2855114

2855114

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    INPUTMODULE16DIGITAL24V

  • 数据手册
  • 价格&库存
2855114 数据手册
IB IL 24 DI 16 ... 1 2 1 2 D 1 2 Inline Terminal With 16 Digital Inputs 1 2 3 4 3 4 3 4 3 4 DI16 4x Data Sheet 5553_en_04 m AUTOMATIONWORX © PHOENIX CONTACT - 09/2007 Description on l in ec om po ne – – Connections for 16 digital sensors Connection of sensors in 2 and 3-wire technology Maximum permissible load current per sensor: 250 mA Maximum permissible load current from the terminal: 4.0 A Diagnostic and status indicators IB IL 24 DI 16 and IB IL 24 DI 16-PAC: Approved for use in potentially explosive areas (observe the notes on page 6) s. – – – – nt The terminal is designed for use within an Inline station. It is used to acquire digital signals. co Features This data sheet is only valid in association with the IL SYS INST UM E user manual or the Inline system manual for your bus system. Please note that the numbering of the terminal points differs for the various connector versions (see Figure 2 on page 5). Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page: IB IL 24 DI 16 ... Ordering Data Products Description Order No. Pcs./Pck. IB IL 24 DI 16-PAC 2861250 1 Terminal with 16 digital inputs; complete with accessories (connectors not consecutively numbered and labeling fields); transmission speed of 500 kbps IB IL 24 DI 16-PAC/SN 2862958 1 Terminal with 16 digital inputs; without accessories; transmission speed of 500 kbps IB IL 24 DI 16 2726230 1 Terminal with 16 digital inputs; complete with accessories (connectors not consecutively numbered and labeling fields); transmission speed of 2 Mbps IB IL 24 DI 16-2MBD-PAC 2861595 1 Terminal with 16 digital inputs; complete with accessories (connectors not consecutively numbered and labeling fields); transmission speed of 2 Mbps IB IL 24 DI 16-2MBD-PAC/SN Terminal with 16 digital inputs; without accessories; transmission speed of 2 Mbps IB IL 24 DI 16-2MBD m Type Terminal with 16 digital inputs; complete with accessories (connectors consecutively numbered and labeling fields); transmission speed of 500 kbps 1 co 2878120 1 s. 2855114 ne nt Four of the listed connectors or one connector set are needed for the complete fitting of the IB IL 24 DI 16 and IB IL 24 DI 16-2MBD. Accessories Description po Type Order No. Pcs./Pck. Connector with twelve spring-cage connections (green, without color print) IB IL SCN-12 2726340 10 Connector with twelve spring-cage connections (green, with color print) IB IL SCN-12-ICP 2727611 10 IB IL DI/DO 16-PLSET 2860976 1 IB IL DI 16-PLSET/ICP 2860989 1 Documentation Description om Connector set with 48 spring-cage connections (green, without color print) Connector set numbered consecutively with 48 spring-cage connections (green, with color print) Order No. Pcs./Pck. IL SYS INST UM E 2698737 1 "Configuring and Installing the INTERBUS Inline Product Range" user manual IB IL SYS PRO UM E 2743048 1 "INTERBUS Addressing" data sheet DB GB IBS SYS ADDRESS 9000990 1 "Inline Terminals for Use in Zone 2 Potentially Explosive Areas" application note AH EN IL EX ZONE 2 7217 1 "Addressing of 16-Channel Inline Terminals" application note AH IB IL 24 DI/DO 16 ADDRESS 9014124 1 on l in ec Type "Automation Terminals of the Inline Product Range" user manual 5553_en_04 PHOENIX CONTACT 2 IB IL 24 DI 16 ... Technical Data General Data Housing dimensions (width x height x depth) 48.8 mm x 120 mm x 71.5 mm Weight 122 g (without connectors), 210 g (with connectors) Operating mode Process data mode with 1 word Connection method for sensors 2 and 3-wire technology Permissible temperature (operation) -25°C to +55°C Permissible temperature (storage/transport) -25°C to +85°C Permissible humidity (operation/storage/transport) 10% to 95% according to DIN EN 61131-2 Permissible air pressure (operation/storage/transport) 70 kPa to 106 kPa (up to 3000 m above sea level) IP20 according to