2858014

2858014

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    模块

  • 描述:

    SURGE PROTECTION PLUG 48VDC

  • 数据手册
  • 价格&库存
2858014 数据手册
https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protection plug for the base element, common mode voltage coarse and fine protection for four lines with a common reference potential. Design: 48 V DC Your advantages  Plugs can be checked with CHECKMASTER  Maximum ease of maintenance thanks to the two-piece design  Base element remains an integral part of the installation  Consistent plug-in signal circuit protection  Protection for four conductors with common reference potential  Impedance-neutral disconnection of plug for test and maintenance purposes Key Commercial Data Packing unit 1 pc GTIN GTIN 4017918828325 Weight per Piece (excluding packing) 25.760 g Custom tariff number 85363010 Country of origin Germany Technical data Dimensions Height 45 mm Width 17.7 mm Depth 52 mm 08/05/2019   Page 1 / 7 https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Technical data Dimensions Horizontal pitch 1 Div. Complete module height 90 mm Complete module width 17.7 mm Complete module depth 65.5 mm Ambient conditions Ambient temperature (operation) -40 °C ... 85 °C Degree of protection IP20 General Housing material PA 6.6 Flammability rating according to UL 94 V-0 Color jet black RAL 9005 Mounting type on base element Type Male Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.00 Protective circuit IEC test classification C1 C2 C3 D1 VDE requirement class C1 C2 C3 D1 Nominal voltage UN 48 V DC Maximum continuous voltage UC 53 V DC 37 V AC Rated current 300 mA (45 °C) Operating effective current IC at UC ≤ 5 µA Residual current IPE ≤ 1 µA (with PT 4X1+F-BE) ≤ 20 µA (Directly grounded) Nominal discharge current In (8/20) µs (line-earth) 10 kA Pulse discharge current Iimp (10/350) µs 2.5 kA (per path) Total discharge current Itotal (8/20) µs 20 kA Max. discharge current Imax (8/20) µs maximum (line-earth) 10 kA 08/05/2019   Page 2 / 7 https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Technical data Protective circuit Nominal pulse current Ian (10/1000) µs (line-earth) 17 A Output voltage limitation at 1 kV/µs (line-earth) spike ≤ 75 V Output voltage limitation at 1 kV/µs (line-earth) static ≤ 70 V Residual voltage at In (line-earth) ≤ 70 V Voltage protection level Up (line-earth) ≤ 130 V (C2 - 10 kV / 5 kA) Response time tA (line-earth) ≤ 1 ns Input attenuation aE, asym. 0.5 dB (≤ 1.7 MHz) Cut-off frequency fg (3 dB), asym. (PE) in 50 Ohm system typ. 9 MHz Capacity (line-earth) 0.9 nF Resistance in series 4.7 Ω Max. required back-up fuse 315 mA (T) Impulse durability (line-earth) C2 - 10 kV / 5 kA D1 - 2.5 kA Connection data Connection method Screw connection (in connection with the base element) Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section solid 0.2 mm² ... 4 mm² Conductor cross section AWG 24 ... 12 Standards and Regulations Standards/specifications IEC 61643-21 2000 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130800 eCl@ss 6.0 27130800 08/05/2019   Page 3 / 7 https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Classifications eCl@ss eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 ETIM 6.0 EC000943 ETIM 7.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals EAC Ex Approvals Approval details EAC      RU CDE.A*30.B01561 Accessories Accessories Device marking 08/05/2019   Page 4 / 7 https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Accessories Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128 Zack marker strip, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into tall marker groove, for terminal block width: 18 mm, lettering field size: 18 x 5 mm     Labeled terminal marker Zack Marker strip, flat - ZBF 5,LGS:FORTL.ZAHLEN - 0808671 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 491 ... 500, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm     Zack Marker strip, flat - ZBF 5,LGS:GERADE ZAHLEN - 0810821 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: consecutive numbers 2 ... 20, 22 ... 40, etc. up to 82 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm     Zack Marker strip, flat - ZBF 5,LGS:UNGERADE ZAHLEN - 0810863 Zack Marker strip, flat, Strip, white, labeled, printed horizontally: Odd numbers 1 - 19, 21 - 39, etc. up to 81 - 99, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm     Zack Marker strip, flat - ZBF 5,QR:FORTL.ZAHLEN - 0808697 Zack Marker strip, flat, Strip, white, labeled, Printed vertically: consecutive numbers 1 ... 10, 11 ... 20, etc. up to 91 ... 100, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm     08/05/2019   Page 5 / 7 https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Accessories Marker pen Marker pen - X-PEN 0,35 - 0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm     Terminal marking Zack Marker strip, flat - ZBF 5:UNBEDRUCKT - 0808642 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: PLOTMARK, CMS-P1-PLOTTER, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.1 x 5.2 mm     Zack Marker strip, flat - ZBF 5/WH-100:UNBEDRUCKT - 0808668 Zack Marker strip, flat, Strip, white, unlabeled, can be labeled with: CMS-P1-PLOTTER, PLOTMARK, mounting type: snap into flat marker groove, for terminal block width: 5 mm, lettering field size: 5.15 x 5.15 mm     Necessary add-on products Surge protection base element - PT 4X1-BE - 2839363 Base element for protective plug PT with protective circuit for 4 conductors of signal circuits grounded on one side, with bridge between the connections 3-4 (GND) and 9-10, for mounting on NS 35/7.5 and NS 35/15, housing width: 17.5 mm     08/05/2019   Page 6 / 7 https://www.phoenixcontact.com/us/products/2858014 Surge protection plug - PT 4X1-48DC-ST - 2858014 Accessories Surge protection base element - PT 4X1+F-BE - 2839376 Base element for protective plug PT with protective circuit for 4 signal wires, with gas-filled surge arrester between the connections 3-4 (GND) and 9-10, for mounting on NS 35/7.5 and NS 35/15, housing width: 17.5 mm     Additional products Shield connection - SSA 3-6 - 2839295 Shield fast connection for 3 ... 6 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black     Shield connection - SSA 5-10 - 2839512 Shield fast connection for 5 ... 10 mm cable diameter. Potential connecting cable: 200 mm, 1 mm², color: black     Phoenix Contact 2019 © - all rights reserved http://www.phoenixcontact.com 08/05/2019   Page 7 / 7
2858014 价格&库存

很抱歉,暂时无法提供与“2858014”相匹配的价格&库存,您可以联系我们找货

免费人工找货