Ex i resistance thermometer input: Converts signals of Pt 100 resistance thermometers installed
in the Ex zone and transfers a 4 mA ... 20 mA signal to a load in the safe zone. Freely
programmable. Galvanic 3-way isolation.
Commercial Data
Item number
2835066
Packing unit
1 pc
Minimum order quantity
1 pc
Note
Made to Order (non-returnable)
Sales Key
00
Product Key
CK3821
Catalog Page
Page 383 (IF-2007)
Weight per Piece (including packing)
107.5 g
Weight per Piece (excluding packing)
107.5 g
Customs tariff number
85437090
Country of origin
GB
Oct 27, 2022, 7:33 AM
Page 1 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Technical Data
Notes
Order information:
The electronics module is plugged into a basic terminal block.
Product properties
Product type
Temperature transmitter
Application
Temperature
No. of channels
1
Electrical properties
No. of channels
1
Maximum transmission error
< 0.1 % (of end value 20 mA, at 0 Ω ... 400 Ω input range, 20°C)
Electrical isolation Input/output
Electrical isolation
250 V
Electrical isolation Input/power supply
Electrical isolation
250 V
Electrical isolation Output/supply
Test voltage
1.5 kV AC (50 Hz, 60 s)
Supply
Supply voltage range
20 V DC ... 35 V DC
Max. current consumption
64 mA (24 V DC / 20 mA)
Power dissipation
1.5 W (24 V DC / 20 mA)
Input data
Measurement
Description of the input
Intrinsically safe
Configurable/programmable
Freely programmable, configured
Sensor types (RTD) that can be used
2 or 3-conductor Pt 100 sensors as well as resistance-type
sensors
Temperature measuring range
-200 °C ... 850 °C (Range depending on the sensor type)
Sensor type:
-200 °C ... 850 °C
Connection technology
2-, 3-conductor
Linear resistance measuring range
0 Ω ... 400 Ω (Minimum measuring range 10 Ω)
Measuring accuracy
±80 mΩ
Output data
Signal:
Output description
Current output
Current output signal
4 mA ... 20 mA
Load/output load current output
≤ 600 Ω
Oct 27, 2022, 7:33 AM
Page 2 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Behavior in the event of a sensor error
upscale, downscale or off, LED flashes
Measuring accuracy
±11 μA
Connection data
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Tightening torque
0.5 Nm ... 0.6 Nm
Ex data
Safety data
Max. output voltage Uo
6.6 V
Max. output current Io
27 mA
Max. output power Po
50 mW
Safety-related maximum voltage Um
250 V AC
IIB: Max. external inductivity Lo / Max. external capacitance Co
178.4 mH / 500 µF
IIC: Max. external inductivity Lo / Max. external capacitance Co
48.7 mH / 22 µF
LED signaling
Status display
Green LED, for power supply, flashes in the case of sensor
defect
Dimensions
Dimensional drawing
Width
12.4 mm
Height
145 mm
Depth
147 mm
Material specifications
Flammability rating according to UL 94
V0
Housing material
PBT and polyamide PA non-reinforced
Environmental and real-life conditions
Ambient conditions
Degree of protection
IP20
Ambient temperature (operation)
-20 °C ... 55 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Oct 27, 2022, 7:33 AM
Page 3 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Approval data
CE
Certificate
CE-compliant
ATEX
Identification
II (1) GD [EEx ia] IIC
UL, USA / Canada
Identification
cULus
Oct 27, 2022, 7:33 AM
Page 4 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Drawings
Block diagram
OUT
IN
+
4...20 mA
+-
UB+
UB-
- +- +
UB+
UB+
UB-
LF
PWR
STAT
UB-
PI-EX-RTD-I
Oct 27, 2022, 7:33 AM
Page 5 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Dimensional drawing
12,4
147
145
Oct 27, 2022, 7:33 AM
Page 6 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Classifications
ECLASS
ECLASS-9.0
27210129
ECLASS-10.0.1
27210129
ECLASS-11.0
27210129
Oct 27, 2022, 7:33 AM
Page 7 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Accessories
Basic terminal block
Basic terminal block - PI-EX-TB - 2835901
https://www.phoenixcontact.com/us/products/2835901
Ex base terminal block for intrinsically safe signals with knife disconnection and
test connections
Surge protection device
Surge protection device - TT-PI-EX-TB - 2858386
https://www.phoenixcontact.com/us/products/2858386
Intrinsically safe basic terminal block with isolating connector, test connections
and surge protection, for mounting on NS 35/7.5
Oct 27, 2022, 7:33 AM
Page 8 (9)
Signal converter - PI-EX-RTD-I
2835066
https://www.phoenixcontact.com/us/products/2835066
Basic terminal block
Basic terminal block - PI-EX-ES-1/3 - 2835325
https://www.phoenixcontact.com/us/products/2835325
Ex basic terminal block, with three terminal points to the field level (Ex area)
Phoenix Contact 2022 © - all rights reserved
https://www.phoenixcontact.com
Phoenix Contact USA
586 Fulling Mill Road
Middletown, PA 17057, United States
(+717) 944-1300
info@phoenixcon.com
Oct 27, 2022, 7:33 AM
Page 9 (9)
很抱歉,暂时无法提供与“2835066”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+4699.449931+611.05791