0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2839211

2839211

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    Modular

  • 描述:

    TVS DIODE 5VWM MODULE

  • 数据手册
  • 价格&库存
2839211 数据手册
https://www.phoenixcontact.com/us/products/2839211 Surge protection plug - PT 4- 5DC-ST - 2839211 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Protective plug PT with protective circuit for a 4-core floating signal circuit. Nominal voltage: 5 V DC Product Features ■ ■ ■ ■ ■ Plugs can be checked with CHECKMASTER Maximum ease of maintenance thanks to the two-piece design Base element remains an integral part of the installation Consistent plug-in signal circuit protection Impedance-neutral disconnection of plug for test and maintenance purposes Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 24.84 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 45 mm Width 17.7 mm Depth 52 mm Horizontal pitch 1 Div. Complete module height 90 mm Complete module width 17.7 mm Complete module depth 65.5 mm 03/13/2016   Page 1 / 5 https://www.phoenixcontact.com/us/products/2839211 Surge protection plug - PT 4- 5DC-ST - 2839211 Technical data Ambient conditions Ambient temperature (operation) -40 °C ... 85 °C Degree of protection IP20 General Housing material PA 6.6 Flammability rating according to UL 94 V0 Color black Standards for cearances and creepage distances VDE 0110-1 IEC 60664-1 Mounting type On base element Type DIN rail module, two-section, divisible Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Protective circuit IEC test classification C1 C2 C3 D1 VDE requirement class C1 C2 C3 D1 Nominal voltage UN 5 V DC Maximum continuous voltage UC 6 V DC 4 V AC Maximum continuous voltage UC (wire-wire) 6 V DC 4 V AC Nominal current IN 2 A (80 °C) Operating effective current IC at UC ≤ 300 µA Residual current IPE ≤ 4 µA (Directly grounded) ≤ 1 µA (BE: 4+F) Nominal discharge current In (8/20) µs (Core-Core) 720 A Nominal discharge current In (8/20) µs (Core-Earth) 10 kA Total surge current (8/20) µs 20 kA Max. discharge current Imax (8/20) µs maximum (Core-Core) 720 A Max. discharge current Imax (8/20) µs maximum (Core-Earth) 10 kA 03/13/2016   Page 2 / 5 https://www.phoenixcontact.com/us/products/2839211 Surge protection plug - PT 4- 5DC-ST - 2839211 Technical data Protective circuit Nominal pulse current Ian (10/1000) µs (Core-Core) 160 A Impulse discharge current (10/350)˽µs, peak value limp 2.5 kA (per path) Output voltage limitation at 1 kV/µs (Core-Core) spike ≤ 13 V Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 450 V ≤ 1 kV (BE: 4+F) Output voltage limitation at 1 kV/µs (Core-Core) static ≤ 10 V Residual voltage at In (conductor-conductor) ≤ 40 V Residual voltage with Ian (10/1000)µs (conductor-conductor) ≤ 20 V Voltage protection level Up (core-core) ≤ 30 V (C1 (1 kV/500 A)) Voltage protection level Up (core-ground) ≤ 450 V ≤ 1 kV (BE: 4+F) Response time tA (Core-Core) ≤ 1 ns Response time tA (Core-Earth) ≤ 1 ns ≤ 100 ns Input attenuation aE, sym. 0.1 dB (≤ 250 kHz) Cut-off frequency fg (3 dB), sym. in 50 Ohm system typ. 1 MHz Surge protection fault message None Max. required back-up fuse 2 A (e.g. T ( IEC 127-2/III)) Impulse durability (conductor-conductor) C1 - 1 kV/500 A C3 - 100 A Impulse durability (conductor-ground) C2 - 10 kV/5 kA D1 - 2,5 kA Connection data Connection method Screw connection (in connection with the base element) Connection type IN PLUGTRAB plug-in system Connection type OUT PLUGTRAB plug-in system Screw thread M3 Tightening torque 0.5 Nm Stripping length 8 mm Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Standards and Regulations 03/13/2016   Page 3 / 5 https://www.phoenixcontact.com/us/products/2839211 Surge protection plug - PT 4- 5DC-ST - 2839211 Technical data Standards and Regulations Standards/regulations IEC 61643-21 DIN EN 61643-21 UL 497B Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130807 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals UL Listed / EAC / EAC 03/13/2016   Page 4 / 5 https://www.phoenixcontact.com/us/products/2839211 Surge protection plug - PT 4- 5DC-ST - 2839211 Approvals Ex Approvals UL Listed / cUL Listed / cULus Listed Approvals submitted Approval details UL Listed      Nominal current IN 2A Nominal voltage UN 5V EAC  EAC  Drawings Dimensional drawing Circuit diagram 90 44,8 1 2 5 6 7 8 OUT IN 12 11 51,5 65,5 9 3 * 10 4 The figure shows the complete module consisting of a base element and connector Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/13/2016   Page 5 / 5
2839211 价格&库存

很抱歉,暂时无法提供与“2839211”相匹配的价格&库存,您可以联系我们找货

免费人工找货