0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2859505

2859505

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    模块

  • 描述:

    VARISTOR MODULE

  • 数据手册
  • 价格&库存
2859505 数据手册
https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) Pluggable type 2 arrester (surge arrester) for 2-phase current supply networks with separate N and PE (4-conductor system: L1, L2, N, PE), with remote indication contact. Overall width: 36 mm. Why buy this product  Plugs can be checked with CHECKMASTER  With or without floating remote indication contact  High continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations  Modular arrester blocks with ultra-narrow design  Use of varistors that are free of leakage current  Disconnect device on each individual plug  Mechanical keying of all slots  Optical, mechanical status indication for the individual arresters  Type 2 consistent plug-in surge arresters       Key commercial data Packing unit 1 Minimum order quantity 1 Catalog page Page 33 (TT-2011) GTIN Custom tariff number 85363030 Country of origin GERMANY Technical data Standards IEC power supply system TT IEC power supply system TN-S Housing material PBT Inflammability class according to UL 94 V0 Color gray Standards for air and creepage distances DIN VDE 0110-1 Standards for air and creepage distances IEC 60664-1 04.10.2012   Page 1 / 7 https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Technical data Standards Standards for air and creepage distances IEC 61643-11 Surge voltage category III Pollution degree 2 Degree of protection IP20 Mounting type DIN rail: 35 mm Design DIN rail module, two-section, divisible Number of positions 3 Ambient temperature (operation) -40 °C ... 80 °C Message: Surge protection fault Optical, remote indicator contact Direction of action 2L-N & N-PE Width 37.25 mm Height 98.5 mm Depth 70 mm Protective circuit IEC category II IEC category T2 EN type T2 Nominal voltage UN 240 V AC (230/400 V AC ... 240/415 V AC) Nominal voltage UN 415 V AC (L-L) Arrester rated voltage UC (L-N) 350 V AC Arrester rated voltage UC (N-PE) 264 V AC UT (TOV-proof) 415 V AC (5 sec.) UT (TOV-proof) 1200 V AC (200 ms / N-PE) Nominal frequency fN 50 Hz Nominal frequency fN 60 Hz Nominal load current IL 40 A (biconnect, 6 mm2) Nominal load current IL 63 A (2 x 10 mm2) Ground conductor current IPE ≤ 1 µA Standby power consumption PC ≤ 3.5 mW Power consumption without load Pc ≤ 3.5 mW Max. discharge surge current Imax (8/20) µs maximum (L-N) 80 kA (all channels) Max. discharge surge current Imax (8/20) µs maximum (N-PE) 40 kA Nominal discharge surge current In (8/20) µs (L-N) 40 kA (all channels) Nominal discharge surge current In (8/20) µs (N-PE) 20 kA Impulse operate voltage at 6 kV (1.2/50)µs (N-PE) ≤ 1.5 kV Protection level UP (L-N) ≤ 1.4 kV Protection level UP (N-PE) ≤ 1.5 kV Residual voltage (L-N) ≤ 1.4 kV (at In) Residual voltage (L-N) ≤ 1.2 kV (at 10 kA) Residual voltage (L-N) ≤ 1.1 kV (at 5 kA) Residual voltage (L-N) ≤ 1 kV (at 3 kA) Residual voltage (L-PE) ≤ 1.6 kV (at In) 04.10.2012   Page 2 / 7 https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Technical data Protective circuit Residual voltage (L-PE) ≤ 1.3 kV (at 10 kA) Residual voltage (L-PE) ≤ 1.2 kV (at 5 kA) Residual voltage (L-PE) ≤ 1.1 kV (at 3 kA) Residual voltage (N-PE) ≤ 0.5 kV (at In) Residual voltage (N-PE) ≤ 0.3 kV (at 10 kA) Residual voltage (N-PE) ≤ 0.25 kV (at 5 kA) Residual voltage (N-PE) ≤ 0.2 kV (at 3 kA) Clamping voltage ringwave (L-N) ≤ 1.2 kV (category C3 20 kV/10 kA) Clamping voltage ringwave (L-N) ≤ 1.1 kV (category C2 10 kV/5 kA) Clamping voltage ringwave (L-N) ≤ 1 kV (category B3/C1 6 kV/3 kA) Clamping voltage ringwave (L-PE) ≤ 1.3 kV (category C3 20 kV/10 kA) Clamping voltage ringwave (L-PE) ≤ 1.2 kV (category C2 10 kV/5 kA) Clamping voltage ringwave (L-PE) ≤ 1.1 kV (category B3/C1 6 kV/3 kA) Clamping voltage ringwave (N-PE) ≤ 