https://www.phoenixcontact.com/us/products/2801149
Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 75/12.5/1+1VFM - 2801149
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Universal varistor-based plug-in lightning/surge arrester for 48 V DC applications with grounded return conductor
(positive pole), without risk assessment for Lightning Protection Levels III and IV, with remote indication contact.
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
333.8 g
Custom tariff number
85363030
Country of origin
Germany
Technical data
Dimensions
Height
99 mm
Width
35.6 mm
Depth
77.5 mm
Horizontal pitch
2 Div.
Ambient conditions
Degree of protection
IP20 (only when all terminal points are used)
Ambient temperature (operation)
-40 °C ... 80 °C
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Altitude
≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)
5 % ... 95 %
Shock (operation)
30g (half sinus / 11 ms / 3x ±X, ±Y, ±Z)
Vibration (operation)
7.5g (10 ... 500 Hz / 2.5 h / X, Y, Z)
General
Standards/specifications
IEC 61643-11 2011
03/08/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/2801149
Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 75/12.5/1+1VFM - 2801149
Technical data
General
EN 61643-11 2012
IEC test classification
I / II
T1 / T2
T1
I
EN type
T1 / T2
T1
Number of ports
One
SPD design
Voltage-limiting type
Mode of protection
L-N
N-PE
(L+) - (L-)
(L+) - PE
Mounting type
DIN rail: 35 mm
Color
jet black RAL 9005
Housing material
PA 6.6
PBT
Degree of pollution
2
Flammability rating according to UL 94
V-0
Type
DIN rail module, two-section, divisible
Surge protection fault message
Optical, remote indicator contact
Protective circuit
Nominal voltage UN
60 V AC ±10 % (TN)
60 V DC ±10 %
Nominal frequency fN
50 Hz (60 Hz)
Maximum continuous voltage UC
75 V AC
Rated load current IL
80 A
Residual current IPE
≤ 0.6 mA
Standby power consumption PC
≤ 90 mVA
Nominal discharge current In (8/20) µs
12.5 kA
Maximum discharge current Imax (8/20) µs
50 kA
Impulse discharge current (10/350)˽µs, charge
6.25 As
Impulse discharge current (10/350)˽µs, specific energy
39 kJ/Ω
Impulse discharge current (10/350)˽µs, peak value limp
12.5 kA
Total discharge current ITotal (8/20) µs
50 kA
03/08/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/2801149
Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 75/12.5/1+1VFM - 2801149
Technical data
Protective circuit
Total discharge current ITotal (10/350) µs
12.5 kA
Short-circuit current rating ISCCR
0.5 kA
Voltage protection level Up
≤ 0.7 kV
Residual voltage Ures
≤ 0.7 kV (at In)
≤ 0.65 kV (at 10 kA)
≤ 0.6 kV (at 5 kV)
≤ 0.55 kV (at 4 kA)
≤ 0.55 kV (at 3 kA)
TOV behavior at UT
208 V AC (5 s / withstand mode)
100 V DC (5 s / withstand mode)
Response time tA
≤ 25 ns
Max. backup fuse with branch wiring
160 A (gG)
Max. backup fuse with V-type through wiring
80 A (gG - 16 mm²)
Indicator/remote signaling
Connection name
Remote fault indicator contact
Switching function
PDT contact
Operating voltage
5 V AC ... 250 V AC
125 V DC (200 mA DC)
Operating current
5 mA AC ... 1.5 A
1 A (30 V DC)
Connection method
Screw connection
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section flexible
0.14 mm² ... 1.5 mm²
Conductor cross section solid
0.14 mm² ... 1.5 mm²
Conductor cross section AWG
28 ... 16
Connection data
Connection method
Screw connection
Conductor cross section flexible
1.5 mm² ... 25 mm²
Conductor cross section solid
1.5 mm² ... 35 mm²
Conductor cross section AWG
15 ... 2
Screw thread
M5
Tightening torque
4.5 Nm
Stripping length
16 mm
03/08/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/2801149
Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 75/12.5/1+1VFM - 2801149
Technical data
UL specifications
SPD Type
4CA
Maximum continuous operating voltage MCOV (L-N)
75 V DC
Maximum continuous operating voltage MCOV (L-G)
75 V DC
Maximum continuous operating voltage MCOV (N-G)
75 V DC
Nominal voltage
60 V AC
Mode of protection
L-N
L-G
N-G
Power distribution system
1
Measured limiting voltage MLV (L-N)
2080 V
Measured limiting voltage MLV (L-G)
2080 V
Measured limiting voltage MLV (N-G)
3010 V
Nominal discharge current In (L-N)
20 kA
Nominal discharge current In (L-G)
20 kA
Nominal discharge current In (N-G)
20 kA
UL indicator/remote signaling
Operating voltage
125 V AC
Operating current
1A
Tightening torque
4 lbf-in.
Conductor cross section AWG
30 ... 14
UL connection data
Conductor cross section AWG
10 ... 2
Tightening torque
30 lbf-in.
Classifications
eCl@ss
eCl@ss 4.0
27140201
eCl@ss 4.1
27130801
eCl@ss 5.0
27130801
eCl@ss 5.1
27130801
eCl@ss 6.0
27130802
eCl@ss 7.0
27130802
eCl@ss 8.0
27130802
eCl@ss 9.0
27130802
03/08/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/2801149
Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 75/12.5/1+1VFM - 2801149
Classifications
ETIM
ETIM 3.0
EC000941
ETIM 4.0
EC000381
ETIM 5.0
EC000381
UNSPSC
UNSPSC 6.01
30212010
UNSPSC 7.0901
39121610
UNSPSC 11
39121610
UNSPSC 12.01
39121610
UNSPSC 13.2
39121620
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
UL Recognized
cUL Recognized
03/08/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/2801149
Lightning/surge arrester type 1/2 - VAL-MS-T1/T2 75/12.5/1+1VFM - 2801149
Approvals
cULus Recognized
Drawings
Dimensional drawing
Circuit diagram
99
22,5
70
77,5
45
N
51,5
L
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/08/2016 Page 6 / 6
很抱歉,暂时无法提供与“2801149”相匹配的价格&库存,您可以联系我们找货
免费人工找货