https://www.phoenixcontact.com/us/produkte/2859466
Type 2 surge protection device - VAL-CP-3C-175 - 2859466
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in
the user's documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Pluggable type 2 arrester (surge arrester) for 3-phase current supply networks with N and PE in a
common conductor (4-conductor system: L1, L2, L3, PEN), with remote indication contact. Overall
width: 36 mm.
Why buy this product
With or without floating remote indication contact
Plugs can be checked with CHECKMASTER
High continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations
Mechanical keying of all slots
Optical, mechanical status indication for the individual arresters
Type 2 consistent plug-in surge arresters
Disconnect device on each individual plug
Use of varistors that are free of leakage current
Modular arrester blocks with ultra-narrow design
Key commercial data
Packing unit
1
Minimum order quantity
1
Catalog page
Page 32 (TT-2011)
GTIN
Custom tariff number
85369010
Country of origin
GERMANY
Technical data
Standards
Housing material
PBT
Inflammability class according to UL 94
V0
Color
gray
Standards for air and creepage distances
DIN VDE 0110-1
Standards for air and creepage distances
IEC 60664-1
Standards for air and creepage distances
IEC 61643-1
Surge voltage category
III
04.10.2012 Page 1 / 6
https://www.phoenixcontact.com/us/produkte/2859466
Type 2 surge protection device - VAL-CP-3C-175 - 2859466
Technical data
Standards
Pollution degree
2
Degree of protection
IP20
Mounting type
DIN rail: 35 mm
Design
DIN rail module, two-section, divisible
Number of positions
3
Ambient temperature (operation)
-40 °C ... 80 °C
Message: Surge protection fault
Optical, remote indicator contact
Direction of action
3L-N/PE
Width
37.25 mm
Height
98.5 mm
Depth
70 mm
Protective circuit
IEC category
II
IEC category
T2
EN type
T2
Nominal voltage UN
120 V AC (3P/PEN)
Nominal voltage UN
208 V AC (Phase - Phase)
Arrester rated voltage UC
175 V AC
Arrester rated voltage UC (L-PEN)
175 V AC
UT (TOV-proof)
240 V AC (5 s)
Nominal frequency fN
50 Hz
Nominal frequency fN
60 Hz
Nominal load current IL
40 A (40 A ... 63 A)
Nominal load current IL
63 A (10 mm2)
Ground conductor current IPE
≤ 300 µA
Standby power consumption PC
≤ 17.5 mW
Max. discharge surge current Imax (8/20) µs maximum (L-PEN)
120 kA (all channels)
Nominal discharge surge current In (8/20) µs (L-PEN)
20 kA (per channel)
Nominal discharge surge current In (8/20) µs (L-PEN)
60 kA (all channels)
Protection level UP (L-PEN)
≤ 850 V (at In)
Residual voltage (L-PEN)
≤ 700 V (at 10 kA)
Residual voltage (L-PEN)
≤ 600 V (at 5 kA)
Residual voltage (L-PEN)
≤ 550 V (at 3 kA)
Residual voltage (L-PEN)
≤ 850 V
Response time (L-N)
≤ 25 ns
Max. required backup fuse with branch wiring
125 A (gL/gG)
Max. required backup fuse with V-type through wiring
40 A (gL/gG)
Short-circuit resistance IP with max. backup fuse (effective)
25 kA
Connection, protective circuit
Connection method
Screw connection
Connection type IN
Biconnect screw terminal block
Connection type OUT
Biconnect screw terminal block
04.10.2012 Page 2 / 6
https://www.phoenixcontact.com/us/produkte/2859466
Type 2 surge protection device - VAL-CP-3C-175 - 2859466
Technical data
Connection, protective circuit
Connection method
Biconnect terminal block
Screw thread
M5
Tightening torque
4.5 Nm
Stripping length
16 mm
Conductor cross section stranded min.
2.5 mm²
Conductor cross section stranded max.
