https://www.phoenixcontact.com/us/products/2810612
Current transducers - MACX MCR-SL-CAC- 5-I - 2810612
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Current measuring transducer for 1 A and 5 A AC, the output signal 0...20 mA or 4...20 mA, can be configured
using a DIP switch with an operating mode indication through an LED
The figure shows 2810625 MACX
MCR-SL-CAC-5-I-UP
Product Description
The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals
0...20 mA or 4...20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output
current.
The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC.
The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC.
Product Features
■
Input/output can be configured via DIP switches
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
176.8 g
Custom tariff number
85437090
Country of origin
Germany
Technical data
Dimensions
Width
22.5 mm
Height
104 mm
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 65 °C (-4°F ... 149°F)
05/16/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/2810612
Current transducers - MACX MCR-SL-CAC- 5-I - 2810612
Technical data
Ambient conditions
Ambient temperature (storage/transport)
-40 °C ... 85 °C (-40°F...185°F)
Maximum altitude
2000 m
Degree of protection
IP20
Input data
Configurable/programmable
Via DIP switches
Operate threshold
0.3 % (1 A)
0.45 % (5 A)
Setting range for min. input current
0 A AC ... 1 A (configurable)
Setting range for max. input current
0 A AC ... 5 A (configurable)
Overload capacity
2 x IN (continuous)
Surge strength
20 x IN (1 s)
Nominal frequency fN
50 Hz
Frequency measuring range
45 Hz ... 65 Hz
Connection method
Screw terminal block
Output data
Output name
Current output
Configurable/programmable
Via DIP switches
Current output signal
0 mA ... 20 mA (configurable)
4 mA ... 20 mA (configurable)
Max. output current
25 mA
Load/output load current output
< 500 Ω (at 20 mA)
Status display
LED red (error), LED green (ready)
Switching output
Output name
No switching output
Power supply
Nominal supply voltage
24 V DC (-20 %...+25 %)
Supply voltage range
19.2 V DC ... 30 V DC
Max. current consumption
< 32 mA (at UB=24 V DC, IOUT=20 mA)
Power consumption
< 0.9 W (at UB=24 V DC, IOUT=20 mA)
Connection data
Connection method
Screw connection
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
05/16/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/2810612
Current transducers - MACX MCR-SL-CAC- 5-I - 2810612
Technical data
Connection data
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Stripping length
8 mm
Screw thread
M3
General
Maximum transmission error
≤ 0.5 % (of nominal range value under nominal conditions)
Maximum temperature coefficient
< 0.02 %/K
Temperature coefficient, typical
< 0.015 %/K
Step response (10-90%)
max. 300 ms
typ. 200 ms
Overvoltage category
II
Degree of pollution
2
Test voltage input/output
4 kV (50 Hz, 1 min.)
Test voltage output/power supply
1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC
Noise emission
EN 61000-6-4
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Color
green
Housing material
Polyamide PA non-reinforced
Mounting position
any
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada
UL 508 Recognized
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC Directive 2004/108/EC
Noise emission
EN 61000-6-4
Connection in acc. with standard
CUL
Standards/regulations
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Conformance
CE-compliant
ATEX
II 3 G Ex nA IIC T4 Gc X
UL, USA / Canada
UL 508 Recognized
05/16/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/2810612
Current transducers - MACX MCR-SL-CAC- 5-I - 2810612
Classifications
eCl@ss
eCl@ss 4.0
27200303
eCl@ss 4.1
27200303
eCl@ss 5.0
27200303
eCl@ss 5.1
27200303
eCl@ss 6.0
27200303
eCl@ss 7.0
27142316
eCl@ss 8.0
27210123
eCl@ss 9.0
27210123
ETIM
ETIM 2.0
EC001440
ETIM 3.0
EC001440
ETIM 4.0
EC001440
ETIM 5.0
EC002475
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals
ATEX
Approvals submitted
Approval details
05/16/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/2810612
Current transducers - MACX MCR-SL-CAC- 5-I - 2810612
Approvals
UL Recognized
cUL Recognized
EAC
cULus Recognized
Drawings
Application drawing
Dimensional drawing
104
22,5 7
0...20mA
114,5
5A
24V
00
10
A
Mains voltage
Current measurement
Circuit diagram
L(+)
1.1
OUT
L(+) 1.2
3.1
N(-)
1.3
3.2
GND
N(-)
1.4
3.3
GND
3.4
GND
4.1
1A
OUT1
4.2
5A
4.3
NC
4.4
IN
05/16/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/2810612
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
05/16/2016 Page 6 / 6