https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Thermomagnetic device circuit breaker, 2-pos., tripping characteristic F1 (fast-blow), 2 PDT contacts, plug for
base element.
Product Description
Thermomagnetic device circuit breaker
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4046356690515
Weight per Piece (excluding packing)
71.000 g
Custom tariff number
85362010
Country of origin
Germany
Technical data
Dimensions
Height
45 mm
Width
24.6 mm
Depth
52 mm
Ambient conditions
Ambient temperature (operation)
-30 °C ... 60 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Humidity test
240 h, 95% RH, 40°C
Shock (operation)
15g (IEC 60068-2-27, Test Ea)
Degree of protection
IP30 (Actuation area)
03/09/2018 Page 1 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Technical data
General
Installation instructions
When mounted in rows, the nominal device current can be limited to just
80% or must be overdimensioned accordingly.
Flammability rating according to UL 94
V0
Mounting type
on base element
Color
gray
Number of positions
2
Insulating material group
II
Degree of pollution
2
Electrical data
Fuse type
fast blow
Rated surge voltage
2.5 kV (Increased insulation in actuation area)
80 V DC (IEC 60934)
80 V DC (UL 1077)
80 V DC (UL 508 - with plug-in base)
Rated current IN
0.5 A (IEC 60934)
inductive load according to UL 1077
0.5 A DC (low-induction load according to UL 1077)
0.5 A DC (inductive load according to UL 508 - with plug-in base)
0.5 A DC (low-induction load according to UL 508 - with plug-in base)
Rated insulation voltage Ui
277 V AC (UL 1077)
250 V AC (IEC 60934)
Power dissipation
1.25 W (in nominal operation per channel)
Insulation resistance Riso
> 100 MΩ (500 V DC)
Type of actuation
S type
Tripping method
TM (thermomagnetic)
Tripping level
Trip-free mechanism (positive)
600 A (80 V DC)
Required backup fuse
≥ 15 A (I > Icn)
Short-circuit switching capacity Ik
1000 A AC (277 V AC)
1000 A DC (50 V DC)
Dielectric strength
3000 V AC (Actuation area)
1500 V AC (Main to auxiliary circuit)
1500 V AC (Open main circuit)
1000 V AC (Open auxiliary circuit)
1500 V AC (Position to position)
Voltage drop
2.5 V (at 1 x In)
Switching cycles, max.
6000 (240 V AC/1 x In)
03/09/2018 Page 2 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Technical data
Electrical data
3000 (80 V DC/1 x In)
Contact type
2 PDT
Auxiliary circuit
277 V AC / 0.5 A (Low-induction)
277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
50 V DC / 1 A (Low-induction)
Minimum auxiliary contact operating voltage
10 V
Maximum auxiliary contact operating voltage
240 V
240 V
Minimum auxiliary contact operating current
10 mA
Maximum auxiliary contact operating current
1A
Vibration resistance, frequency
57 Hz ... 500 Hz
Vibration resistance, amplitude
± 0.38 mm (10 ... 57 Hz)
Vibration resistance, acceleration
49 m/s²
Vibration resistance, test duration
120 min. (Frequency cycles/axis)
Standards and Regulations
Standards/specifications
EN 60934
UL 1077 UL/C-UL recognized
UL 508 UL/C - UL listed
CSA 22.2 No. 235-041
Drawings
Diagram
90
45
24,6
Switching time [s]
Dimensional drawing
10000
0,5...6 A
8...16 A
1000
100
10
40,7
77,3
1
0,1
0,01
0,001
The figure shows the complete module consisting of a base element and
connector
1 2 4 6 10 20 40 100
2 4 6 10 20 40 100
Multiples of IN
Trigger characteristic in the DC range
03/09/2018 Page 3 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Application drawing
230 V
+ + - - Output DC 24V 10A
UOut
Signal
29,5V
24V
13
14
Rem
SGnd
Out 1
Out 2
QUINT POWER
> 100% Boost
> 75%
> 50%
DC OK
NFC
F2
F3
F4
