https://www.phoenixcontact.com/us/products/2834708
Relay Module - PR2-RSP3-LV-120AC/2X21 - 2834708
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Preassembled relay modules with spring-cage connection, consisting of a relay base, industrial relay with
integrated LED and engage/disengage manual actuate lever, varistor protective module, and retaining bracket.
Input voltage: 120 V AC, two PDTs, 10 A
The figure shows the 24 V DC
version
Product Features
■
■
■
■
■
Relay with detectable manual operation and status LED
With DC types, freewheeling diode is integrated in relay
Mechanical switch position indicator
Logical contact arrangement thanks to 1/3-level relay base
4 PDT types with multi-layer gold contacts
Key Commercial Data
Packing unit
1 pc
Minimum order quantity
5 pc
Weight per Piece (excluding packing)
140.0 g
Custom tariff number
85364900
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
31 mm
Height
95 mm
Depth
84 mm
Ambient conditions
03/15/2016 Page 1 / 6
https://www.phoenixcontact.com/us/products/2834708
Relay Module - PR2-RSP3-LV-120AC/2X21 - 2834708
Technical data
Ambient conditions
Ambient temperature (operation)
-25 °C ... 60 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Coil side
Nominal input voltage UN
120 V AC
Typical input current at UN
11 mA (at 50 Hz)
9 mA (At 60 Hz)
Typical response time
4 ms ... 10 ms
Typical release time range
3 ms ... 12 ms
Protective circuit
Varistor
Operating voltage display
LED red
Contact side
Contact type
2 PDT
Contact material
Ag
Maximum switching voltage
250 V AC/DC
Minimum switching voltage
5V
Min. switching current
1 mA
Maximum inrush current
20 A (15 ms)
Limiting continuous current
10 A
Interrupting rating (ohmic load) max.
240 W (at 24 V DC)
160 W (at 48 V DC)
110 W (at 60 V DC)
72 W (at 110 V DC)
130 W (at 220 V DC)
2500 VA (for 250 V AC)
General
Test voltage relay winding/relay contact
2 kV (50 Hz, 1 min.)
Test voltage relay contact/relay contact
2 kV (50 Hz, 1 min.)
Operating mode
100% operating factor
Mechanical service life
5 x 10 cycles
Standards/regulations
IEC 60664
7
EN 50178
IEC 62103
Degree of pollution
3
Overvoltage category
II
Mounting position
any
Assembly instructions
In rows with zero spacing
03/15/2016 Page 2 / 6
https://www.phoenixcontact.com/us/products/2834708
Relay Module - PR2-RSP3-LV-120AC/2X21 - 2834708
Technical data
Connection data input side
Connection name
Coil side
Connection method
Spring-cage connection
Stripping length
12 mm
Conductor cross section solid
0.2 mm² ... 1.5 mm²
Conductor cross section flexible
0.2 mm² ... 1.5 mm²
Conductor cross section AWG
24 ... 16
Standards and Regulations
Standards/regulations
IEC 60664
EN 50178
IEC 62103
Degree of pollution
3
Overvoltage category
II
Articles in set
Relay socket - PR2-BSP3/4X21 - 2833589
Relay socket PR2-B, for industrial relay REL-IR with 2 or 4 PDT, 1/3-level version, spring-cage connections, connection
facility for input/interference suppression modules, for mounting on NS 35/7.5
Single relay - REL-IR/L-120AC/2X21 - 2834067
Plug-in industrial relay with power contacts, 2 PDTs, test button, status LED, mechanical switch setting display, input
voltage: 120 V AC
Plug-in module - V-120-230UC - 2833880
Plug-in module, for mounting on PR1 and PR2, with varistor, input voltage: 120-230 V AC/DC ± 20%
03/15/2016 Page 3 / 6
https://www.phoenixcontact.com/us/products/2834708
Relay Module - PR2-RSP3-LV-120AC/2X21 - 2834708
Articles in set
Relay retaining bracket - EL2-P35 - 2833592
Relay retaining bracket, with eject function and integrated equipment marking area (8 x 25 mm), to suit relay socket PR2,
for 35 mm high industrial relay
Classifications
eCl@ss
eCl@ss 4.0
27371102
eCl@ss 4.1
27371102
eCl@ss 5.0
27371603
eCl@ss 5.1
27371603
eCl@ss 6.0
27371603
eCl@ss 7.0
27371603
eCl@ss 8.0
27371601
eCl@ss 9.0
27371601
ETIM
ETIM 2.0
EC001456
ETIM 3.0
EC001456
ETIM 4.0
EC001456
ETIM 5.0
EC001437
UNSPSC
UNSPSC 6.01
30211917
UNSPSC 7.0901
39121516
UNSPSC 11
39121516
UNSPSC 12.01
39121516
UNSPSC 13.2
39121516
Approvals
Approvals
Approvals
EAC
03/15/2016 Page 4 / 6
https://www.phoenixcontact.com/us/products/2834708
Relay Module - PR2-RSP3-LV-120AC/2X21 - 2834708
Approvals
Ex Approvals
Approvals submitted
Approval details
EAC
Drawings
Circuit diagram
42
12
44
14
41
11
Diagram
1,8
Coil voltage U/UN
1,6
A2
A1
1,4
1,2
1
0,8
) The contacts 21, 22, 24 are connected to the
relay base connections 41, 42, 44.
0,6
0
10
20
30
40
50
60
70
Ambient temperature [°C]
80
Operating voltage range of relay Tu=Tcoil
Diagram
Diagram
20
1
10
6
4
Switching current [A]
Switching current [A]
20
2
2
1
0,5
0,3
0,2
10
6
4
10
20
1 Ohmic load
2 cos j = 0.4
AC interrupting rating
30
50 70 100
200
Switching voltage [V]
3
1
1
0,5
0,3
0,2
0,1
0,1
2
2
10
300
20
30
50 70 100
200
Switching voltage [V]
300
1 Ohmic load
2 ohmic load, contacts in series
3 L/R < 7 ms
DC interrupting rating
03/15/2016 Page 5 / 6
https://www.phoenixcontact.com/us/products/2834708
Relay Module - PR2-RSP3-LV-120AC/2X21 - 2834708
Diagram
Cycles
1
10
6
2
10
10
5
4
0
2
4
6
8
10
Switching current [A]
1 250 V AC, ohmic load
2 30 V DC, ohmic load
Electrical service life
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
03/15/2016 Page 6 / 6