2807955

2807955

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    LSA-PLUS PLUG W/SURGE VOLTAG

  • 详情介绍
  • 数据手册
  • 价格&库存
2807955 数据手册
Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. LSA-PLUS plug (COMTRAB CT 10) with coarse/fine surge protection, for 10 floating signal circuits. Nominal voltage: 24 V DC. Version: 10 double wires. Your advantages • Space-saving due to compact design • Flexible fields of application with modular protective plug • Can be used in LSA-PLUS disconnect and control strips or CT-TERMIBLOCK via adapted connection technology Commercial Data Item number 2807955 Packing unit 1 pc Minimum order quantity 1 pc Note Made to Order (non-returnable) Sales Key C08 Product Key CL3212 Catalog Page Page 106 (C-6-2013) GTIN 4017918104740 Weight per Piece (including packing) 125.3 g Weight per Piece (excluding packing) 125.15 g Customs tariff number 85363010 Country of origin DE Dec 2, 2022, 5:36 PM Page 1 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Technical Data Product properties IEC test classification C1 C2 C3 D1 Type LSA-PLUS module Product type Surge protection for MCR technology Surge protection fault message none Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Wire pairs per module 10 Insulation characteristics Overvoltage category II Connection data Connection method can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips Dimensions Dimensional drawing Width 111 mm Height 22 mm Depth 68.5 mm Material specifications Color black Flammability rating according to UL 94 V0 Housing material PBT Mechanical properties Mechanical data Open side panel No Protective circuit Direction of action Line-Line & Line-Earth Ground Maximum continuous voltage UC 40 V DC Dec 2, 2022, 5:36 PM Page 2 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 28 V AC Operating effective current IC at UC ≤ 5 µA (a-b) Residual current IPE ≤ 1 µA (per path) Nominal discharge current In (8/20) µs (line-line) 119 A (25 °C) Nominal discharge surge current In (8/20) µs (Core-Earth) 5 kA Total surge current (8/20) µs 10 kA Max. discharge current Imax (8/20) µs maximum (line-line) 119 A (25 °C) Max. discharge current Imax (8/20) µs maximum (line-earth) 5 kA Nominal pulse current Ian (10/1000) µs (line-line) 23 A (25 °C) Output voltage limitation at 1 kV/µs (line-line) spike ≤ 70 V Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 650 V Output voltage limitation at 1 kV/µs (line-line) static ≤ 60 V Output voltage limitation at 1 kV/µs (line-earth) static ≤ 650 V Residual voltage at In (conductor-conductor) ≤ 85 V Residual voltage with Ian (10/1000) µs (line-line) ≤ 65 V Response time tA (line-line) ≤ 1 ns Response time tA (line-earth) ≤ 100 ns Input attenuation aE, sym. 0.1 dB (Typ. up to 2 MHz / 50 Ω) 0.1 dB (Typ. up to 1 MHz / 150 Ω) 0.1 dB (Typ. up to 400 kHz / 600 Ω) Cut-off frequency fg (3 dB), sym. in 50 Ω system 10 MHz (typ.) Cut-off frequency fg (3 dB), sym. in 150 Ω system 4 MHz (typ.) Cut-off frequency fg (3 dB), sym. in 600 Ω system 1 MHz (typ.) Capacity (Core-Core) 1.1 nF (f=1 MHz / VR= 0 V) Capacity (Core-Earth) 1 pF Surge protection fault message none Impulse durability (line-earth) C1 - 1 kV / 500 A C2 - 10 kV / 5 kA C3 - 100 A D1 - 2.5 kA Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 75 °C Standards and regulations Air clearances and creepage distances Standards/regulations VDE 0110-1 / IEC 60664-1 Standards Information technology specification Standards/regulations IEC 61643-21 IEC 61643-21 Standards/specifications IEC 61643-21 Dec 2, 2022, 5:36 PM Page 3 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Mounting Mounting type On CT-TERMIBLOCK and LSA-PLUS disconnect strip Dec 2, 2022, 5:36 PM Page 4 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Drawings Circuit diagram 1.../19 1'.../19’ OUT IN 2.../20 2'.../20’ Dimensional drawing 22 68,5 111 Dec 2, 2022, 5:36 PM Page 5 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Approvals  EAC  EAC Approval ID: EAC-Zulassung Approval ID: RU C-DE.*09.B.00169 Dec 2, 2022, 5:36 PM Page 6 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Classifications ECLASS ECLASS-9.0 27130807 ECLASS-10.0.1 27130807 ECLASS-11.0 27130807 ETIM ETIM 8.0 EC000943 UNSPSC UNSPSC 21.0 39121600 Dec 2, 2022, 5:36 PM Page 7 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Dec 2, 2022, 5:36 PM Page 8 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Mandatory Accessories Disconnect strip Disconnect strip - CT 10-TL - 2765356 https://www.phoenixcontact.com/us/products/2765356 LSA-PLUS disconnect strip to hold the CTM and CT 10 protection modules. Version: 10 double conductors, dimension A: 124 mm. Accessories Screw termination block Screw termination block - CT-TERMIBLOCK 10 DA - 0441711 https://www.phoenixcontact.com/us/products/0441711 Screw termination block with disconnect contacts for accommodating protective plugs CT and CTM. Use in MCR and telecommunications systems. Design: 10 double wires Dec 2, 2022, 5:36 PM Page 9 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Mounting clip Mounting clip - CT 10-MB/ 3 - 2765372 https://www.phoenixcontact.com/us/products/2765372 Mounting clip, for holding 3 disconnect or ground wire strips. Version: 10 double conductors, dimensions: A 104.5 mm, B 65 mm. Shield connection Shield connection - SSA 3-6 - 2839295 https://www.phoenixcontact.com/us/products/2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm2, color: black Dec 2, 2022, 5:36 PM Page 10 (11) Surge protection plug - CT 10-2PE/FS-24 2807955 https://www.phoenixcontact.com/us/products/2807955 Shield connection Shield connection - SSA 5-10 - 2839512 https://www.phoenixcontact.com/us/products/2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm2, color: black Phoenix Contact 2022 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Dec 2, 2022, 5:36 PM Page 11 (11)
2807955
物料型号为 2807955,这是Phoenix Contact公司生产的LSA-PLUS 10路信号保护插头,用于10个浮动信号回路的粗/细浪涌保护,额定电压为24V DC。


