https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Surge protection, consisting of protective plug and base element, with integrated multi-stage status indicator
on the module, for two 2-wire floating signal circuits. Indirect grounding via gas-filled surge arrester, HARTcompatible.
Key Commercial Data
Packing unit
1 pc
GTIN
GTIN
4046356766470
Weight per Piece (excluding packing)
155.000 g
Custom tariff number
85363030
Country of origin
Germany
Technical data
Dimensions
Height
109.3 mm
Width
17.7 mm
Depth
77.5 mm (incl. DIN rail 7.5 mm)
Horizontal pitch
1 Div.
Ambient conditions
Ambient temperature (operation)
-40 °C ... 70 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Altitude
≤ 4000 m (amsl (above mean sea level))
Degree of protection
IP20
09/13/2019 Page 1 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Technical data
General
Housing material
PA 6.6
Flammability rating according to UL 94
V-0
Color
jet black RAL 9005
Mounting type
DIN rail: 35 mm
Type
DIN rail module, two-section, divisible
Direction of action
Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground
Additional descriptions
Note
Remote signaling as well as the power supply of the DIN rail connector are
established by snapping the module into place on the DIN rail connector.
Protective circuit
IEC test classification
C1
C2
C3
D1
Nominal voltage UN
24 V DC
Maximum continuous voltage UC
30 V DC
21 V AC
Rated current
700 mA (50 °C)
Operating effective current IC at UC
≤ 1 mA (in the signal circuit)
Residual current IPE
≤ 1 µA
Nominal discharge current In (8/20) µs (line-line)
10 kA
Nominal discharge current In (8/20) µs (line-earth)
10 kA
Nominal discharge current In (8/20) µs (line-signal ground)
10 kA
Pulse discharge current Iimp (10/350) µs (line-earth)
2.5 kA
Total discharge current Itotal (8/20) µs
20 kA
Voltage protection level Up (line-line)
≤ 80 V (C1 - 1 kV/500 A)
≤ 130 V (C2 - 10 kV / 5 kA)
≤ 55 V (C3 - 25 A)
≤ 60 V (C3 - 100 A)
Voltage protection level Up (line-earth)
≤ 900 V (C1 - 1 kV/500 A)
≤ 1300 V (C2 - 10 kV / 5 kA)
≤ 1000 V (C3 - 25 A)
≤ 1300 V (C3 - 100 A)
Voltage protection level Up (line-signalground)
≤ 600 V (C1 - 1 kV/500 A)
≤ 750 V (C2 - 10 kV / 5 kA)
09/13/2019 Page 2 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Technical data
Protective circuit
≤ 700 V (C3 - 25 A)
≤ 800 V (C3 - 100 A)
Voltage protection level Up static (line-line)
≤ 65 V (C1 - 1 kV/500 A)
Voltage protection level Up static (line-earth)
≤ 130 V (C2 - 10 kV / 5 kA)
Voltage protection level Up static (line-signalground)
≤ 60 V (C2 - 10 kV / 5 kA)
≤ 40 V (C3 - 25 A)
Response time tA (line-line)
≤ 1 ns
Response time tA (line-signalground)
≤ 100 ns
Response time tA (line-earth)
≤ 100 ns
Input attenuation aE, sym.
