2814744

2814744

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    Module

  • 描述:

  • 数据手册
  • 价格&库存
2814744 数据手册
https://www.phoenixcontact.com/us/products/2814744 Current transducers - MCR-S10-50-UI-SW-DCI-NC - 2814744 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR current measuring transducer, programmable and configurable, for measuring direct, alternating and distorted currents, with relay and transistor output, input current 0...10 to 0...50 A, unconfigured The illustration shows version MCRS-10-50-UI-DCI Product Features ■ ■ ■ 3-way isolation True r.m.s. value measurement Device can be set via DIP switches or MCR/PI-CONF-WIN configuration software Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 193.7 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 60 °C 03/07/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2814744 Current transducers - MCR-S10-50-UI-SW-DCI-NC - 2814744 Technical data Ambient conditions Ambient temperature (storage/transport) -40 °C ... 85 °C Degree of protection IP20 Input data Input Current measuring input Configurable/programmable Yes, unconfigured Input current range 0 A ... 55 A (AC/DC) Operate threshold 0.8 % (of measuring range nominal value 50 A) Setting range for min. input current 0 A ... 9.5 A Setting range for max. input current 0 A ... 55 A Impulse form AC, DC or distorted currents Overload capacity Depending on through connected conductor Surge strength Depending on through connected conductor Frequency measuring range 15 Hz ... 400 Hz Connection method Through connection, diameter 10.5 mm Output data Output name Voltage output / current output Configurable/programmable Yes, unconfigured Voltage output signal 0 V ... 10 V 2 V ... 10 V -10 V ... 10 V 0 V ... 5 V 1 V ... 5 V -5 V ... 5 V 10 V ... 0 V 10 V ... 2 V 10 V ... -10 V 5 V ... 0 V 5 V ... 1 V 5 V ... -5 V Current output signal 0 mA ... 0.02 A 4 mA ... 0.02 A 20 mA ... 0 A 20 mA ... 0.004 A Load/output load voltage output > 10 kΩ Load/output load current output < 500 Ω Switching output 03/07/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2814744 Current transducers - MCR-S10-50-UI-SW-DCI-NC - 2814744 Technical data Switching output Output name Relay output Contact type 1 PDT Contact material AgSnO, hard gold-plated Maximum switching voltage 30 V AC 36 V DC 250 V AC (when the gold layer is destroyed) Limiting continuous current 50 mA 2 A (when the gold layer is destroyed) Output name Transistor output, pnp Output voltage range 19 V ... 29 V (supply voltage - 1 V) Continuous load current 80 mA (Not short-circuit proof) Setting range of the threshold value 1 % ... 110 % Setting range of the response delay 0.1 s ... 20 s Status display Yellow LED Power supply Supply voltage range 20 V DC ... 30 V DC Max. current consumption < 50 mA (without load) Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 14 Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 8 mm Screw thread M3 General Maximum transmission error < 0.5 % (of nominal range value under nominal conditions) Temperature coefficient, typical < 0.025 %/K Step response (10-90%) 330 ms (with AC) 40 ms (with DC) Status display Green LED Overvoltage category III Degree of pollution 2 Rated insulation voltage 300 V AC (to earth) 03/07/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2814744 Current transducers - MCR-S10-50-UI-SW-DCI-NC - 2814744 Technical data General Test voltage input/output 4 kV (50 Hz, 1 min.) Test voltage input/power supply 4 kV (50 Hz, 1 min.) Test voltage output/power supply 500 V (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Color green Housing material Polyamide PA non-reinforced Mounting position any Conformance CE-compliant UL, USA / Canada Class I, Zone 2, AEx nC IIC T6, Ex nC IIC T6 Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Connection in acc. with standard CUL Low Voltage Directive Conformance with Low Voltage Directive 2006/95/EC Conformance CE-compliant UL, USA / Canada Class I, Zone 2, AEx nC IIC T6, Ex nC IIC T6 Classifications eCl@ss eCl@ss 4.0 27200303 eCl@ss 4.1 27200303 eCl@ss 5.0 27200303 eCl@ss 5.1 27200303 eCl@ss 6.0 27200303 eCl@ss 8.0 27210123 eCl@ss 9.0 27210123 ETIM ETIM 2.0 EC001440 ETIM 3.0 EC001440 ETIM 4.0 EC001440 ETIM 5.0 EC002475 03/07/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2814744 Current transducers - MCR-S10-50-UI-SW-DCI-NC - 2814744 Classifications UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / EAC / cULus Recognized Ex Approvals UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details UL Recognized  cUL Recognized  EAC  cULus Recognized  Drawings 03/07/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2814744 Current transducers - MCR-S10-50-UI-SW-DCI-NC - 2814744 Dimensional drawing 22,5 ADC IN 12 1 11 2 14 3 NC 4 OUT SET TIME POINT ZERO 114,5 DAC µC SPAN 99 Circuit diagram OUT I DAC U Po wer = 9 O UT I 10 O UT U 11 GND 2 12 GND 2 13 24VDC 14 GND 1 15 SW 16 GND 1 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/07/2016   Page 6 / 6
2814744 价格&库存

很抱歉,暂时无法提供与“2814744”相匹配的价格&库存,您可以联系我们找货

免费人工找货