IEC 60529 Protection class Class 3 according to EN 61131-2, IEC 61131-2 m Degree of protection Connection data for connectors Spring-cage terminals Conductor cross-section 0.2 mm2 to 1.5 mm2 (solid or stranded), 24 - 16 AWG Interface Through data routing s. Local bus co Connection method nt Transmission Speed IB IL 24 DI 16-PAC 500 kbps 500 kbps ne IB IL 24 DI 16-PAC/SN IB IL 24 DI 16 500 kbps IB IL 24 DI 16-2MBD-PAC 2 Mbps 2 Mbps po IB IL 24 DI 16-2MBD-PAC/SN IB IL 24 DI 16-2MBD 2 Mbps om Supply of the Module Electronics and I/O Through Bus Terminal/Power Terminal Connection method Communications power in ec Power Consumption Current consumption from the local bus Through potential routing 500 kbps 2 Mbps 7.5 V 7.5 V 60 mA, maximum 80 mA, maximum Power consumption from the local bus 0.45 W, maximum 0.6 W, maximum Segment supply voltage US 24 V DC (nominal value) 24 V DC (nominal value) 4 A, maximum 4 A, maximum on l Nominal current consumption at US Digital Inputs Number Input design 16 According to EN 61131-2 Type 1 Definition of switching thresholds Maximum low-level voltage ULmax < 5 V Minimum high-level voltage UHmin > 15 V Common potentials Segment supply, ground Nominal input voltage UIN 24 V DC Permissible range -30 V < UIN < +30 V DC Nominal input current for UIN 3 mA, minimum Delay time None Permissible cable length to the sensor 30 m (to ensure conformance with EMC directive 89/336/EEC) Use of AC sensors AC sensors in the voltage range < UIN are limited in application (according to the input design) 5553_en_04 PHOENIX CONTACT 3 IB IL 24 DI 16 ... Characteristic Curve: Current Depending on the Input Voltage and the Ambient Temperature TA Supply Voltage Input Current Input Current for t >= 20 s For TA = 25°C For TA = 55°C 18 V 3.0 mA 2.9 mA 2.5 mA 24 V 3.9 mA 3.8 mA 3.5 mA 30 V 4.5 mA 4.2 mA 3.0 mA The current is reduced depending on the ambient temperature TA and the number of inputs that are switched on (internal module temperature). Power Dissipation Formula to Calculate the Power Dissipation of the Electronics 500 kbps 2 Mbps 16 m 16 PEL = 0.6 W + S [ UINn x 0.003 A ] PEL = 0.525 W + S [ UINn x 0.003 A ] n=1 Where PEL n UINn co n=1 Total power dissipation in the terminal Index of the number of set inputs n = 1 to 16 Input voltage of input n s. Power Dissipation of the Housing PHOU 2.8 W, maximum (within the permissible operating temperature) nt Limitation of Simultaneity, Derating No limitation of simultaneity, no derating ne Derating Error Messages to the Higher-Level Control or Computer System po None Safety Equipment Overload in segment circuit No om Surge voltage Polarity reversal Protective elements in the power terminal Protective elements in the power terminal in ec Electrical Isolation/Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I/O area it is necessary to supply the station bus coupler and the digital input terminal described here via the bus coupler or a power terminal from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted (see also user manual). Common Potentials on l The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. Separate Potentials in the System Consisting of Bus Terminal/Power Terminal and I/O Terminal Test Distance Test Voltage 5 V supply incoming remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 5 V supply outgoing remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min. 7.5 V supply (bus logic)/24 V supply (I/O) 500 V AC, 50 Hz, 1 min. 24 V supply (I/O)/functional earth ground 500 V AC, 50 Hz, 1 min. Approvals For the latest approvals, please visit www.download.phoenixcontact.com or eshop.phoenixcontact.com. 5553_en_04 PHOENIX CONTACT 4 IB IL 24 DI 16 ... Local Diagnostic and Status Indicators and Terminal Point Assignment Local Diagnostic and Status Indicators Terminal Point Assignment for Each Connector A D 1 1 2 1 3 2 4 3 2 1 .1 3 4 B 1 x 2 3 4 4 x 1 4 2 x x 1 2 2 .2 1 2 .1 1 .1 1 2 1 2 1 2 1 2 1 .1 2 .1 3 .1 4 .1 5 .1 6 .1 7 .1 8 .1 1 .2 2 .2 3 .2 4 .2 5 .2 6 .2 7 .2 8 .2 1 .3 2 .3 3 .3 4 .3 5 .3 6 .3 7 .3 8 .3 1 1 1 1 1 x 1 2 8 .2 3 8 .3 4 8 .4 5 8 .5 6 8 .6 1 1 8 .1 D I1 6 2 1 .3 3 3 1 .4 4 4 1 .2 2 .3 1 .3 2 .4 1 .4 2 .5 1 .5 2 2 2 3 3 3 1 .4 ne A om po Des. Color Meaning D Green Diagnostics For Each Connector 1, 2, 3, 4 Yellow Status indicators of the inputs Light blue – – B – on l in ec 2 Mbps: White stripe in the vicinity of the D LED – co 2 .6 1 .6 5 1 .6 4 .5 3 .6 4 .6 5 5 2 .6 6 3 .5 6 6 5 .4 6 .4 4 4 5 .5 6 .5 5 .6 6 .6 5 5 6 6 7 .4 8 .4 4 4 7 .5 8 .5 7 .6 8 .6 5 5 6 6 6 9 9 0 A 0 0 3 Terminal point numbering: individual connectors (A) and connector sets (B) Using the IB IL 24 DI 16-PAC/SN and IB IL 24 DI 16-2MBD-PAC/SN with the connectors provided Using individual connectors (IB IL SCN-12 or IB IL SCN-12-ICP) Using the IB IL 24 DI 16-PAC and IB IL 24 DI 16-2MBD-PAC with the original connector set Using the IB IL 24 DI 16-PLSET/ICP or IB IL DI/DO 16-PLSET connector sets Terminal Point x.1 x.2 x.3 x.4 x.5 x.6 5553_en_04 6 Figure 2 Local diagnostic and status indicators Function Identification 6 4 .4 3 3 nt 5 5 5 3 D 0 0 3 Figure 1 5 3 .4 2 .5 2 2 3 3 4 4 s. 1 .6 5 2 .4 4 1 .5 1 .5 2 2 m 1 .2 Assignment Signal input (IN) Segment voltage US for 2 and 3-wire termination Ground contact (GND) for 3-wire termination Signal input (IN) Segment voltage US for 2 and 3-wire termination Ground contact (GND) for 3-wire termination PHOENIX CONTACT 5 IB IL 24 DI 16 ... Notes on Using the Terminal in Potentially Explosive Areas for the IB IL 24 DI 16 and IB IL 24 DI 16-PAC Terminals Approval According to EC Directive 94/9 (ATEX) II 3G Ex nAC IIC T4 X UL xx LISTED 31ZN Proc. Ctrl. Eqpt. For Haz. Locs. Cl. I, Zn. 2, AEx nC IIC T5 Cl. I, Zn. 2, Ex nC IIC T5 Cl. I, Div. 2, Grp. A,B,C,D T5 5561C001 Typical labeling of terminals for use in potentially explosive areas on l Figure 3 GL in ec INTERBUS m co ne 5. When working on the Inline terminal, always disconnect the supply voltage. The Inline terminal must only be installed, started up, and maintained by qualified specialist personnel. Install the Inline terminals in a control cabinet or metal housing. The minimum requirement for both items is IP54 protection according to EN 60529. The Inline terminal must not be subject to mechanical strain and thermal loads, which exceed the limits specified in the product documentation. The Inline terminal must not be repaired by the user. Repairs may only be carried out by the manufacturer. The Inline terminal is to be replaced by an approved terminal of the same type. Only category 3G equipment may be connected to Inline terminals in zone 2. Observe all applicable standards and national safety and accident prevention regulations for installing and operating equipment. s. 4. po IBx IL xx xx x Order-No.: xxxxxxx Module-ID: xx HW/FW XX/- om II 3G Ex nAC IIC T4 X Potential routing 4 A maximum for use in Ex areas 1. 3. Before using an Inline terminal in a zone 2 potentially explosive area, first check that the terminal has been approved for installation in this area. Check the labeling on the Inline terminal and the packaging (see Figure 3). Before startup, ensure that the following points and instructions are observed. 2. WARNING: Explosion hazard Only Inline terminals that are approved for use in potentially explosive areas may be snapped next to this Inline terminal. For a list of terminals approved for zone 2 potentially explosive areas, please refer to the AH EN IL EX ZONE 2 application note. WARNING: Explosion hazard nt This Inline terminal conforms to the requirements of protection type "n" and can be installed in a zone 2 potentially explosive area. This Inline terminal is a category 3G item of electrical equipment. 6. 