typ. 0.3 dB (≤ 270 kHz/150 Ω)
Cut-off frequency fg (3 dB), sym. in 150 Ohm system
typ. 1.1 MHz
Capacity (line-line)
typ. 2 nF
Resistance in series
1.2 Ω ±5 %
Surge protection fault message
Optical, multi-stage
Max. required back-up fuse
800 mA (FF)
Impulse durability (line-line)
C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
C2 - 10 kA
C3 - 100 A
Impulse durability (line-earth)
C1 - 1 kV / 500 A
C2 - 10 kV / 5 kA
C2 - 10 kA
C3 - 100 A
D1 - 2.5 kA
Impulse durability (line-signalground)
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C2 - 10 kA
C3 - 25 A
Pulse reset time (line-line)
≤ 4000 ms
Pulse reset time (line-earth)
≤ 30 ms
Pulse reset time (line-signalground)
≤ 2600 ms
Connection data
Connection method
Push-in connection
Stripping length
10 mm
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section solid
0.2 mm² ... 4 mm²
09/13/2019 Page 3 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Technical data
Connection data
Conductor cross section AWG
24 ... 12
Connection, equipotential bonding
Connection method
DIN rail NS35
Standards and Regulations
Standards/specifications
IEC 61643-21 2000 + A1:2008 + A2:2012
EN 61643-21 2001 + A1:2009 + A2:2013
EN 61000-6-3 2007 + A1:2011
EN 61000-6-2 2005
Environmental Product Compliance
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Diagram
09/13/2019 Page 4 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Dimensional drawing
Pictogram
09/13/2019 Page 5 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Circuit diagram
Classifications
eCl@ss
eCl@ss 4.0
27130800
eCl@ss 4.1
27130800
eCl@ss 5.0
27130800
eCl@ss 5.1
27130800
eCl@ss 6.0
27130800
eCl@ss 7.0
27130807
eCl@ss 8.0
27130807
eCl@ss 9.0
27130807
ETIM
ETIM 3.0
EC000943
ETIM 4.0
EC000943
ETIM 5.0
EC000943
ETIM 6.0
EC000943
ETIM 7.0
EC000943
UNSPSC
UNSPSC 6.01
30212010
UNSPSC 7.0901
39121610
UNSPSC 11
39121610
09/13/2019 Page 6 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Classifications
UNSPSC
UNSPSC 12.01
39121610
UNSPSC 13.2
39121620
Approvals
Approvals
Approvals
CSA / UL Listed / CSAus / EAC / cCSAus
Ex Approvals
Approval details
CSA
http://www.csagroup.org/services-industries/product-listing/
2761632
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 138168
CSAus
http://www.csagroup.org/services-industries/product-listing/
2761632
EAC
RU CDE.A*30.B01561
cCSAus
Accessories
Accessories
09/13/2019 Page 7 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Accessories
Device marking
Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128
Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap
into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm, Number of individual labels: 5
Labeled terminal marker
Zack Marker strip, flat - ZBF 5,LGS:FORTL.ZAHLEN - 0808671
Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ...
500, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm,
Number of individual labels: 10
Zack Marker strip, flat - ZBF 5,LGS:GERADE ZAHLEN - 0810821
Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 2 ... 20, 22 ... 40, etc. up to 82 ...
100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm,
Number of individual labels: 10
Zack Marker strip, flat - ZBF 5,LGS:UNGERADE ZAHLEN - 0810863
Zack Marker strip, flat, Strip, white, labeled, printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99,
mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number
of individual labels: 10
Zack Marker strip, flat - ZBF 5,QR:FORTL.ZAHLEN - 0808697
Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ...
100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm,
Number of individual labels: 10
09/13/2019 Page 8 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Accessories
Marker pen
Marker pen - X-PEN 0,35 - 0811228
Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm
Mounting material
End clamp - E/ME TBUS NS35 GY - 2713780
End clamp, stable construction for DIN rail bus connector
PCB plug
Printed-circuit board connector - FK-MC 0,5/ 5-ST-2,5 - 1881354
PCB connector, nominal current: 4 A, number of positions: 5, pitch: 2.5 mm, connection method: Push-in spring
connection, color: green, contact surface: Tin
Terminal marking
Zack Marker strip, flat - ZBF 5:UNBEDRUCKT - 0808642
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type:
snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.1 x 5.2 mm, Number of individual
labels: 10
09/13/2019 Page 9 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Accessories
Zack Marker strip, flat - ZBF 5/WH-100:UNBEDRUCKT - 0808668
Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type:
snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm, Number of individual
labels: 10
Necessary add-on products
Supply and remote module - PT-IQ-PTB-PT - 2801296
Module for power supply and multi-stage, floating remote signaling of connected surge protection modules.
Additional products
Shield connection - SSA 3-6 - 2839295
Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black
Shield connection - SSA 5-10 - 2839512
Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black
Spare parts
09/13/2019 Page 10 / 11
https://www.phoenixcontact.com/us/products/2801264
Surge protection device - PT-IQ-2X2+F-24DC-PT - 2801264
Accessories
Surge protection plug - PT-IQ-2X2-24DC-P - 2800804
Surge protection plug with integrated multi-stage status indicator on the module for two 2-wire floating signal circuits. 24
V DC nominal voltage.
DIN rail bus connectors - PT-IQ-17,5-TBUS-5-2.0 - 2906878
DIN rail connector for PT-IQ system for establishing remote signaling and the power supply when a surge protection
module is snapped on.
Phoenix Contact 2019 © - all rights reserved
http://www.phoenixcontact.com