0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2810612

2810612

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    ISOLATED AMP 2 CHAN DIN RAIL

  • 数据手册
  • 价格&库存
2810612 数据手册
https://www.phoenixcontact.com/us/products/2810612 Current transducers - MACX MCR-SL-CAC- 5-I - 2810612 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Current measuring transducer for 1 A and 5 A AC, the output signal 0...20 mA or 4...20 mA, can be configured using a DIP switch with an operating mode indication through an LED The figure shows 2810625 MACX MCR-SL-CAC-5-I-UP Product Description The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals 0...20 mA or 4...20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output current. The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC. The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC. Product Features ■ Input/output can be configured via DIP switches Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 176.8 g Custom tariff number 85437090 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 104 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C (-4°F ... 149°F) 05/16/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2810612 Current transducers - MACX MCR-SL-CAC- 5-I - 2810612 Technical data Ambient conditions Ambient temperature (storage/transport) -40 °C ... 85 °C (-40°F...185°F) Maximum altitude 2000 m Degree of protection IP20 Input data Configurable/programmable Via DIP switches Operate threshold 0.3 % (1 A) 0.45 % (5 A) Setting range for min. input current 0 A AC ... 1 A (configurable) Setting range for max. input current 0 A AC ... 5 A (configurable) Overload capacity 2 x IN (continuous) Surge strength 20 x IN (1 s) Nominal frequency fN 50 Hz Frequency measuring range 45 Hz ... 65 Hz Connection method Screw terminal block Output data Output name Current output Configurable/programmable Via DIP switches Current output signal 0 mA ... 20 mA (configurable) 4 mA ... 20 mA (configurable) Max. output current 25 mA Load/output load current output < 500 Ω (at 20 mA) Status display LED red (error), LED green (ready) Switching output Output name No switching output Power supply Nominal supply voltage 24 V DC (-20 %...+25 %) Supply voltage range 19.2 V DC ... 30 V DC Max. current consumption < 32 mA (at UB=24 V DC, IOUT=20 mA) Power consumption < 0.9 W (at UB=24 V DC, IOUT=20 mA) Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 05/16/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2810612 Current transducers - MACX MCR-SL-CAC- 5-I - 2810612 Technical data Connection data Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 8 mm Screw thread M3 General Maximum transmission error ≤ 0.5 % (of nominal range value under nominal conditions) Maximum temperature coefficient < 0.02 %/K Temperature coefficient, typical < 0.015 %/K Step response (10-90%) max. 300 ms typ. 200 ms Overvoltage category II Degree of pollution 2 Test voltage input/output 4 kV (50 Hz, 1 min.) Test voltage output/power supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material Polyamide PA non-reinforced Mounting position any Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized 05/16/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2810612 Current transducers - MACX MCR-SL-CAC- 5-I - 2810612 Classifications eCl@ss eCl@ss 4.0 27200303 eCl@ss 4.1 27200303 eCl@ss 5.0 27200303 eCl@ss 5.1 27200303 eCl@ss 6.0 27200303 eCl@ss 7.0 27142316 eCl@ss 8.0 27210123 eCl@ss 9.0 27210123 ETIM ETIM 2.0 EC001440 ETIM 3.0 EC001440 ETIM 4.0 EC001440 ETIM 5.0 EC002475 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / cULus Recognized Ex Approvals ATEX Approvals submitted Approval details 05/16/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2810612 Current transducers - MACX MCR-SL-CAC- 5-I - 2810612 Approvals UL Recognized  cUL Recognized  EAC  cULus Recognized  Drawings Application drawing Dimensional drawing 104 22,5 7 0...20mA 114,5 5A 24V 00 10 A Mains voltage Current measurement Circuit diagram L(+) 1.1 OUT L(+) 1.2 3.1 N(-) 1.3 3.2 GND N(-) 1.4 3.3 GND 3.4 GND 4.1 1A OUT1 4.2 5A 4.3 NC 4.4 IN 05/16/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2810612 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 05/16/2016   Page 6 / 6
2810612 价格&库存

很抱歉,暂时无法提供与“2810612”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2810612
    •  国内价格
    • 1+2586.31809

    库存:6