0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2814867

2814867

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    SIGNAL MULTIPLIER 4-WAY SPLITTER

  • 数据手册
  • 价格&库存
2814867 数据手册
Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. MCR signal multiplier, for doubling and electrical isolation of analog signals, unconfigured Your advantages • Calibrated selectable input and output signals • 4-way isolation Commercial Data Item number 2814867 Packing unit 1 pc Minimum order quantity 1 pc Note Made to Order (non-returnable) Sales Key C01 Product Key CK1811 Catalog Page Page 130 (C-7-2015) GTIN 4017918820336 Weight per Piece (including packing) 137.6 g Weight per Piece (excluding packing) 117.2 g Customs tariff number 85437090 Country of origin DE Oct 27, 2022, 7:25 AM Page 1 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Technical Data Product properties Product type Signal duplicator No. of channels 2 Electrical properties No. of channels 2 (1 inputs, 2 outputs) Electrical isolation between input and output yes Limit frequency (3 dB) 30 Hz Maximum power dissipation for nominal condition 15 mW Test voltage, input/output/supply 1.5 kV AC (50 Hz, 60 s) Protective circuit Transient protection Step response (10-90%) 12 ms Maximum temperature coefficient < 0.015 %/K Temperature coefficient, typical 0.0075 %/K Maximum transmission error ≤ 0.15 % (of final value) Transmission error, typical 0.05 % (of final value) Supply Supply voltage range 20 V DC ... 30 V DC Max. current consumption < 25 mA Input data Signal: Description of the input Current input Number of inputs 1 Configurable/programmable Yes, unconfigured Current input signal 0 mA ... 24 mA (freely selectable in 0.1 mA steps) Max. current input signal 50 mA Input resistance current input 50 Ω Voltage measuring range min. 4 V Current measuring range min. 8 mA Signal: Description of the input Voltage input Configurable/programmable Yes, unconfigured Voltage input signal 0 V ... 12 V (freely selectable in 0.1 V steps) Max. voltage input signal 30 V Input resistance of voltage input 200 kΩ Voltage measuring range min. 4 V Current measuring range min. 8 mA Output data Oct 27, 2022, 7:25 AM Page 2 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Signal: Number of outputs 2 Configurable/programmable Yes, unconfigured Voltage output signal 0 V DC ... 10 V DC 2 V DC ... 10 V DC 0 V DC ... 5 V DC 1 V DC ... 5 V DC Current output signal see order key / configuration table Max. current output signal 35 mA Load/output load current output ≤ 600 Ω Signal: Configurable/programmable Yes, unconfigured Voltage output signal see order key / configuration table Max. voltage output signal 15 V Load/output load voltage output ≥ 10 kΩ Connection data Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Dimensions Dimensional drawing Width 17.5 mm Height 99 mm Depth 114.5 mm Material specifications Housing material Polyamide PA non-reinforced Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -25 °C ... 55 °C Oct 27, 2022, 7:25 AM Page 3 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Approval data CE Certificate CE-compliant UL, USA / Canada Identification Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations Mounting Mounting type DIN rail mounting Mounting position any Oct 27, 2022, 7:25 AM Page 4 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Drawings Dimensional drawing 17,5 114,5 99 Circuit diagram OUT OUT I2 1 OUT U2 2 GND 2 3 IN I 4 IN U 5 GND 3 6 A A IN D OUT D A 7 OUT I1 8 OUT U1 9 GND 1 +24V DC 11 GND 4 12 GND 4 10 D Oct 27, 2022, 7:25 AM Page 5 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Application drawing 0...20mA 24V 0...20mA IN I 5 U 6 GND 3 1 2 3 POWER 4 MCR-FL-C-UI-2UI-DCI OUT 2 I2 U2 GND 2 OUT 1 I 7 POWER +24V 10 U1 8 GND 4 11 GND 1 9 GND 4 12 0...10V 15m3 24V Application example: - Level measurement with subsequent signal multiplication 1 = filling level sensor 2 = control 3 = mains voltage Oct 27, 2022, 7:25 AM Page 6 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Classifications ECLASS ECLASS-9.0 27210120 ECLASS-10.0.1 27210120 Oct 27, 2022, 7:25 AM Page 7 (8) Signal conditioner - MCR-FL-C-UI-2UI-DCI-NC 2814867 https://www.phoenixcontact.com/us/products/2814867 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Phoenix Contact 2022 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Oct 27, 2022, 7:25 AM Page 8 (8)
2814867 价格&库存

很抱歉,暂时无法提供与“2814867”相匹配的价格&库存,您可以联系我们找货

免费人工找货