Ex-i thermocouple and mV input: Converts signals from thermocouples installed in Ex areas and mV sources and
transmits a 4-20 mA signal to a load in a safe area. Freely programmable. Galvanic 3-way isolation. Standard
configuration.
Key commercial data
Packing unit
1 PCE
Weight per Piece (excluding packing)
98.0 GRM
Custom tariff number
85437090
Country of origin
United Kingdom
Technical data
Dimensions
Width
12.4 mm
Height
145 mm
Depth
147 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 55 °C
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Degree of protection
IP20
Input data
Input
Intrinsically safe
Configurable/programmable
Freely programmable, unconfigured
Sensor types that can be used (TC)
J, K, T, E, R, S, B, N
Input signal range
-75 mV ... 75 mV (minimum measuring range span 3 mV)
Input accuracy
±15 μV or ± 0.05% of the input value, if this result is greater, at 20°C
12/4/13 Page 1 / 4
https://www.phoenixcontact.com/us/products/2835600
Signal converter - PI-EX-THC-I-NC - 2835600
Technical data
Output data
Signal output
Current output
Current output signal
4 mA ... 20 mA (output accuracy: ± 11 μA)
Load/output load current output
< 600 Ω
Behavior in the event of a sensor error
upscale, downscale or off, LED flashes
Power supply
Supply voltage range
20 V DC ... 35 V DC
Max. current consumption
64 mA (24 V DC/ 20 mA)
Power consumption
1.5 W (24 V DC/ 20 mA)
Connection data
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.2 mm²
Conductor cross section stranded max.
2.5 mm²
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
14
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
General
No. of channels
1
Maximum transmission error
< 0.12 % (of end value 20 mA, at 20°C, -75 mV ... 75 mV input range)
Temperature coefficient, typical
± 0.003 % (of input value /°C)
Typical cold point errors
1.5 °C
Status display
Green LED, for power supply, flashes in the case of sensor defect
Inflammability class according to UL 94
V0
Housing material
PBT and polyamide PA non-reinforced
Color
green
Name
Input/output
Electrical isolation
250 V
Name
Input/power supply
Electrical isolation
250 V
Name
Output/supply
Electrical isolation
1.5 kV AC (50 Hz, 1 min., test voltage)
Conformance
CE-compliant
ATEX
II (1) GD [EEx ia] IIC
UL, USA / Canada
"Intrinsically safe 'Entity'" Connection [AEx ia] IIC, [Ex ia] IIC
12/4/13 Page 2 / 4
https://www.phoenixcontact.com/us/products/2835600
Signal converter - PI-EX-THC-I-NC - 2835600
Technical data
Safety data
Max. output voltage Uo
1.1 V
Max. output current Io
4 mA
Max. output power Po
1 mW
Gas group
IIB
Max. external inductivity Lo
178.4 mH
Max. external capacity Co
500 µF
Gas group
IIC
Max. external inductivity Lo
48.7 mH
Max. external capacity Co
22 µF
Safety-related maximum voltage Um
250 V AC
Classifications
eCl@ss
eCl@ss 4.0
27200206
eCl@ss 4.1
27200206
eCl@ss 5.0
27200206
eCl@ss 5.1
27200206
eCl@ss 6.0
27200206
eCl@ss 7.0
27200206
eCl@ss 8.0
27200206
ETIM
ETIM 2.0
EC001446
ETIM 3.0
EC001446
ETIM 4.0
EC001446
ETIM 5.0
EC001446
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
Accessories
Additional products
12/4/13 Page 3 / 4
https://www.phoenixcontact.com/us/products/2835600
Signal converter - PI-EX-THC-I-NC - 2835600
Accessories
Basic terminal block - PI-EX-TB - 2835901
Ex base terminal block for intrinsically safe signals with knife disconnection and test connections
Surge protection device - TT-PI-EX-TB/T - 2858344
Intrinsically safe basic terminal block with isolating connector, test connections and surge protection, with additional
temperature measurement of the input terminal block for cold junction compensation, for mounting on NS 35/7.5
Drawings
Block diagram
Dimensioned drawing
145
OUT
IN
+
+
4...20 mA
+-
UB+
UB-
- +- +
UB+
UB+
UB-
LF
STAT
PWR
UB-
147
-
mV
-
12,4
PI-EX-THC-I
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com
12/4/13 Page 4 / 4