2855127

2855127

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    COMMUNICATIONSMODULE24V

  • 数据手册
  • 价格&库存
2855127 数据手册
IBS IL 24 BK RB-T-2MBD INTERBUS Inline Terminal for Connecting a Remote Bus Branch Data Sheet 6766A 6 0 3 6 B 0 0 1 01/2003 This data sheet is only valid in association with the "Configuring and Installing the INTERBUS Inline Product Range" User Manual IB IL SYS PRO UM E. Function This terminal can be used to create a remote bus branch from an Inline station. It can also be used to integrate remote devices (e.g., display fields, keypads, motor starters with IP 65 protection or sensor/actuator boxes) into INTERBUS via an Inline station. Features 5 0 3 6 B 0 0 3 – Connections for a remote bus branch using copper technology – Supply of the remote bus branch terminal via the bus terminal or a pre-connected power terminal (not a bus device) Please note the "Configuration Notes" on page 4 to avoid configuration errors. 6766A Figure 1 The IBS IL 24 RB-T-2MBD terminal with connector Please note that the connector is not supplied as standard with the terminal. Refer to the Ordering Data on page 10 to order the appropriate connector for your application. 1 IBS IL 24 RB-T-2MBD Local Diagnostic Indicators D R C R D L D R B -T Des. D Color Meaning Green Bus diagnostics RC Green Remote bus cable check RD Yellow Remote bus branch switched off LD Yellow Local bus switched off LD Red Isolated disconnection of local bus after error Function Identification Gray 1 2 1 .1 1 1 2 .1 1 .2 2 2 2 .2 1 .3 3 3 2 .3 1 .4 4 4 2 .4 Terminal Assignment Terminal Assignment Point 6 0 3 6 B 0 0 2 Figure 2 IBS IL 24 RB-T-2MBD with appropriate connector 1.1 2.1 1.2 2.2 1.3 2.3 1.4, 2.4 2 Remark/ Wire Color in the INTERBUS Standard Cable Receive Green DO DO Receive Yellow Send Pink DI DI Send Gray GND Reference Brown potential Not used Shield Shield potential is directly connected to functional earth ground (FE) of the voltage jumper. 6766A IBS IL 24 RB-T-2MBD Internal Circuit Diagram Key: IN T E R B U S U U U O P C OPC L + A N A L - INTERBUS protocol chip (bus logic including voltage conditioning) LED Optocoupler 2 4 V 5 V 1 5 V 5 V R S -4 2 2 In te rfa c e / R S -4 2 2 In te rfa c e / R S -4 2 2 In te rfa c e Interface component Electrically isolated area / Other symbols are explained in the IB IL SYS PRO UM E User Manual. + 2 4 V (U S ) + 2 4 V (U M ) Power supply unit with electrical isolation Ground; electrically isolated from ground of the voltage jumper (GND) 1 6 0 3 6 B 0 0 5 Figure 3 6766A Internal wiring of the terminal points 3 IBS IL 24 RB-T-2MBD Connection Example IB S IL 2 4 B K -T /U B A R D R C L D Configuration Notes IB S IL 2 4 R B -T D R C U S U L The terminal for connecting a remote bus branch must be positioned directly after a bus terminal, a control terminal, or a terminal with remote bus branch. Directly means that there must be no bus device between the bus terminal/control terminal and the terminal with remote bus branch. R D U M Only one remote bus branch terminal may be used within an Inline station with an IBS IL 24 BK-T. L D B K -T /U 1 R B -T 2 1 2 1 2 1 2 1 2 1 1 1 1 1 1 1 1 1 1 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 Up to 15 terminals with remote bus branch may be used after other bus terminals or after the control terminal if no restrictions are made in the according terminal-specific data sheets. Programming Data IN T E R B U S IN IN T E R B U S O U T 1 Figure 4 IN T E R B U S O U T 2 04hex (04dec) Length code 00hex Process data channel 0 bytes Input address area 0 bytes Output address area 0 bytes Parameter channel (PCP) 0 bytes Register length (bus) 0 bytes 6 0 3 6 B 0 0 4 Example of connecting the INTERBUS cables to the bus terminal and to the remote bus branch terminal INTERBUS IN Incoming Remote Bus INTERBUS OUT 1 Outgoing Remote Bus INTERBUS OUT 2 Remote bus branch 4 ID code 6766A IBS IL 24 RB-T-2MBD Technical Data General Data Housing dimensions (width x height x depth) 12.2 mm x 120 mm x 71.5 mm (0.480 in. x 4.724 in. x 2.815 in.) Weight 46 g (without connectors) Permissible temperature (operation) -25°C to +55°C (-13°F to +131°F) Permissible temperature (storage/transport) -25°C to +85°C (-13°F to +185°F) Permissible humidity (operation) 75% on average, 85% occasionally In the range from -25°C to +55°C (-13°F to +131°F) appropriate measures against increased humidity (> 85%) must be taken. Permissible humidity (storage/transport) 75% on average, 85% occasionally For a short period, slight condensation may appear on the housing if, for example, the terminal is brought into a closed room from a vehicle. Permissible air pressure (operation) 80 kPa to 106 kPa (up to 2000 m [6562 ft.] above sea level) Permissible air pressure (storage/transport) 70 kPa to 106 kPa (up to 3000 m [9843 ft.] above sea level) Degree of protection IP 20 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Interfaces (INTERBUS) Remote bus Incoming remote bus Through data routing Outgoing remote bus Through data routing Remote bus branch Copper cable (RS-422), connected via Inline shield connector; electrically isolated supply, shielding directly connected to functional earth