Inline positioning terminal, without accessories, 1 absolute encoder
input, 4 digital inputs 24 V DC, 4 digital outputs 24 V DC, 500 mA, 3wire connection method
Product notes
WEEE/RoHS-compliant since:
03/12/2007
Commercial data
GTIN (EAN)
4
017918
160807
sales group
K413
Pack
1 pcs.
Customs tariff
85389091
Catalog page information
Page 95 (AX-2007)
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Product description
The Inline absolute and incremental encoder terminals provide a simple solution for the positioning of drives.
The IB IL SSI terminal can be used for the connection of absolute encoders (single-turn or multi-turn). The IB IL INC
terminal can be used for the evaluation of incremental encoders (symmetrical or asymmetrical encoders). Both terminals
supply 5 V DC and 24 V DC for the connection of encoders and have four 24 V DC digital inputs and four 24 V DC digital
outputs, 500 mA.
The digital inputs connect limit switches and reference mark switches; the digital outputs set the transversing direction
and the transversing rate using control data.
The terminals are configured and parameterized via INTERBUS. The desired position values can then be set via the
control program. If the application allows it, position values can also be saved individually. The module accesses these
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 1 / 6
Feb 8, 2011
IB IL SSI Order No.: 2836340
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2836340
values independently after a request. The module constantly monitors the homing and sends status messages to the
control system. When an error occurs, the drive is immediately stopped.
The Inline positioning terminals can be labeled using hinged labeling fields. The fields have insert cards that can be
labeled individually to suit the application. Additionally, there is the ZB-FM-6... Zack strip for labeling the terminal points.
Technical data
Interfaces
Interface
Inline local bus
Type of connection
Inline data jumper
Power supply
I/O voltage
24 V DC (via voltage jumper)
Peripherals voltage range
19.2 V DC ... 30 V DC
Encoder supply voltage
5 V DC
24 V DC
Encoder supply current
500 mA
500 mA
Drawing encoder supply voltage
Main circuit UM
Electrical isolation
Test section
5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V
AC 50 Hz 1 min
5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V
AC 50 Hz 1 min
7.5 V supply (bus logics)/24 V supply (I/O) 500 V AC 50 Hz 1 min
7.5 V supply (bus logics) / functional earth ground of encoder
supply 500 V AC 50 Hz 1 min
24 V supply (I/O) / functional earth ground 500 V AC 50 Hz 1 min
24 V supply (I/O) / functional earth ground of encoder supply 500
V AC 50 Hz 1 min
Functional earth ground of encoder supply / Functional earth
ground 500 V AC 50 Hz 1 min
Absolute encoder input
Number of inputs
1
Adjustable resolution
26 Bit (maximum)
Transmission frequency
400 kHz
Inputs
Number of inputs
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
4
Page 2 / 6
Feb 8, 2011
IB IL SSI Order No.: 2836340
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2836340
Connection method
3-conductor
Input voltage
24 V DC
Outputs
Number of outputs
4
Connection method
3-conductor (shielded)
General data
Weight
130 g
Number of connectors
1
Width
48.8 mm
Height
119.8 mm
Depth
71.5 mm
Inline potential routing
Communications power UL
7.5 V DC (via voltage jumper)
Current consumption from UL
60 mA (maximum)
Main circuit supply UM
24 V DC (via voltage jumper)
Current consumption from UM
1 A (via voltage jumper)
Segment supply voltage US
24 V DC (via voltage jumper)
Current consumption from US
2 A (maximum)
Current consumption from UANA
0 A DC
Certificates / Approvals
Certification
CUL, GOST, UL
Accessories
Item
Designation
Description
2698452
IB IL SSI UM
User Manual, German, for Inline positioning terminals
2698465
IB IL SSI UM E
User Manual, English, for Inline positioning terminals
Literature
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 3 / 6
Feb 8, 2011
IB IL SSI Order No.: 2836340
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2836340
Marking
0809492
ESL 62X10
Insert strip for laser printer, lettering field: 62 x 10 mm
0809502
ESL 62X46
Insert strip for laser printer, lettering field: 62 x 46 mm
2727501
IB IL FIELD 2
Labeling field, width: 12.2 mm
2727515
IB IL FIELD 8
Labeling field, width: 48.8 mm
IB IL SSI/INC-PLSET
Connector set
Plug/Adapter
2732473
Diagrams/Drawings
Connection diagram
Block diagram
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 4 / 6
Feb 8, 2011
IB IL SSI Order No.: 2836340
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2836340
Dimensioned drawing
FAQs
•
Information on incremental value
With module IB IL SSI, the incremental value can be defined with the command A000 0000 (hex) (see chapter 5.9
of the manual). The complete command is as follows: OUT [0] 1010 00zz zzzz zzzz = Command + Data OUT [1]
nnnn nnnn nnnn nnnn = Data z = the counter of incremental value n = the denominator for the incremental value
IMPORTANT: The fraction resulting from numerator and denominator must always be less than or equal to 1!
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 5 / 6
Feb 8, 2011
IB IL SSI Order No.: 2836340
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2836340
Address
PHOENIX CONTACT Deutschland GmbH
Flachsmarktstr. 8
32825 Blomberg,Germany
Phone +49 5235 3 12000
Fax +49 5235 3 41200
http://www.phoenixcontact.de
© 2011 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Deutschland GmbH
http://www.phoenixcontact.de
Page 6 / 6
Feb 8, 2011
很抱歉,暂时无法提供与“2836340”相匹配的价格&库存,您可以联系我们找货
免费人工找货