MCR temperature measuring transducer, for thermocouples type J, K input: 0 - 400°C, 0 - 800°C, 0 - 1000°C, 0 1200°C, input electrically isolated, output signal 0..10 V
Key commercial data
Packing unit
1 pc
GTIN
Weight per Piece (excluding packing)
139.0 GRM
Custom tariff number
85437090
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
17.5 mm
Height
99 mm
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 65 °C
Input data
Configurable/programmable
Yes
Sensor types that can be used (TC)
J, K
10/17/2014 Page 1 / 4
https://www.phoenixcontact.com/us/products/2810515
Thermocouple measuring transducer - MCR-TE-JK-U-E - 2810515
Technical data
Input data
Temperature measuring range
0 °C ... 400 °C
0 °C ... 800 °C
0 °C ... 1000 °C
0 °C ... 1200 °C
Output data
Output name
Voltage output
Configurable/programmable
Yes
Voltage output signal
0 V ... 10 V
Max. output voltage
15 V
Output voltage with wire break
> 11 V
Load/output load voltage output
≥ 10 kΩ
Power supply
Supply voltage range
18 V DC ... 30 V DC
Max. current consumption
20 mA
Connection data
Connection method
Pluggable screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
14
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Stripping length
8 mm
Screw thread
M3
General
Maximum transmission error
≤ 1.2 % (of end value, for type K)
< 2 % (of end value, for type J, 0 °C ... 400°C and 0 °C ... 800°C)
< 2.5 % (of end value, for type J, 0 °C ... 1000°C and 0 °C ... 1200°C)
Maximum temperature coefficient
< 0.02 %/K
Cold point error, max.
±4K
Typical cold point errors
± 2.5 K
Limit frequency (3 dB)
30 Hz
Alignment zero
± 60 K
Alignment span
± 5 % (of final value)
Step response (10-90%)
approx. 11 ms
10/17/2014 Page 2 / 4
https://www.phoenixcontact.com/us/products/2810515
Thermocouple measuring transducer - MCR-TE-JK-U-E - 2810515
Technical data
General
Test voltage input/output
1.5 kV (50 Hz, 1 min.)
Test voltage input/power supply
1.5 kV (50 Hz, 1 min.)
Color
green
Housing material
Polyamide PA non-reinforced
Mounting position
any
Conformance
CE-compliant
UL, USA / Canada
cULus
Classifications
eCl@ss
eCl@ss 4.0
27200206
eCl@ss 4.1
27200206
eCl@ss 5.0
27200206
eCl@ss 5.1
27200206
eCl@ss 6.0
27200206
eCl@ss 7.0
27200206
ETIM
ETIM 2.0
EC001446
ETIM 3.0
EC001446
ETIM 4.0
EC001446
ETIM 5.0
EC001446
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / GOST / cULus Recognized
10/17/2014 Page 3 / 4
https://www.phoenixcontact.com/us/products/2810515
Thermocouple measuring transducer - MCR-TE-JK-U-E - 2810515
Approvals
Ex Approvals
Approvals submitted
Approval details
UL Recognized
cUL Recognized
GOST
cULus Recognized
Drawings
Dimensioned drawing
99
Circuit diagram
17,5
OUT
IN
1
Sensor (+)
(-) 2
3
shield
7
8
9
U
=
+24V DC
GND
12 GND
10
=
114,5
OUT I/U
GND
GND
11
MM
Phoenix Contact 2014 © - all rights reserved