ground Recommended cable lengths See INTERBUS system data 6766A 5 IBS IL 24 RB-T-2MBD Interfaces (INTERBUS) (Continued) Local Bus Connection Through data routing Level 5 V CMOS signal level Number of Inline terminals that can be connected Limitation through software 63, maximum Limitation through power supply unit Maximum logic current consumption of the connected local bus terminals: Imax ≤ 2 A DC Observe the current consumption of the terminals Observe the logic current consumption of each device when configuring an Inline station. This information is given in every terminal-specific data sheet. The current consumption can differ depending on the individual terminal. The permissible number of devices that can be connected depends on the specific station structure. The remote bus branch devices do not count as Inline station devices. Power Consumption Communications voltage UL – Current consumption from UL – Power consumption from UL – Analog supply voltage UANA 24 V DC (nominal value) Nominal current consumption at UANA 0.029 A (nominal value) Power consumption from UANA 0.696 W, maximum Supply of the Module Electronics Through the Bus Terminal (UANA) Connection method 6 Through potential routing 6766A IBS IL 24 RB-T-2MBD Power Dissipation Formula to Calculate the Power Dissipation of the Electronics PEL = UANA x ITOT Where PEL UANA ITOT Total power dissipation of the terminal Analog voltage Total current consumption in the remote bus branch terminal at UANA Example: PEL = 24 V x 29 mA PEL = 696 mW Power Dissipation of the Housing PHOU = 0.7 W in the total permissible ambient temperature range Where PHOU Permissible power dissipation of the housing Derating No derating Error Messages to the Higher-Level Control or Computer System None Safety Devices None 6766A 7 IBS IL 24 RB-T-2MBD Electrical Isolation/Isolation of the Voltage Areas Common Potentials The 7.5 V communications power, 24 V analog supply, 24 V bus terminal supply and the 5 V communications power of the remote bus branch terminal share a common potential. Separate Potentials The communications power ground is jumpered with the ground of the 7.5 V communications power for the bus terminal power supply unit. The interface supply for the remote bus branch is electrically isolated from all other potentials. The I/O supply is always electrically isolated from the interface supplies. Electrical Isolation/Isolation of the Voltage Areas With a Combination of the IBS IL 24 BK-T Bus Terminal and the IBS IL 24 RB-T-2MBD Remote Bus Branch Terminal Test Distance Test Voltage 5 V supply of incoming remote bus electrically isolated from – 5 V supply of outgoing remote bus – 5 V supply of remote bus branch – 7.5 V communications power, 24 V analog supply, 24 V bus terminal supply, 5 V communications power of remote bus branch terminal – 24 V main supply, 24 V segment supply – Functional earth ground 500 V AC, 50 Hz, 1 min 5 V supply of outgoing remote bus electrically isolated from – 5 V supply of incoming remote bus – 5 V supply of remote bus branch – 7.5 V communications power, 24 V analog supply, 24 V bus terminal supply, 5 V communications power of remote bus branch terminal – 24 V main supply, 24 V segment supply – Functional earth ground 8 500 V AC, 50 Hz, 1 min 6766A IBS IL 24 RB-T-2MBD Electrical Isolation/Isolation of the Voltage Areas With a Combination of the IBS IL 24 BK-T Bus Terminal and the IBS IL 24 RB-T-2MBD Remote Bus Branch Terminal 7.5 V communications power, 24 V analog supply, 24 V bus terminal supply, 5 V communications power of remote bus branch terminal electrically isolated from – 5 V supply of incoming remote bus – 5 V supply of outgoing remote bus – 5 V supply of remote bus branch – 24 V main supply, 24 V segment supply – Functional earth ground 500 V AC, 50 Hz, 1 min 24 V main supply, 24 V segment supply electrically isolated from – 5 V supply of incoming remote bus – 5 V supply of outgoing remote bus – 5 V supply of remote bus branch – 7.5 V communications power, 24 V analog supply, 24 V bus terminal supply, 5 V communications power of remote bus branch terminal – Functional earth ground 500 V AC, 50 Hz, 1 min 5 V supply of remote bus electrically isolated from – 5 V supply of incoming remote bus – 5 V supply of outgoing remote bus – 7.5 V communications power, 24 V analog supply, 24 V bus terminal supply, 5 V communications power of remote bus branch terminal – 24 V main supply, 24 V segment supply – Functional earth ground 6766A 500 V AC, 50 Hz, 1 min 9 IBS IL 24 RB-T-2MBD Description Order Designation Order No. INTERBUS Inline terminal for connecting a remote bus branch IBS IL 24 RB-T-2MBD 28 55 12 7 Shield connector; pack of 5 IB IL SCN-6 SHIELD 27 26 35 3 "Configuring and Installing the INTERBUS Inline Product Range" User Manual IB IL SYS PRO UM E 27 43 04 8 © Phoenix Contact 01/2003 Technical modifications reserved TNR 90 12 64 1 Ordering Data Phoenix Contact GmbH & Co. KG Flachsmarktstr. 8 32825 Blomberg Germany + 49 - (0) 52 35 - 3-00 + 49 - (0) 52 35 - 3-4 12 00 www.phoenixcontact.com Worldwide Locations: www.phoenixcontact.com/salesnetwork 10 6766A
2855127 价格&库存

很抱歉,暂时无法提供与“2855127”相匹配的价格&库存,您可以联系我们找货

免费人工找货