Current measuring transducer for 1 A and 5 A AC, the output signal 0...20 mA or 4...20 mA, can
be configured using a DIP switch with an operating mode indication through an LED
Product Description
The MACX MCR-SL-CAC-5-I(-UP) current measuring transducers convert sinusoidal alternating currents of 1 A or 5 A into standard analog signals
0...20 mA or 4...20 mA. The DIP switches, which can be accessed on the upper side of the housing, can be used to configure the input and output
current.
The MACX MCR-SL-CAC-5-I current transducer contains a supply voltage range of 19.2 V DC to 30 V DC.
The MACX MCR-SL-CAC-5-I current transducer contains a long range version with a supply voltage range of 19.2 V AC/DC to 253 V AC/DC.
Your advantages
• Input/output can be configured via DIP switches
Commercial Data
Item number
2810625
Packing unit
1 pc
Minimum order quantity
1 pc
Sales Key
C04
Product Key
CK4A21
Catalog Page
Page 234 (C-5-2019)
GTIN
4046356153782
Weight per Piece (including packing)
223.9 g
Weight per Piece (excluding packing)
181.6 g
Customs tariff number
85437090
Country of origin
DE
Oct 27, 2022, 6:49 PM
Page 1 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Technical Data
Notes
Utilization restriction
EMC note
EMC: class A product, see manufacturer's declaration in the
download area
Product properties
Product type
Current transducer
Insulation characteristics
Overvoltage category
III
Pollution degree
2
Electrical properties
Maximum power dissipation for nominal condition
< 0.9 W (24 V DC)
< 3.4 W (230 V AC)
Protective circuit
Surge protection; 35 V suppressor diode
Step response (10-90%)
≤ 300 ms
200 ms
Maximum temperature coefficient
< 0.02 %/K
Temperature coefficient, typical
< 0.015 %/K
Maximum transmission error
≤ 0.5 % (of nominal range value under nominal conditions)
Reverse polarity protection
yes
Rated insulation voltage
300 V AC (to earth)
Electrical isolation Input/output
Test voltage
4 kV AC (50 Hz, 60 s)
Electrical isolation Output/supply
Test voltage
2 kV AC (50 Hz, 60 s)
Supply
Supply voltage range
19.2 V AC/DC ... 253 V AC/DC
Max. current consumption
< 33 mA (24 V DC)
Power consumption
< 0.8 W (24 V DC)
Input data
Measurement
Configurable/programmable
Via DIP switches
Input current range
0 A AC ... 1 A AC (configurable)
0 A AC ... 5 A AC (configurable)
Voltage input signal
≤ 300 V AC
Input impedance
< 50 mΩ
Overload capacity
2 x IN (continuous)
Oct 27, 2022, 6:49 PM
Page 2 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Surge strength
20 x IN (1 s)
Nominal frequency fN
50 Hz
Frequency measuring range
45 Hz ... 65 Hz
Curve type
Sine
Output data
Signal: Current
Configurable/programmable
Via DIP switches
Non-load voltage
15 V
Current output signal
0 mA ... 20 mA (configurable)
4 mA ... 20 mA (configurable)
Max. current output signal
25 mA
Load/output load current output
< 500 Ω (20 mA)
Ripple
< 10 mVPP (500 Ω / 20 mA)
Status display
LED red (error), LED green (ready)
Connection data
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Interfaces
Data communication (bypass)
Limit frequency (3 dB)
approx. 3 Hz
Dimensions
Dimensional drawing
Width
22.5 mm
Height
104 mm
Depth
114.5 mm
Material specifications
Housing material
Polyamide PA non-reinforced
Environmental and real-life conditions
Oct 27, 2022, 6:49 PM
Page 3 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 65 °C
-4 °F ... 149 °F
Ambient temperature (storage/transport)
-40 °C ... 85 °C (-40 °F ... 185 °F)
Altitude
≤ 2000 m
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Approval data
CE
Certificate
CE-compliant
ATEX
Identification
II 3 G Ex nA IIC T4 Gc X
UKCA Ex (UKEX)
Identification
Certificate
II 3 G Ex nA IIC T4 Gc
PxCIF21UKEX2810638X
UL, USA / Canada
Identification
UL 508 Recognized
EAC Ex
Identification
Certificate
2Ex nA IIC T4 Gc
BY/112 02.01 TP012 103.01 00078
EMC data
Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61000-6-4
Noise immunity
EN 61000-6-2
Note
When being exposed to interference, there may be minimal
deviations.
Electrostatic discharge
Standards/regulations
EN 61000-4-2
Electromagnetic HF field
Standards/regulations
EN 61000-4-3
Electromagnetic HF field
Comments
Criterion A
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Fast transients (burst)
Comments
Criterion B
Oct 27, 2022, 6:49 PM
Page 4 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Surge current load (surge)
Standards/regulations
EN 61000-4-5
Surge current load (surge)
Comments
Criterion B
Conducted interference
Standards/regulations
EN 61000-4-6
Mounting
Mounting type
DIN rail mounting
Mounting position
any
Oct 27, 2022, 6:49 PM
Page 5 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Drawings
Dimensional drawing
22,5 7
114,5
104
Oct 27, 2022, 6:49 PM
Page 6 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Application drawing
0...20mA
5A
24V
00
10
A
Mains voltage
Current measurement
Oct 27, 2022, 6:49 PM
Page 7 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Approvals
cUL Recognized
UL Recognized
Approval ID: FILE E 238705
Approval ID: FILE E 238705
EAC Ex
Approval ID: RU C-DE.AB72.B.02066
ATEX
Approval ID: 2810638_Ex-n
cULus Recognized
Oct 27, 2022, 6:49 PM
Page 8 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Classifications
ECLASS
ECLASS-9.0
27210123
ECLASS-10.0.1
27210123
ECLASS-11.0
27210123
ETIM
ETIM 8.0
EC002475
UNSPSC
UNSPSC 21.0
39121000
Oct 27, 2022, 6:49 PM
Page 9 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Environmental Product Compliance
REACh SVHC
Lead 7439-92-1
China RoHS
Environmentally Friendly Use Period = 50 years
For information on hazardous substances, refer to the
manufacturer’s declaration available under “Downloads”
Oct 27, 2022, 6:49 PM
Page 10 (11)
Current transducers - MACX MCR-SL-CAC- 5-I-UP
2810625
https://www.phoenixcontact.com/us/products/2810625
Accessories
DIN rail bus connectors
DIN rail bus connectors - ME 22,5 TBUS 1,5/ 5-ST-3,81 GY - 2201937
https://www.phoenixcontact.com/us/products/2201937
DIN rail connector, color: gray, nominal current: 8 A (parallel contacts), rated
voltage (III/2): 125 V, number of positions: 5, pitch: 3.81 mm, mounting: DIN rail
mounting, locking: without, mounting: without, type of packaging: packed in
cardboard, Item with gold-plated contacts, bus connectors for connecting with
electronics housings, 5 parallel contacts
Phoenix Contact 2022 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Oct 27, 2022, 6:49 PM
Page 11 (11)