https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Thermomagnetic device circuit breaker, 1-pos., tripping characteristic F1 (fast-blow), 1 PDT contact, plug for base
element.
Your advantages
Compact design with precise nominal current levels
Modular expansion possible thanks to the uniform, plug-in housing concept
Sophisticated remote signaling concept enables monitoring from any location
Supply/remote signaling can be bridged with CLIPLINE complete accessories
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356690287
Weight per Piece (excluding packing)
40.000 g
Custom tariff number
85362010
Country of origin
Indonesia
Technical data
Dimensions
Height
45 mm
Width
12.3 mm
Depth
52 mm
Complete module height
90 mm
Complete module width
12.3 mm
Complete module depth
77.3 mm
09/12/2019 Page 1 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Technical data
Ambient conditions
Ambient temperature (operation)
-30 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Humidity test
240 h, 95 % RH, 40 °C
Shock (operation)
15g (According to IEC 60068-2-27, Test Ea)
Vibration (operation)
5g (In accordance with IEC 60068-2-6, Test Fc)
Degree of protection
IP30 (Actuation area)
General
Installation instructions
When mounted in rows, the nominal device current can be limited to just
80% or must be overdimensioned accordingly.
Flammability rating according to UL 94
V-0
Mounting type
on base element
Color
gray
Number of positions
1
Insulating material group
II
Degree of pollution
2
Type
Male
Electrical data
Fuse type
fast blow
Rated surge voltage
2.5 kV (Increased insulation in actuation area)
Rated voltage
50 V DC (IEC 60934)
50 V DC (UL 1077)
50 V DC (UL 508 - with plug-in base)
Rated current IN
2 A (IEC 60934)
inductive load according to UL 1077
2 A DC (low-induction load according to UL 1077)
2 A DC (inductive load according to UL 508 - with plug-in base)
2 A DC (low-induction load according to UL 508 - with plug-in base)
Rated insulation voltage Ui
277 V AC (UL 1077)
250 V AC (IEC 60934)
Switch-on delay
typ. 2 ms
Power dissipation
1.2 W (in nominal operation per channel)
Device resistance
300 mΩ
Insulation resistance Riso
> 100 MΩ (500 V DC)
Type of actuation
S type
Tripping method
TM (thermomagnetic)
Tripping level
Trip-free mechanism (positive)
09/12/2019 Page 2 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Technical data
Electrical data
600 A (50 V DC)
Required backup fuse
15 A (I > Icn)
Short-circuit switching capacity Ik
1000 A AC (277 V AC)
1000 A DC (50 V DC)
Dielectric strength
3000 V AC (Actuation area)
1500 V AC (Main to auxiliary circuit)
1500 V AC (Open main circuit)
1000 V AC (Open auxiliary circuit)
Voltage drop
0.64 V (at 1 x In)
Switching cycles, max.
