block Screw thread M6 Tightening torque 8 Nm Stripping length 19 mm Conductor cross section stranded min. 16 mm² Conductor cross section stranded max. 35 mm² Conductor cross section solid min. 10 mm² Conductor cross section solid max. 50 mm² Conductor cross section AWG/kcmil min. 6 Conductor cross section AWG/kcmil max 1 Standards and Regulations Standards/regulations IEC 61643-1 2005 DIN EN 61643-11 2002 DIN EN 61643-11/A11 2007 Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27140201 eCl@ss 5.0 27140201 01/13/2015   Page 3 / 6 https://www.phoenixcontact.com/us/products/2800122 Lightning arrester type 1 - FLT-PLUS CTRL-2.5/I - 2800122 Classifications eCl@ss eCl@ss 5.1 27140201 eCl@ss 6.0 27140201 eCl@ss 7.0 27140201 ETIM ETIM 2.0 EC000381 ETIM 3.0 EC000381 ETIM 4.0 EC000381 ETIM 5.0 EC000381 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals UL Recognized / KEMA-KEUR / cUL Recognized / GOST / GL / CCA / IECEE CB Scheme / cULus Recognized Ex Approvals Approvals submitted Approval details UL Recognized  01/13/2015   Page 4 / 6 https://www.phoenixcontact.com/us/products/2800122 Lightning arrester type 1 - FLT-PLUS CTRL-2.5/I - 2800122 Approvals KEMA-KEUR  cUL Recognized  GOST  GL  CCA  IECEE CB Scheme  cULus Recognized  Drawings Dimensioned drawing Circuit diagram 150 L/N( ) L/N( ) 51,5 29 45 01/13/2015   Page 5 / 6 https://www.phoenixcontact.com/us/products/2800122 Phoenix Contact 2015 © - all rights reserved http://www.phoenixcontact.com 01/13/2015   Page 6 / 6
2800122 价格&库存

很抱歉,暂时无法提供与“2800122”相匹配的价格&库存,您可以联系我们找货

免费人工找货