7. Restrictions WARNING: Explosion hazard When using terminals in potentially explosive areas, observe the technical data and limit values specified in the corresponding documentation (user manual, data sheet, package slip). WARNING: Explosion hazard; Restrictions regarding the Inline system The maximum permissible current through the potential jumpers UM and US (total current) is limited to 4 A when using this Inline terminal in potentially explosive areas. 5553_en_04 PHOENIX CONTACT 6 IB IL 24 DI 16 ... Internal Basic Circuit Diagram L o c a l b u s O P C U L 8 2 2 2 2 2 2 8 2 8 8 2 2 2 2 2 2 2 2 ) S M ) Figure 4 Internal wiring of the terminal points Key: Protocol chip (bus logic including voltage conditioning) LED in ec OPC 5 5 5 3 C 0 0 4 om po ne + 2 4 V (U nt + 2 4 V (U s. co m 2 on l Optocoupler Digital input Electrically isolated area Other symbols used are explained in the IL SYS INST UM E user manual or in the Inline system manual for your bus system. 5553_en_04 PHOENIX CONTACT 7 IB IL 24 DI 16 ... Connection Notes and Connection Example Programming Data/Configuration Data Local Bus (INTERBUS) When connecting the sensors observe the assignment of the terminal points to the process data (see page 9). 1 BEhex (190dec) Length code 01hex Process data channel 16 bits Input address area 1 word Output address area 0 words Parameter channel (PCP) 0 words Register length (bus) 1 word 4 3 2 ID code D 2 1 1 2 3 4 1 2 3 2 3 4 For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). s. 1 co Other Bus Systems 3 4 4 A B 33 33 3 44 B 4 5 55 55 55 5 6 66 66 66 6 +24 V 44 IN15 IN16 44 in ec 4 IN14 33 A IN16 3 om 2 IN11 IN12 22 IN7 IN8 22 IN3 IN4 22 po 1 +24 V 11 2 ne 1 IN13 IN14 11 2 IN9 IN10 IN5 IN6 1 on l +24 V IN1 IN3 +24 V Figure 5 11 2 2 A A 1 IN1 IN2 1 2 nt DI16 1 m Please note that the terminal must be provided with supply voltage US, as it is used internally as the auxiliary supply. 5553D005 Typical connection of sensors 3-wire termination 2-wire termination The numbers above the module illustration indicate the connector slots. 5553_en_04 PHOENIX CONTACT 8 IB IL 24 DI 16 ... Process Data For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. For the assignment of the illustrated (byte.bit) view to control systems of other bus systems, please refer to the AH IB IL 24 DI/DO ADDRESS document. Assignment of the Terminal Points to the IN Process Data Word 0 Bit 13 7 6 5 12 11 10 9 2 1 Byte 0 Byte Bit 3 4 8 7 0 7 6 5 6 5 3 4 3 2 1 0 2 1 0 Byte 1 4 3 2 1 nt Slot 4 Terminal point (signal) 8.4 7.4 8.1 7.1 6.4 5.4 6.1 5.1 4.4 3.4 4.1 3.1 2.4 1.4 2.1 1.1 Terminal point (+24 V) 8.5 7.5 8.2 7.2 6.5 5.5 6.2 5.2 4.5 3.5 4.2 3.2 2.5 1.5 2.2 1.2 Terminal point (GND) 8.6 7.6 8.3 7.3 6.6 5.6 6.3 5.3 4.6 3.6 4.3 3.3 2.6 1.6 2.3 1.3 Status indication Slot 4 4 3 2 1 4 3 3 2 2 1 4 3 1 2 1 4 3 2 1 om LED po Module 14 s. (Byte.bit) view 15 co Word ne (Word.bit) view m The following table applies to the IB IL 24 DI 16-PAC and IB IL 24 DI 16-2MBD-PAC with the original connector set and when using the IB IL DI/DO 16-PLSET or IB IL DI 16-PLSET/ICP connector sets (see also Figure 2 on page 5, detail B). (Word.bit) view Word Bit (Byte.bit) view Byte Module on l Bit in ec The following table applies to the IB IL 24 DI 16-PAC/SN and IB IL 24 DI 16-2MBD-PAC/SN with the original connector set and when using the B IL SCN-12 or IB IL SCN-12-ICP connectors (see also Figure 2 on page 5, detail A). Word 0 15 14 13 12 11 10 9 8 7 6 5 Byte 0 7 6 Slot 5 4 3 4 3 2 1 0 2 1 0 Byte 1 2 4 1 0 7 6 3 5 4 3 2 1 Terminal point (signal) 2.4 1.4 2.1 1.1 2.4 1.4 2.1 1.1 2.4 1.4 2.1 1.1 2.4 1.4 2.1 1.1 Terminal point (+24 V) 2.5 1.5 2.2 1.2 2.5 1.5 2.2 1.2 2.5 1.5 2.2 1.2 2.5 1.5 2.2 1.2 Terminal point (GND) 2.6 1.6 2.3 1.3 2.6 1.6 2.3 1.3 2.6 1.6 2.3 1.3 2.6 1.6 2.3 1.3 Status indication Slot LED 4 4 3 3 2 1 4 3 2 2 1 4 3 1 2 1 4 3 2 1 © PHOENIX CONTACT 09/2007 5553_en_04 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany Phone: +49 - 52 35 - 30 0 • Fax: +49 - 52 35 - 34 18 08 www.phoenixcontact.com 9
2855114 价格&库存

很抱歉,暂时无法提供与“2855114”相匹配的价格&库存,您可以联系我们找货

免费人工找货