2806090

2806090

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    CONN TERM BLOCK

  • 数据手册
  • 价格&库存
2806090 数据手册
https://www.phoenixcontact.com/us/products/2806090 Differential current monitoring - RCM-A-SCT-140 - 2806090 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Differential current converter for type A differential current monitor. Product Features  Residual current detection characteristics type A (50/60 Hz)  Detects pulsating DC and AC residual currents  Adjustable residual response current of 30 mA to 3 A  Adjustable pre-alarm threshold and delay time  Actual residual current can be read via LED display  Remote signaling for main and pre-alarm  Residual current monitoring devices act as a form of fire prevention Key commercial data Packing unit 1 pc Custom tariff number 85043180 Country of origin Germany Technical data Dimensions Height 220 mm Width 33 mm Depth 196 mm Diameter converter 140.00 mm Outside diameter of cables max. 93.00 mm Ambient conditions Degree of protection IP20 (terminal blocks) IP45 (housing) Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C 10/17/2014   Page 1 / 4 https://www.phoenixcontact.com/us/products/2806090 Differential current monitoring - RCM-A-SCT-140 - 2806090 Technical data General Housing material Polycarbonate Mounting type Screw mounting Common characteristics Rated current In 350 A Rated response differential current Idyn 3A Differential current acquisition characteristic Type A (50 / 60 Hz) Response differential current IΔn 0.03 A ... 3 A Thermal permanent differential current Icth 1.5 x In Thermal rated short-time differential current Ith 10 x In (for 1 s) Rated surge voltage resistance Uimp 8 kV Surge voltage category IV Rated voltage Un 690 V Pollution degree 2 Max. overcurrent as regards the non-resolution 6 x In Rated differential short-circuit current IΔc 10 kA Rated surge differential current Idyn 25 x In Connections Connection method Screw terminal blocks Number of connections 2 Stripping length 8 mm Conductor cross section stranded min. 0.2 mm² Conductor cross section stranded max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Cable/line name Converter supply line Maximum cable length 10 m Cross section 0.5 mm² Cable type LiY Standards and Regulations Standards/specifications DIN EN 62020 VDE 0663 DIN EN 60044-1 VDE 0414 10/17/2014   Page 2 / 4 https://www.phoenixcontact.com/us/products/2806090 Differential current monitoring - RCM-A-SCT-140 - 2806090 Classifications eCl@ss eCl@ss 4.0 27210902 eCl@ss 4.1 27210902 eCl@ss 5.0 27210902 eCl@ss 5.1 27210902 eCl@ss 6.0 27210902 eCl@ss 7.0 27210902 eCl@ss 8.0 27210902 ETIM ETIM 2.0 EC001505 ETIM 3.0 EC001505 ETIM 4.0 EC002048 ETIM 5.0 EC002048 UNSPSC UNSPSC 6.01 30211501 UNSPSC 7.0901 39121019 UNSPSC 11 39121006 UNSPSC 12.01 39121006 UNSPSC 13.2 39121006 Approvals Approvals Approvals VDE Zeichengenehmigung Ex Approvals Approvals submitted Approval details 10/17/2014   Page 3 / 4 https://www.phoenixcontact.com/us/products/2806090 Differential current monitoring - RCM-A-SCT-140 - 2806090 Approvals VDE Zeichengenehmigung  Phoenix Contact 2014 © - all rights reserved http://www.phoenixcontact.com 10/17/2014   Page 4 / 4
2806090 价格&库存

很抱歉,暂时无法提供与“2806090”相匹配的价格&库存,您可以联系我们找货

免费人工找货