0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2858030

2858030

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    Modular

  • 描述:

    TVS DIODE 5VWM MODULE

  • 数据手册
  • 价格&库存
2858030 数据手册
https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Surge protection plug for the base element, normal mode voltage coarse and fine protection for two floating signal wires in IT, common mode voltage coarse protection to ground. Product Features ■ ■ ■ ■ ■ ■ Plugs can be checked with CHECKMASTER Maximum ease of maintenance thanks to the two-piece design Base element remains an integral part of the installation Protection for fieldbus systems, PROFIBUS, and signal circuits with 3 to 5-wire technology Consistent plug-in signal circuit protection Impedance-neutral disconnection of plug for test and maintenance purposes Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 20.68 g Custom tariff number 85363090 Country of origin Germany Technical data Dimensions Height 45 mm Width 17.7 mm Depth 52 mm Horizontal pitch 1 Div. Complete module height 90 mm Complete module width 17.7 mm 04/19/2016   Page 1 / 7 https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Technical data Dimensions Complete module depth 65.5 mm Ambient conditions Ambient temperature (operation) -40 °C ... 85 °C Degree of protection IP20 General Housing material PA Flammability rating according to UL 94 V-0 Color black Standards for cearances and creepage distances DIN EN 61664-1 IEC 60664-1 Mounting type On base element Type DIN rail module, two-section, divisible Number of positions 2 Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/ShieldEarth Ground Arrester can be tested with CHECKMASTER from software version: From SW rev. 1.10 Protective circuit IEC test classification C1 C2 C3 D1 VDE requirement class C1 C2 C3 D1 Nominal voltage UN 5 V DC Maximum continuous voltage UC 5.2 V DC 3.6 V AC Maximum continuous voltage UC (wire-wire) 5.2 V DC 3.6 V AC Maximum continuous voltage UC (wire-ground) 5.2 V DC (PT 1x2-BE) 3.6 V AC (PT 1x2-BE) Nominal current IN 450 mA (45°C) Operating effective current IC at UC ≤ 300 µA Residual current IPE ≤ 300 µA (PT 1x2-BE) ≤ 1 µA (PT 1x2+F-BE) 04/19/2016   Page 2 / 7 https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Technical data Protective circuit Nominal discharge current In (8/20) µs (Core-Core) 10 kA Nominal discharge current In (8/20) µs (Core-Earth) 10 kA Total surge current (8/20) µs 20 kA Max. discharge current Imax (8/20) µs maximum (Core-Core) 10 kA Max. discharge current Imax (8/20) µs maximum (Core-Earth) 10 kA Nominal pulse current Ian (10/1000) µs (Core-Core) 90 A Impulse discharge current (10/350)˽µs, peak value limp 2.5 kA Output voltage limitation at 1 kV/µs (Core-Core) spike ≤ 55 V Output voltage limitation at 1 kV/µs (Core-Earth) spike ≤ 55 V (PT 1x2-BE) ≤ 700 V (PT 1x2+F-BE) Output voltage limitation at 1 kV/µs (Core-Core) static ≤ 15 V Output voltage limitation at 1 kV/µs (Core-Earth) static ≤ 15 V ≤ 30 V (PT 1x2+F-BE) Residual voltage at In (conductor-conductor) ≤ 15 V Residual voltage at In (conductor-ground) ≤ 30 V (PT 1x2-BE) Residual voltage at In (conductor-GND) ≤ 15 V (PT 1x2-BE) Residual voltage with Ian (10/1000)µs (conductor-conductor) ≤ 15 V Residual voltage with Ian (10/1000)µs (conductor-GND) ≤ 15 V Voltage protection level Up (core-core) ≤ 70 V (C1 - 1 kV/500 A) ≤ 45 V (C3 - 25 A) ≤ 100 V (C2 - 10 kV/5 kA) ≤ 70 V (6 kV/3 kA) Voltage protection level Up (core-ground) ≤ 80 V (C1 - 1 kV/500 A) ≤ 110 V (C2 - 10 kV/5 kA) ≤ 100 V (6 kV/3 kA) ≤ 45 V (C3 - 25 A) Voltage protection level Up (core-GND) ≤ 45 V (C3 - 25 A) Response time tA (Core-Core) ≤ 500 ns Response time tA (Core-Earth) ≤ 500 ns ≤ 500 ns Input attenuation aE, sym. typ. 0.3 dB (≤ 5 MHz / 100 Ω) Cut-off frequency fg (3 dB), sym. in 100 Ohm system typ. 60 MHz Capacity (Core-Core) typ. 30 pF Resistance in series 2.2 Ω ±10 % (7-8/11-12) Surge protection fault message None Max. required back-up fuse 500 mA (e.g. T in acc. with IEC 127-2/III) Impulse durability (conductor-conductor) C2 - 10 kV/5 kA 04/19/2016   Page 3 / 7 https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Technical data Protective circuit C3 (90 A) Impulse durability (conductor-ground) C2 - 10 kV/5 kA C3 (90 A) D1 - 2,5 kA Connection data Connection method Screw connection (in connection with the base element) Connection type IN PLUGTRAB plug-in system Connection type OUT PLUGTRAB plug-in system Screw thread M3 Tightening torque 0.8 Nm Stripping length 8 mm Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section solid 0.2 mm² ... 4 mm² Conductor cross section AWG 24 ... 12 Connection, equipotential bonding Stripping length 8 mm Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 4 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Classifications eCl@ss eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130807 eCl@ss 7.0 27130807 eCl@ss 8.0 27130807 eCl@ss 9.0 27130807 04/19/2016   Page 4 / 7 https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Classifications ETIM ETIM 2.0 EC000943 ETIM 3.0 EC000943 ETIM 4.0 EC000943 ETIM 5.0 EC000943 UNSPSC UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals UL Listed / GL / EAC / EAC Ex Approvals Approvals submitted Approval details UL Listed  GL  EAC  EAC  04/19/2016   Page 5 / 7 https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Drawings Dimensional drawing Circuit diagram 90 44,8 7 8 11 12 OUT IN 10 9 * 4 51,5 65,5 3 The figure shows the complete module consisting of a base element and connector 04/19/2016   Page 6 / 7 https://www.phoenixcontact.com/us/products/2858030 Surge protection plug - PT 3-PB-ST - 2858030 Application drawing Connecting M-UFB IBS-MUX to the field multiplexer Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/19/2016   Page 7 / 7
2858030 价格&库存

很抱歉,暂时无法提供与“2858030”相匹配的价格&库存,您可以联系我们找货

免费人工找货