Attachment plug with replaceable surge protection for coaxial signal interfaces. Connection: N connector, malefemale, with adapter N connector to F connector.
Key commercial data
Packing unit
1 pc
Weight per Piece (excluding packing)
210.3 GRM
Custom tariff number
85363010
Country of origin
Germany
Technical data
Dimensions
Height
25 mm
Width
25 mm
Depth
72 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 80 °C
Degree of protection
IP20
General
Housing material
Nickel-plated brass
Color
nickel
Standards for air and creepage distances
IEC 60664-1
Surge voltage category
III
Pollution degree
2
Mounting type
Connection-specific intermediate plugging
Type
Attachment plug
Direction of action
Line-Shield/Earth Ground
10/30/2014 Page 1 / 4
https://www.phoenixcontact.com/us/products/2839541
Surge protection device - CF-UB-280DC-SB-SET - 2839541
Technical data
Protective circuit
IEC test classification
C2
C3
D1
VDE requirement class
C2
C3
D1
Maximum continuous operating voltage UC
280 V DC
195 V AC
Maximum continuous voltage UC (wire-ground)
280 V DC
195 V AC
Nominal current IN
5 A (25 °C)
Operating effective current IC at UC
≤ 1 µA
Nominal discharge current In (8/20) µs (Core-Earth)
20 kA
Nominal discharge current In (8/20) µs (Core-Shield)
20 kA
Total surge current (8/20) µs
20 kA
Total surge current (10/350) µs
2.5 kA
Max. discharge current Imax (8/20) µs maximum (Core-Shield)
20 kA
Nominal pulse current Ian (10/1000) µs (Core-Shield)
100 A
Output voltage limitation at 1 kV/µs (Core-Earth) spike
≤ 900 V
Output voltage limitation at 1 kV/µs (Core-Shield) spike
≤ 900 V
Voltage protection level UP (Core-Earth)
≤ 1.1 kV (C2 (10 kV/5 kA))
≤ 900 V (C1 - 1 kV/500 A)
≤ 1 kV (C3 - 25 A)
Voltage protection level UP (Core-Shield)
≤ 1.1 kV (C2 (10 kV/5 kA))
900 V (C1 - 1 kV/500 A)
≤ 1 kV (C3 - 25 A)
Response time tA (Core-Earth)
≤ 100 ns
Response time tA (Core-GND)
≤ 100 ns
Cut-off frequency fg (3 dB), asym. (shield) in 50 Ohm system
> 2 GHz
Permissible HF power Pmax at VSWR = xx (50 ohm system)
700 W (VSWR = 1.1)
200 W (VSWR = ∞)
Capacity (Core-Earth)
typ. 1.5 pF
Capacity asymmetrical (shield)
typ. 1.5 pF
Surge current resistance (conductor-ground)
C1 - 1 kV/500 A
C2 - 10 kV/5 kA
C3 - 100 A
D1 - 2,5 kA
10/30/2014 Page 2 / 4
https://www.phoenixcontact.com/us/products/2839541
Surge protection device - CF-UB-280DC-SB-SET - 2839541
Technical data
Connection data
Connection method
F connector
Connection type IN
F connector, male
Connection type OUT
F connector, female
Standards and Regulations
Standards/regulations
IEC 61643-21
Classifications
eCl@ss
eCl@ss 4.0
27140201
eCl@ss 4.1
27130801
eCl@ss 5.0
27130801
eCl@ss 5.1
27130801
eCl@ss 6.0
27130807
eCl@ss 7.0
27130807
eCl@ss 8.0
27130807
ETIM
ETIM 2.0
EC000943
ETIM 3.0
EC000943
ETIM 4.0
EC000943
ETIM 5.0
EC000943
UNSPSC
UNSPSC 6.01
30212010
UNSPSC 7.0901
39121610
UNSPSC 11
39121610
UNSPSC 12.01
39121610
UNSPSC 13.2
39121620
Drawings
10/30/2014 Page 3 / 4
https://www.phoenixcontact.com/us/products/2839541
Surge protection device - CF-UB-280DC-SB-SET - 2839541
Diagram
Circuit diagram
1,4 (0,17)
1,6
1,4
1,2
dB
1,0
1,3 (0,13)
1 0,8
1,2 (0,09)
aE
VSWR (r)
2
0,6
1,1 (0,05)
0,4
0,2
1M
1G
1,0 (0,0)
3G
2G
Frequency
1 Typical attenuation curve for CN-UB-280DC...
2 Typical VSWR at CN-UB-280DC...
Phoenix Contact 2014 © - all rights reserved