F5
F6
F5
F6
10A
F1
10A
Input AC 100-240 V
N/- L/+
F7
F8
The figure shows the single-position versions
Classifications
eCl@ss
eCl@ss 4.0
27141116
eCl@ss 4.1
27141116
eCl@ss 5.0
27141116
eCl@ss 5.1
27141116
eCl@ss 6.0
27141116
eCl@ss 7.0
27141116
eCl@ss 8.0
27141116
eCl@ss 9.0
27141116
ETIM
ETIM 3.0
EC000899
03/09/2018 Page 4 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Classifications
ETIM
ETIM 4.0
EC000899
ETIM 5.0
EC000899
ETIM 6.0
EC000899
UNSPSC
UNSPSC 6.01
30211812
UNSPSC 7.0901
39121411
UNSPSC 11
39121411
UNSPSC 12.01
39121411
UNSPSC 13.2
39121410
Approvals
Approvals
Approvals
VDE Zeichengenehmigung / UL Recognized / cUL Recognized / GL / EAC / CSA / KC / cULus Recognized
Ex Approvals
Approval details
http://www.vde.com/en/Institute/OnlineService/
VDE-approved-products/Pages/Online-Search.aspx
40034683
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140459
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 140459
GL
http://exchange.dnv.com/tari/
61419-13 HH
VDE Zeichengenehmigung
03/09/2018 Page 5 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Approvals
RU CDE.A*30.B01561
CSA
http://www.csagroup.org/services-industries/product-listing/
2786957
KC
http://eng.kcc.go.kr/user/ehpMain.do
SW05012-15006
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
EAC
Accessories
Accessories
Bridge
Jumper - CB PT BRIDGE - 2801014
Bridge plug for bridging contacts 1 to 2 for CB base elements
Jumper - CB RC BRIDGE - 2801616
Bridge plug for bridging contacts 11 to 14 for CB base elements
Cutting tools
03/09/2018 Page 6 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Accessories
Front cutter - CUTFOX-FBS - 1212124
Cutting tool, for separating individual jumper bars from FBS ... plug-in bridges and EB ... insertion bridges
Jumper
Plug-in bridge - FBS 2-6 - 3030336
Plug-in bridge, pitch: 6.2 mm, width: 10.7 mm, number of positions: 2, color: red
Plug-in bridge - FBS 3-6 - 3030242
Plug-in bridge, pitch: 6.2 mm, width: 16.9 mm, number of positions: 3, color: red
Plug-in bridge - FBS 4-6 - 3030255
Plug-in bridge, pitch: 6.2 mm, width: 23.1 mm, number of positions: 4, color: red
Plug-in bridge - FBS 5-6 - 3030349
Plug-in bridge, pitch: 6.2 mm, width: 29.3 mm, number of positions: 5, color: red
03/09/2018 Page 7 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Accessories
Plug-in bridge - FBS 10-6 - 3030271
Plug-in bridge, pitch: 6.2 mm, width: 60.3 mm, number of positions: 10, color: red
Plug-in bridge - FBS 20-6 - 3030365
Plug-in bridge, pitch: 6.2 mm, width: 122.3 mm, number of positions: 20, color: red
Plug-in bridge - FBS 50-6 - 3032224
Plug-in bridge, pitch: 6.2 mm, width: 308.3 mm, number of positions: 50, color: red
Labeled terminal marker
Zack Marker strip, flat - ZBF 12 CUS - 0825018
Zack Marker strip, flat, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap
into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm
Terminal marking
Zack Marker strip, flat - ZBF 12:UNBEDRUCKT - 0809735
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type:
snap into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm
03/09/2018 Page 8 / 9
https://www.phoenixcontact.com/us/products/2800890
Thermomagnetic device circuit breaker - CB TM2 0.5A F1 P - 2800890
Accessories
Necessary add-on products
Base element - CB 1/6-2/4 PT-BE - 2800929
Base element with push-in connection technology for CB ... device circuit breakers
Base element - CB 1/10-1/10 UT-BE - 2801305
Base element with screw connection technology for CB... device circuit breakers
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
03/09/2018 Page 9 / 9