0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2810395

2810395

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

  • 描述:

    REPEATER POWER SUPPLY

  • 数据手册
  • 价格&库存
2810395 数据手册
https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Configurable loop-powered temperature transducer for Pt 100 temperature sensors, configured via DIP switches, with spring-cage connection, not pre-configured. Replacement part: 2810308 MINI MCR-SL-PT100-LP-NC. Your advantages  2, 3 or 4-wire Pt 100 sensors  Highly-compact loop-powered temperature transducer for electrical isolation, conversion, amplification, and filtering of Pt 100 signals to create standard signals  Does not require additional auxiliary voltage  Error indication via diagnostic LED and analog signal  2-way isolation  Temperature measuring range of -150°C to +300°C  Supplied by an output loop  Input signals can be configured via DIP switches Key Commercial Data Packing unit 1 pc GTIN GTIN 4046356142472 Weight per Piece (excluding packing) 80.000 g Custom tariff number 85437090 Country of origin Germany 06/27/2020   Page 1 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Maximum altitude ≤ 2000 m Permissible humidity (operation) 5 % ... 95 % (non-condensing) Degree of protection IP20 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Input data Configurable/programmable Yes, unconfigured Sensor types (RTD) that can be used Pt 100 (IEC 60751/EN 60751) Sensor input current 1 mA (constant) Connection technology 2, 3, 4-wire Output data Number of outputs 1 Configurable/programmable Yes, unconfigured Current output signal 4 mA ... 20 mA 20 mA ... 4 mA Max. output current 23 mA (output limit) Load/output load current output (Usupply - 12 V) / 22 mA Ripple < 20 mVPP (at 500 Ω) Power supply Designation Loop-powered Supply voltage range 12 V DC ... 30 V DC Max. current consumption < 4.5 mA (without signal current) Power consumption < 150 mW (without signal current) Connection data 06/27/2020   Page 2 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Technical data Connection data Connection method Spring-cage connection Stripping length 8 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 12 General Transmission error in the set measuring range ((90 K / set measuring range [K]) + 0.05)% Transmission error in the full measuring range ≤ 0,25 % Maximum temperature coefficient < 0.02 %/K Linearity error < 0.05 % (for full measuring range) Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 30 V AC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T4 Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 5% Designation Fast transients (burst) Standards/regulations EN 61000-4-4 06/27/2020   Page 3 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Technical data EMC data Typical deviation from the measuring range final value 5% Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 5% Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T4 Environmental Product Compliance REACh SVHC Lead 7439-92-1 China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 06/27/2020   Page 4 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Application drawing 06/27/2020   Page 5 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Block diagram 06/27/2020   Page 6 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Dimensional drawing Classifications eCl@ss eCl@ss 4.0 27200200 eCl@ss 4.1 27200200 eCl@ss 5.0 27200200 eCl@ss 5.1 27200200 eCl@ss 6.0 27200200 eCl@ss 7.0 27200206 eCl@ss 8.0 27200206 eCl@ss 9.0 27210129 06/27/2020   Page 7 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Classifications ETIM ETIM 2.0 EC001446 ETIM 3.0 EC001446 ETIM 4.0 EC001446 ETIM 5.0 EC001446 ETIM 6.0 EC002919 ETIM 7.0 EC002919 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 41112105 UNSPSC 19.0 41112105 Approvals Approvals Approvals UL Recognized / cUL Recognized / cULus Recognized Ex Approvals ATEX / UL Listed / cUL Listed / EAC Ex / cULus Listed Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 06/27/2020   Page 8 / 9 https://www.phoenixcontact.com/us/products/2810395 Temperature measuring transducer - MINI MCR-SL-PT100-LP-NCSP - 2810395 Approvals cULus Recognized       Phoenix Contact 2020 © - all rights reserved http://www.phoenixcontact.com 06/27/2020   Page 9 / 9
2810395 价格&库存

很抱歉,暂时无法提供与“2810395”相匹配的价格&库存,您可以联系我们找货

免费人工找货