0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2800896

2800896

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CIR BRKR THRMMAG 6A 277VAC 80VDC

  • 数据手册
  • 价格&库存
2800896 数据手册
https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Thermomagnetic device circuit breaker, 2-pos., tripping characteristic F1 (fast-blow), 2 PDT contacts, plug for base element. Product Description Thermomagnetic device circuit breaker Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356690577 Weight per Piece (excluding packing) 50.000 g Custom tariff number 85362010 Country of origin Germany Technical data Dimensions Height 45 mm Width 24.6 mm Depth 52 mm Ambient conditions Ambient temperature (operation) -30 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 80 °C Humidity test 240 h, 95 % RH, 40 °C Shock (operation) 15g (IEC 60068-2-27, Test Ea) Vibration (operation) 5g (IEC 60068-2-6, Test Fc) 08/29/2019   Page 1 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Technical data Ambient conditions Degree of protection IP30 (Actuation area) General Installation instructions When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly. Flammability rating according to UL 94 V-0 Mounting type on base element Color gray Number of positions 2 Insulating material group II Degree of pollution 2 Type Male Electrical data Fuse type fast blow Rated surge voltage 2.5 kV (Increased insulation in actuation area) Rated voltage 80 V DC (IEC 60934) 80 V DC (UL 1077) 80 V DC (UL 508 - with plug-in base) Rated current IN 6 A (IEC 60934) inductive load according to UL 1077 6 A DC (low-induction load according to UL 1077) 6 A DC (inductive load according to UL 508 - with plug-in base) 6 A DC (low-induction load according to UL 508 - with plug-in base) Rated insulation voltage Ui 277 V AC (UL 1077) 250 V AC (IEC 60934) Power dissipation 1.8 W (in nominal operation per channel) Device resistance 50 mΩ Insulation resistance Riso > 100 MΩ (500 V DC) Type of actuation S type Tripping method TM (thermomagnetic) Tripping level Trip-free mechanism (positive) 600 A (80 V DC) Required backup fuse ≥ 24 A (I > Icn) Short-circuit switching capacity Ik 1000 A AC (277 V AC) 1000 A DC (50 V DC) Dielectric strength 3000 V AC (Actuation area) 1500 V AC (Main to auxiliary circuit) 08/29/2019   Page 2 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Technical data Electrical data 1500 V AC (Open main circuit) 1000 V AC (Open auxiliary circuit) 1500 V AC (Position to position) Voltage drop 0.29 V (at 1 x In) Switching cycles, max. 6000 (240 V AC/1 x In) 3000 (80 V DC/1 x In) Minimum auxiliary contact operating voltage 10 V Maximum auxiliary contact operating voltage 240 V 240 V Minimum auxiliary contact operating current 10 mA Maximum auxiliary contact operating current 1A Standards and Regulations Standards/specifications EN 60934 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Classifications eCl@ss eCl@ss 4.1 27141100 eCl@ss 5.1 27141100 eCl@ss 6.0 27141100 eCl@ss 7.0 27141116 eCl@ss 8.0 27141116 eCl@ss 9.0 27141116 ETIM ETIM 3.0 EC000899 ETIM 4.0 EC000899 ETIM 5.0 EC000899 ETIM 6.0 EC000899 ETIM 7.0 EC000899 08/29/2019   Page 3 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Classifications UNSPSC UNSPSC 6.01 30211812 UNSPSC 7.0901 39121411 UNSPSC 11 39121411 UNSPSC 12.01 39121411 UNSPSC 13.2 39121410 Approvals Approvals Approvals CSA / UL Recognized / cUL Recognized / VDE Zeichengenehmigung / EAC / KC / DNV GL / CCC / cULus Recognized Ex Approvals Approval details CSA    http://www.csagroup.org/services-industries/product-listing/  2786957 UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 140459 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 140459 VDE Zeichengenehmigung    http://www2.vde.com/de/Institut/Online-Service/ VDE-gepruefteProdukte/Seiten/Online-Suche.aspx  40034683 EAC      RU CDE.A*30.B01561 08/29/2019   Page 4 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Approvals KC    http://eng.kcc.go.kr/user/ehpMain.do  SW05012-15006 DNV GL    https://approvalfinder.dnvgl.com/  TAE00003C7 CCC      2019010307158887 cULus Recognized       Accessories Accessories Bridge Jumper - CB PT BRIDGE - 2801014 Bridge plug for bridging contacts 1 to 2 for CB base elements     Jumper - CB RC BRIDGE - 2801616 Bridge plug for bridging contacts 11 to 14 for CB base elements     Cutting tools 08/29/2019   Page 5 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Accessories Front cutter - CUTFOX-FBS - 1212124 Cutting tool, for separating individual jumper bars from FBS ... plug-in bridges and EB ... insertion bridges     Jumper Plug-in bridge - FBS 2-6 - 3030336 Plug-in bridge, pitch: 6.2 mm, width: 10.7 mm, number of positions: 2, color: red     Plug-in bridge - FBS 3-6 - 3030242 Plug-in bridge, pitch: 6.2 mm, width: 16.9 mm, number of positions: 3, color: red     Plug-in bridge - FBS 4-6 - 3030255 Plug-in bridge, pitch: 6.2 mm, width: 23.1 mm, number of positions: 4, color: red     Plug-in bridge - FBS 5-6 - 3030349 Plug-in bridge, pitch: 6.2 mm, width: 29.3 mm, number of positions: 5, color: red     08/29/2019   Page 6 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Accessories Plug-in bridge - FBS 10-6 - 3030271 Plug-in bridge, pitch: 6.2 mm, width: 60.3 mm, number of positions: 10, color: red     Plug-in bridge - FBS 20-6 - 3030365 Plug-in bridge, pitch: 6.2 mm, width: 122.3 mm, number of positions: 20, color: red     Plug-in bridge - FBS 50-6 - 3032224 Plug-in bridge, pitch: 6.2 mm, width: 308.3 mm, number of positions: 50, color: red     Labeled terminal marker Zack Marker strip, flat - ZBF 12 CUS - 0825018 Zack Marker strip, flat, can be ordered: Strip, white, labeled according to customer specifications, mounting type: snap into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm     Terminal marking Zack Marker strip, flat - ZBF 12:UNBEDRUCKT - 0809735 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 12 mm, lettering field size: 5.15 x 12.15 mm     08/29/2019   Page 7 / 8 https://www.phoenixcontact.com/us/products/2800896 Thermomagnetic device circuit breaker - CB TM2 6A F1 P - 2800896 Accessories Necessary add-on products Base element - CB 1/6-2/4 PT-BE - 2800929 Base element with push-in connection technology for CB ... device circuit breakers     Base element - CB 1/10-1/10 UT-BE - 2801305 Base element with screw connection technology for CB... device circuit breakers     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 08/29/2019   Page 8 / 8
2800896 价格&库存

很抱歉,暂时无法提供与“2800896”相匹配的价格&库存,您可以联系我们找货

免费人工找货