器件简介:该产品具有紧凑设计,节省空间,使用模块化保护插头具有灵活的应用领域,可用于LSA-PLUS断开和控制带或通过适配的连接技术在CT-TERMIBLOCK上使用。


引脚分配:该模块每个模块有10对线对。


参数特性:该产品的技术数据包括IEC测试分类、类型、产品类型、浪涌保护故障信息、可使用软件版本测试浪涌保护器、每模块线对数、绝缘特性、过电压类别、连接数据、尺寸、材料规格、机械属性、保护电路、环境和实际条件、标准和法规、安装、图纸、认证、分类和环境产品合规性。


功能详解:该产品为MCR技术提供浪涌保护,具有无故障消息,可以与CHECKMASTER软件版本1.00及以上版本一起测试,具有线对数为10,绝缘特性满足要求,过电压类别为C1 C2 C3 D1。

其最大连续电压为40V DC,28V AC下的操作有效电流为5A。

浪涌保护故障信息为无,具有多种浪涌电流和脉冲电流规格,以及输出电压限制和残余电压要求。

响应时间为线对线1ns,线对地100ns。

输入衰减和截止频率也满足特定的要求。


应用信息:该产品可用于需要信号保护的应用,如MCR和电信系统。


封装信息:该产品的尺寸为宽111mm、高22mm、深68.5mm,材料为黑色PBT,符合UL 94 V0的可燃性等级。


此外,该产品还包含一些必要的附件,如断开条、螺丝端子块、安装夹和屏蔽连接。
2807955 价格&库存

很抱歉,暂时无法提供与“2807955”相匹配的价格&库存,您可以联系我们找货

免费人工找货