16 mm²
Conductor cross section solid min.
2.5 mm²
Conductor cross section solid max.
25 mm²
Conductor cross section AWG/kcmil min.
12
Conductor cross section AWG/kcmil max
4
Remote indicator contact
Connection name
Remote fault indicator contact
Switching function
PDT contact
Connection method
Pluggable screw connection
Screw thread
M2
Tightening torque
0.25 Nm
Stripping length
7 mm
Conductor cross section stranded min.
0.14 mm²
Conductor cross section stranded max.
1.5 mm²
Conductor cross section solid min.
0.14 mm²
Conductor cross section solid max.
1.5 mm²
Conductor cross section AWG/kcmil min.
28
Conductor cross section AWG/kcmil max
16
Maximum operating voltage Umax. AC
250 V AC
Maximum operating voltage Umax DC
125 V DC
Max. operating current Imax
1 A AC (inductive)
Max. operating current Imax
1 A AC (ohmic)
Max. operating current Imax
30 mA DC (inductive)
Max. operating current Imax
200 mA DC (ohmic)
Min. permissible switching capacity
0.12 VA (12 V, 10 mA)
Standards
Standards/regulations
IEC 61643-1 1998
Standards/regulations
DIN EN 61643-11 2002
Standards/regulations
UL 1449
Standards/regulations
IEEE C62.1 / C62.34 / C62.45
Classifications
eclass
eCl@ss 4.0
27140201
eCl@ss 4.1
27130801
eCl@ss 5.0
27130801
04.10.2012 Page 3 / 6
https://www.phoenixcontact.com/us/produkte/2859466
Type 2 surge protection device - VAL-CP-3C-175 - 2859466
Classifications
eclass
eCl@ss 5.1
27130801
eCl@ss 6.0
27130805
eCl@ss 7.0
27130805
etim
ETIM 2.0
EC000941
ETIM 3.0
EC000941
ETIM 4.0
EC000941
unspsc
UNSPSC 6.01
30212010
UNSPSC 7.0901
39121610
UNSPSC 11
39121610
UNSPSC 12.01
39121610
UNSPSC 13.2
39121620
Approvals
Approvals
Approvals
UL Recognized / KEMA-KEUR / cUL Recognized / GOST / IECEE CB Scheme / cULus Recognized
Ex Approvals
Approvals submitted
Approval details
UL Recognized
KEMA-KEUR
cUL Recognized
04.10.2012 Page 4 / 6
https://www.phoenixcontact.com/us/produkte/2859466
Type 2 surge protection device - VAL-CP-3C-175 - 2859466
Approvals
GOST
IECEE CB Scheme
cULus Recognized
Accessories
Accessories
Bridges
Wiring bridge - MPB SET VAL-CP-3S - 2880684
Wiring bridge set, consisting of three flexible bridges 15 cm black, 1 bridge 27 cm blue.
Marking
Zack Marker strip, flat - ZBF 12:UNBEDRUCKT - 0809735
Zack Marker strip, flat, Strip, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into flat
marker groove, For terminal block width: 12 mm, Lettering field: 5.15 x 12.15 mm
Marker pen - X-PEN 0,35 - 0811228
Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line
thickness 0.35 mm
04.10.2012 Page 5 / 6
https://www.phoenixcontact.com/us/produkte/2859466
Type 2 surge protection device - VAL-CP-3C-175 - 2859466
Accessories
Flat zack marker sheet - ZBFM 5/WH:UNBEDRUCKT - 0803595
Flat zack marker sheet, Sheet, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into flat
marker groove, For terminal block width: 5.2 mm, Lettering field: 5 x 4.5 mm
Drawings
Dimensioned drawing
Circuit diagram
PEN
98
12
22,5
11
14
FM
64
51,5
71,5
45
L1
L2
L3
© Phoenix Contact 2012 - all rights reserved
http://www.phoenixcontact.com
04.10.2012 Page 6 / 6