2810780

2810780

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    3-WAY ISOLATING AMP 4-20MA

  • 数据手册
  • 价格&库存
2810780 数据手册
https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR 3-way isolating amplifier, with configurable input/output, for electrical isolation and conversion of analog signals in the mV range, single-pos. as well as 2-pos. with screw connection, pre-configured Product Features ■ ■ ■ ■ ■ ■ Power supply possible via the foot element (TBUS) Ideal for converting signals for shunt measurements Low power consumption Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of mV signals to create standard analog signals Up to 280 signal combinations can be configured using DIP switches 3-way isolation Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 80.0 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm 05/16/2016   Page 1 / 7 https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Technical data Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Maximum altitude ≤ 2000 m Degree of protection IP20 Input data Number of inputs 1 Configurable/programmable Yes, unconfigured Voltage input signal -50 mV ... 50 mV -60 mV ... 60 mV -75 mV ... 75 mV -80 mV ... 80 mV -100 mV ... 100 mV -120 mV ... 120 mV -150 mV ... 150 mV -200 mV ... 200 mV -240 mV ... 240 mV -300 mV ... 300 mV -500 mV ... 500 mV -600 mV ... 600 mV -750 mV ... 750 mV -800 mV ... 800 mV -1 V ... 1 V -1.2 V ... 1.2 V -1.5 V ... 1.5 V -2 V ... 2 V -2.4 V ... 2.4 V -3 V ... 3 V 0 mV ... 50 mV 0 mV ... 60 mV 0 mV ... 75 mV 0 mV ... 80 mV 0 mV ... 100 mV 0 mV ... 120 mV 0 mV ... 150 mV 0 mV ... 200 mV 0 mV ... 240 mV 0 mV ... 300 mV 05/16/2016   Page 2 / 7 https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Technical data Input data 0 mV ... 500 mV 0 mV ... 600 mV 0 mV ... 750 mV 0 mV ... 800 mV 0 V ... 1 V 0 V ... 1.2 V 0 V ... 1.5 V 0 V ... 2 V 0 V ... 2.4 V 0 V ... 3 V Max. input voltage approx. 3 V DC Input resistance of voltage input approx. 10 kΩ Output data Number of outputs 1 Configurable/programmable Yes, unconfigured Voltage output signal 0 V ... 10 V 2 V ... 10 V 0 V ... 5 V 1 V ... 5 V -10 V ... 10 V (The bi-polar output can be used only for bi-polar input signals.) -5 V ... 5 V (The bi-polar output can be used only for bi-polar input signals.) Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Load/output load voltage output ≥ 10 kΩ Load/output load current output < 500 Ω (at 20 mA) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC Max. current consumption < 25 mA Power consumption < 450 mW (Current output) Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 26 05/16/2016   Page 3 / 7 https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Technical data Connection data Conductor cross section AWG max. 12 Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 12 mm Screw thread M3 Connection method 2-wire General No. of channels 1 Maximum transmission error ≤ 0.2 % < 0.4 % (Without adjustment) Maximum temperature coefficient < 0.01 %/K Temperature coefficient, typical < 0.002 %/K Limit frequency (3 dB) 100 Hz / 30 Hz switchable Step response (10-90%) 3.5 ms (At 100 Hz) Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL GL EMC 2 D EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 6% 05/16/2016   Page 4 / 7 https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Technical data EMC data Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 6% Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 6% Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 applied for GL GL EMC 2 D Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 05/16/2016   Page 5 / 7 https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Classifications ETIM ETIM 2.0 EC001485 ETIM 3.0 EC001485 ETIM 4.0 EC001485 ETIM 5.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / GL / EAC / cULus Recognized Ex Approvals ATEX Approvals submitted Approval details UL Recognized  cUL Recognized  GL  05/16/2016   Page 6 / 7 https://www.phoenixcontact.com/us/products/2810780 Signal conditioner - MINI MCR-SL-SHUNT-UI-NC - 2810780 Approvals EAC  cULus Recognized  Drawings Application drawing Block diagram OUT IN Sensor / Field PLC / DCS G Controller OUT U M US IN + – IN U OUT U,I 5 + 5 2 – 2 GND 1 passive GND 2 6 6 – OUT ±...mV U/I GND1 + 1 active GND Shunt resistor 1 4-wire + 3 GND2 UB+ UB+ GND3 GND3 – 4 +24V GND 3 7 + GND 3 8 – 24V MINI MCR-SL-SHUNT-UI Battery +24V +24V GND 3 Power supply Zone 2 Monitoring of loading and unloading currents Dimensional drawing 6,2 102,5 93,1 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 05/16/2016   Page 7 / 7
2810780 价格&库存

很抱歉,暂时无法提供与“2810780”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2810780
  •  国内价格
  • 1+2145.77113

库存:4