6000 Number (at 1 x In)
Auxiliary circuit
277 V AC / 0.5 A (Low-induction)
277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
50 V DC / 1 A (Low-induction)
Minimum auxiliary contact operating voltage
10 V
Maximum auxiliary contact operating voltage
240 V
240 V
Minimum auxiliary contact operating current
10 mA
Maximum auxiliary contact operating current
1A
Standards and Regulations
Standards/specifications
EN 60934
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
09/12/2019 Page 3 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Circuit diagram
09/12/2019 Page 4 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Application drawing
09/12/2019 Page 5 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Diagram
Trigger characteristic in the DC range
09/12/2019 Page 6 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Dimensional drawing
The figure shows the complete module consisting of a base element and connector
09/12/2019 Page 7 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Application drawing
Classifications
eCl@ss
eCl@ss 4.0
27141100
eCl@ss 4.1
27141100
eCl@ss 5.0
27141100
09/12/2019 Page 8 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Classifications
eCl@ss
eCl@ss 5.1
27141100
eCl@ss 6.0
27141100
eCl@ss 7.0
27141116
eCl@ss 8.0
27141116
eCl@ss 9.0
27141116
ETIM
ETIM 3.0
EC000899
ETIM 4.0
EC000899
ETIM 5.0
EC000899
ETIM 6.0
EC000899
ETIM 7.0
EC000899
UNSPSC
UNSPSC 6.01
30211812
UNSPSC 7.0901
39121411
UNSPSC 11
39121411
UNSPSC 12.01
39121411
UNSPSC 13.2
39121410
Approvals
Approvals
Approvals
CSA / UL Listed / UL Recognized / cUL Recognized / cUL Listed / VDE Zeichengenehmigung / EAC / EAC / KC / DNV GL / CCC / cULus Recognized /
cULus Listed
Ex Approvals
Approval details
CSA
http://www.csagroup.org/services-industries/product-listing/
2786957
09/12/2019 Page 9 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Approvals
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 172140
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140459
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140459
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 172140
VDE Zeichengenehmigung
http://www2.vde.com/de/Institut/Online-Service/
VDE-gepruefteProdukte/Seiten/Online-Suche.aspx
40034683
EAC
EAC-Zulassung
EAC
RU CDE.A*30.B01561
KC
http://eng.kcc.go.kr/user/ehpMain.do
SW05012-15003
DNV GL
https://approvalfinder.dnvgl.com/
TAE00003C7
09/12/2019 Page 10 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Approvals
CCC
2019010307158887
cULus Recognized
cULus Listed
Accessories
Accessories
Bridge
Jumper - CB PT BRIDGE - 2801014
Bridge plug for bridging contacts 1 to 2 for CB base elements
Jumper - CB RC BRIDGE - 2801616
Bridge plug for bridging contacts 11 to 14 for CB base elements
Cutting tools
Front cutter - CUTFOX-FBS - 1212124
Cutting tool, for separating individual jumper bars from FBS ... plug-in bridges and EB ... insertion bridges
09/12/2019 Page 11 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Accessories
Jumper
Plug-in bridge - FBS 2-6 - 3030336
Plug-in bridge, pitch: 6.2 mm, width: 10.7 mm, number of positions: 2, color: red
Plug-in bridge - FBS 3-6 - 3030242
Plug-in bridge, pitch: 6.2 mm, width: 16.9 mm, number of positions: 3, color: red
Plug-in bridge - FBS 4-6 - 3030255
Plug-in bridge, pitch: 6.2 mm, width: 23.1 mm, number of positions: 4, color: red
Plug-in bridge - FBS 5-6 - 3030349
Plug-in bridge, pitch: 6.2 mm, width: 29.3 mm, number of positions: 5, color: red
Plug-in bridge - FBS 10-6 - 3030271
Plug-in bridge, pitch: 6.2 mm, width: 60.3 mm, number of positions: 10, color: red
09/12/2019 Page 12 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Accessories
Plug-in bridge - FBS 20-6 - 3030365
Plug-in bridge, pitch: 6.2 mm, width: 122.3 mm, number of positions: 20, color: red
Plug-in bridge - FBS 50-6 - 3032224
Plug-in bridge, pitch: 6.2 mm, width: 308.3 mm, number of positions: 50, color: red
Labeled terminal marker
Zack Marker strip, flat - ZBF 12 CUS - 0825018
Zack Marker strip, flat, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap
into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm, Number of individual labels:
5
Terminal marking
Zack Marker strip, flat - ZBF 12:UNBEDRUCKT - 0809735
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:
snap into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm, Number of individual
labels: 5
Necessary add-on products
09/12/2019 Page 13 / 14
https://www.phoenixcontact.com/us/products/2800859
Thermomagnetic device circuit breaker - CB TM1 2A F1 P - 2800859
Accessories
Base element - CB 1/6-2/4 PT-BE - 2800929
Base element with push-in connection technology for CB ... device circuit breakers
Base element - CB 1/10-1/10 UT-BE - 2801305
Base element with screw connection technology for CB... device circuit breakers
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com
09/12/2019 Page 14 / 14