2807968

2807968

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    LSA-PLUS PLUG W/SURGE VOLTAGE

  • 详情介绍
  • 数据手册
  • 价格&库存
2807968 数据手册
Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. LSA-PLUS plug (COMTRAB CT 10) with coarse/fine surge protection and decoupling resistor for 10 floating signal circuits. Nominal voltage: 24 V DC. Version: 10 double wires. Your advantages • Space-saving due to compact design • Flexible fields of application with modular protective plug • Can be used in LSA-PLUS disconnect and control strips or CT-TERMIBLOCK via adapted connection technology Commercial Data Item number 2807968 Packing unit 1 pc Minimum order quantity 1 pc Note Made to Order (non-returnable) Sales Key C08 Product Key CL3212 Catalog Page Page 107 (C-6-2013) GTIN 4017918104757 Weight per Piece (including packing) 127 g Weight per Piece (excluding packing) 127 g Customs tariff number 85363010 Country of origin DE Dec 2, 2022, 5:38 PM Page 1 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Technical Data Product properties IEC test classification C1 C2 C3 D1 Type LSA-PLUS module Product type Surge protection for MCR technology Surge protection fault message none Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Wire pairs per module 10 Connection data Connection method can be plugged into COMTRAB-TERMIBLOCK and LSA-PLUS disconnect and switching strips Dimensions Dimensional drawing Width 111 mm Height 22 mm Depth 68.5 mm Material specifications Color black Flammability rating according to UL 94 V0 Housing material PBT Mechanical properties Mechanical data Open side panel No Protective circuit Direction of action Line-Line & Line-Earth Ground Maximum continuous voltage UC 40 V DC 28 V AC Rated current 200 mA (25 °C) Operating effective current IC at UC ≤ 5 µA (a-b) Residual current IPE ≤ 1 µA (per path) Dec 2, 2022, 5:38 PM Page 2 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Nominal discharge current In (8/20) µs (line-line) 5 kA Nominal discharge surge current In (8/20) µs (Core-Earth) 5 kA Total discharge current Itotal (8/20) µs 10 kA Max. discharge current Imax (8/20) µs maximum (line-line) 5 kA Max. discharge current Imax (8/20) µs maximum (line-earth) 5 kA Output voltage limitation at 1 kV/µs (line-line) spike ≤ 95 V Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 650 V Output voltage limitation at 1 kV/µs (line-line) static ≤ 60 V Output voltage limitation at 1 kV/µs (line-earth) static ≤ 650 V Residual voltage at In (conductor-conductor) ≤ 55 V Response time tA (line-line) ≤ 1 ns Response time tA (line-earth) ≤ 100 ns Input attenuation aE, sym. 1.5 dB (Typ. up to 2 MHz / 50 Ω) 0.6 dB (Typ. up to 1 MHz / 150 Ω) 0.2 dB (Typ. up to 100 kHz / 600 Ω) Cut-off frequency fg (3 dB), sym. in 50 Ω system 7 MHz (typ.) Cut-off frequency fg (3 dB), sym. in 150 Ω system 4 MHz (typ.) Cut-off frequency fg (3 dB), sym. in 600 Ω system 900 kHz (typ.) Capacity (Core-Core) 1.1 nF (f=1 MHz / VR= 0 V) Capacity (Core-Earth) 1 pF (typ.) Resistance per path 10 Ω ±10 % Surge protection fault message none Max. required back-up fuse 200 mA Impulse durability (line-line) C1 - 1 kV / 500 A C2 - 10 kV / 5 kA C3 - 100 A Impulse durability (line-earth) C1 - 1 kV / 500 A C2 - 10 kV / 5 kA C3 - 100 A D1 - 2.5 kA Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 75 °C Standards and regulations Air clearances and creepage distances Standards/regulations VDE 0110-1 / IEC 60664-1 Standards Information technology specification Standards/regulations IEC 61643-21 IEC 61643-21 Standards/specifications IEC 61643-21 Dec 2, 2022, 5:38 PM Page 3 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Mounting Mounting type On CT-TERMIBLOCK and LSA-PLUS disconnect strip Dec 2, 2022, 5:38 PM Page 4 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Drawings Circuit diagram 1.../19 1'.../19’ OUT IN 2.../20 2'.../20’ Dimensional drawing 22 68,5 111 Dec 2, 2022, 5:38 PM Page 5 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Approvals  EAC  EAC Approval ID: EAC-Zulassung Approval ID: RU C-DE.*09.B.00169 Dec 2, 2022, 5:38 PM Page 6 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Classifications ECLASS ECLASS-9.0 27130807 ECLASS-10.0.1 27130807 ECLASS-11.0 27130807 ETIM ETIM 8.0 EC000943 UNSPSC UNSPSC 21.0 39121600 Dec 2, 2022, 5:38 PM Page 7 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Dec 2, 2022, 5:38 PM Page 8 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Mandatory Accessories Disconnect strip Disconnect strip - CT 10-TL - 2765356 https://www.phoenixcontact.com/us/products/2765356 LSA-PLUS disconnect strip to hold the CTM and CT 10 protection modules. Version: 10 double conductors, dimension A: 124 mm. Accessories Screw termination block Screw termination block - CT-TERMIBLOCK 10 DA - 0441711 https://www.phoenixcontact.com/us/products/0441711 Screw termination block with disconnect contacts for accommodating protective plugs CT and CTM. Use in MCR and telecommunications systems. Design: 10 double wires Dec 2, 2022, 5:38 PM Page 9 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Mounting clip Mounting clip - CT 10-MB/ 3 - 2765372 https://www.phoenixcontact.com/us/products/2765372 Mounting clip, for holding 3 disconnect or ground wire strips. Version: 10 double conductors, dimensions: A 104.5 mm, B 65 mm. Shield connection Shield connection - SSA 3-6 - 2839295 https://www.phoenixcontact.com/us/products/2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm2, color: black Dec 2, 2022, 5:38 PM Page 10 (11) Surge protection plug - CT 10-2PE/FSR-24 2807968 https://www.phoenixcontact.com/us/products/2807968 Shield connection Shield connection - SSA 5-10 - 2839512 https://www.phoenixcontact.com/us/products/2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm2, color: black Phoenix Contact 2022 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Dec 2, 2022, 5:38 PM Page 11 (11)
2807968
物料型号:2807968

