2800624

2800624

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    VAL-MS1000DC-PV-ST

  • 数据手册
  • 价格&库存
2800624 数据手册
https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Replacement plug for PV arrester combinations from the VAL-MS 1000DC-PV-... product range Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356615099 Weight per Piece (excluding packing) 100.000 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 52.4 mm Width 17.5 mm Depth 55.3 mm Horizontal pitch 1 Div. Ambient conditions Degree of protection IP20 Ambient temperature (operation) -40 °C ... 80 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Altitude ≤ 2000 m (amsl (above mean sea level)) Permissible humidity (operation) 5 % ... 95 % Shock (operation) 60g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) 06/28/2020   Page 1 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Technical data Ambient conditions Vibration (operation) 7.5g (5-500 Hz/2.5 h/XYZ) General IEC test classification PV II PV T2 EN type T2 SPD failure behavior OCM (Open-circuit mode) Installation location Interior Accessibility Accessible Installation location of the disconnect device Internal Mounting type on base element Color jet black RAL 9005 Housing material PA 6.6-FR Degree of pollution 2 Flammability rating according to UL 94 V-0 Type Male Surge protection fault message optical Protective circuit DC voltage side (DC) Maximum continuous operating voltage UCPV 585 V DC Short-circuit current rating ISCPV 2000 A Continuous operating current ICPV < 20 µA Standby power consumption PC ≤ 25 mVA Nominal discharge current (8/20) µs 15 kA Maximum discharge current Imax (8/20) µs 40 kA Voltage protection level Up ≤ 1.9 kV Residual voltage Ures ≤ 1.9 kV (at In) ≤ 1.5 kV (at 5 kA) ≤ 1.7 kV (at 10 kA) ≤ 2 kV (at 20 kA) ≤ 2.3 kV (at 30 kA) ≤ 2.5 kV (at 40 kA) Response time tA ≤ 25 ns Insulation resistance Riso > 5 GΩ (at 500 V DC) Connection data Connection method pluggable UL specifications 06/28/2020   Page 2 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Technical data UL specifications SPD Type 1CA Maximum continuous operating voltage MCOV 1170 V DC Nominal voltage 1170 V DC Mode of protection (L+) - (L-) (L+) - G (L-) - G Power distribution system DC PV Voltage protection rating VPR 3 kV Nominal discharge current In 10 kA Short-circuit current rating (SCCR) 50 kA Standards and Regulations Standards/regulations EN 50539-11 2013 Environmental Product Compliance China RoHS Environmentally friendly use period: unlimited = EFUP-e No hazardous substances above threshold values Drawings 06/28/2020   Page 3 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Circuit diagram 06/28/2020   Page 4 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Dimensional drawing Classifications eCl@ss eCl@ss 10.0.1 27130890 eCl@ss 4.0 27130800 eCl@ss 4.1 27130800 eCl@ss 5.0 27130800 eCl@ss 5.1 27130800 eCl@ss 6.0 27130800 eCl@ss 7.0 27130805 eCl@ss 8.0 27130890 eCl@ss 9.0 27130890 ETIM ETIM 3.0 EC000941 ETIM 4.0 EC000941 ETIM 5.0 EC002496 ETIM 6.0 EC000941 ETIM 7.0 EC000941 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 06/28/2020   Page 5 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Classifications UNSPSC UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 UNSPSC 18.0 39121620 UNSPSC 19.0 39121620 UNSPSC 20.0 39121620 UNSPSC 21.0 39121620 Approvals Approvals Approvals UL Recognized / KEMA-KEUR / cUL Recognized / EAC / cULus Recognized Ex Approvals Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330181 KEMA-KEUR    http://www.dekra-certification.com  71-102960 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 330181 EAC      RU CDE.A*30.B01561 06/28/2020   Page 6 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Approvals cULus Recognized       Accessories Accessories Device marking Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5     Labeled device marker Marker for terminal blocks - ZBN 18,LGS:ERDE - 2749589 Marker for terminal blocks, Strip, white, labeled, horizontal: Grounding symbol, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5     Marker for terminal blocks - ZBN 18,LGS:L1-N,ERDE - 2749576 Marker for terminal blocks, Strip, white, labeled, horizontal: L1, L2, L3, N, GND, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5     Marker pen 06/28/2020   Page 7 / 8 https://www.phoenixcontact.com/us/products/2800624 Type 2 surge protection plug - VAL-MS 1000DC-PV-ST - 2800624 Accessories Marker pen - B-STIFT - 1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm     Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 06/28/2020   Page 8 / 8
2800624 价格&库存

很抱歉,暂时无法提供与“2800624”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2800624
  •  国内价格 香港价格
  • 1+1118.836081+140.30420

库存:0