器件简介:PHOENIX CONTACT生产的LSA-PLUS插头,具有粗/细浪涌保护和解耦电阻,适用于10个浮动信号电路。额定电压为24V直流。

引脚分配:10对双线。

参数特性: - IEC测试分类:C1 C2 C3 D1 - 连接方式:可插入COMTRAB-TERMIBLOCK和LSA-PLUS断开和开关条 - 尺寸:宽111mm,高22mm,深68.5mm - 材料:黑色PBT,UL94阻燃等级V0 - 保护电路:动作方向为线对线和线对地,最大连续电压40VDC/28VAC,额定电流200mA(25°C),操作有效电流5A(a-b),残余电流每条路径1uA

功能详解: - 额定放电电流5kA(线对线和线对地) - 输出电压限制:线对线尖峰≤95V,线对地尖峰≤650V,线对线静态≤60V,线对地静态≤650V - 响应时间:线对线1ns,线对地100ns - 输入衰减:1.5dB(典型值,高达2MHz/50),0.6dB(典型值,高达1MHz/150),0.2dB(典型值,高达100kHz/600) - 截止频率:7MHz(典型值,50系统),4MHz(典型值,150系统),900kHz(典型值,600系统)

应用信息:可用于LSA-PLUS断开和控制条或通过适配连接技术在CT-TERMIBLOCK中使用。

封装信息:产品重量127g(含包装),海关关税编号85363010,原产国为德国。

环境和实际条件: - 保护等级:IP20 - 环境温度(运行):-25°C至75°C

标准和法规:符合IEC61643-21标准。

安装:可在CT-TERMIBLOCK和LSA-PLUS断开条上安装。

认证:EAC认证,ID为EAC-Zulassung,RU C-DE.09.B.00169。

分类:ECLASS-9.0、10.0.1、11.0均为27130807,ETIM 8.0,UNSPSC 21.0为EC000943,39121600。

环境产品合规性:符合REACH SVHC和中国RoHS标准,环境友好使用期限为50年。

附件:包括断开条、螺钉端子条、安装夹和屏蔽连接。
2807968 价格&库存

很抱歉,暂时无法提供与“2807968”相匹配的价格&库存,您可以联系我们找货

免费人工找货