1.5 kV (category C3 20 kV/10 kA) Clamping voltage ringwave (N-PE) ≤ 1.4 kV (category C2 10 kV/5 kA) Clamping voltage ringwave (N-PE) ≤ 1.2 kV (category B3/C1 6 kV/3 kA) Response time (L-N) ≤ 25 ns Response time (L-PE) ≤ 100 ns Response time (N-PE) ≤ 100 ns Max. required backup fuse with branch wiring 125 A (gL/gG) Max. required backup fuse with V-type through wiring 40 A (gL/gG) Short-circuit resistance IP with max. backup fuse (effective) 25 kA Follow current quenching capacity If (N-PE) 100 A Connection, protective circuit Connection method Screw connection Connection type IN Biconnect screw terminal block Connection type OUT Biconnect screw terminal block Connection method Biconnect terminal block Screw thread M5 Tightening torque 4.5 Nm Stripping length 16 mm Conductor cross section stranded min. 2.5 mm² Conductor cross section stranded max. 16 mm² Conductor cross section solid min. 2.5 mm² Conductor cross section solid max. 25 mm² Conductor cross section AWG/kcmil min. 12 Conductor cross section AWG/kcmil max 4 Remote indicator contact Connection name Remote fault indicator contact Switching function PDT contact Connection method Pluggable screw connection Screw thread M2 04.10.2012   Page 3 / 7 https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Technical data Remote indicator contact Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section stranded min. 0.14 mm² Conductor cross section stranded max. 1.5 mm² Conductor cross section solid min. 0.14 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section AWG/kcmil min. 28 Conductor cross section AWG/kcmil max 16 Maximum operating voltage Umax. AC 250 V AC Maximum operating voltage Umax DC 125 V DC Max. operating current Imax 1 A AC (inductive) Max. operating current Imax 1 A AC (ohmic) Max. operating current Imax 30 mA DC (inductive) Max. operating current Imax 200 mA DC (ohmic) Min. permissible switching capacity 0.12 VA (12 V, 10 mA) Standards Standards/regulations IEC 61643-1 2005 Standards/regulations DIN EN 61643-11 2002 Standards/regulations DIN EN 61643-11/A11 2007 Standards/regulations IEEE C62.1 / C62.34 / C62.45 Standards/regulations UL 1449 Classifications eclass eCl@ss 4.0 27140201 eCl@ss 4.1 27130801 eCl@ss 5.0 27130801 eCl@ss 5.1 27130801 eCl@ss 6.0 27130805 eCl@ss 7.0 27130805 etim ETIM 2.0 EC000941 ETIM 3.0 EC000941 ETIM 4.0 EC000941 unspsc UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 04.10.2012   Page 4 / 7 https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Classifications unspsc UNSPSC 13.2 39121620 Approvals Approvals Approvals UL Recognized / KEMA-KEUR / cUL Recognized / GOST / IECEE CB Scheme / cULus Recognized Ex Approvals Approvals submitted Approval details UL Recognized  KEMA-KEUR  cUL Recognized  GOST  IECEE CB Scheme  cULus Recognized  Accessories Accessories Bridges 04.10.2012   Page 5 / 7 https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Accessories Wiring bridge - MPB SET VAL-CP-3S - 2880684 Wiring bridge set, consisting of three flexible bridges 15 cm black, 1 bridge 27 cm blue.     Marking Zack Marker strip, flat - ZBF 12:UNBEDRUCKT - 0809735 Zack Marker strip, flat, Strip, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into flat marker groove, For terminal block width: 12 mm, Lettering field: 5.15 x 12.15 mm     Marker pen - X-PEN 0,35 - 0811228 Marker pen without ink cartridge, for manual labeling of markers, labeling extremely wipe-proof, line thickness 0.35 mm     Flat zack marker sheet - ZBFM 5/WH:UNBEDRUCKT - 0803595 Flat zack marker sheet, Sheet, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into flat marker groove, For terminal block width: 5.2 mm, Lettering field: 5 x 4.5 mm     Drawings 04.10.2012   Page 6 / 7 https://www.phoenixcontact.com/us/produkte/2859505 Type 2 surge protection device - VAL-CP-2S-350 - 2859505 Dimensioned drawing Circuit diagram N 98 12 22,5 11 14 FM 64 51,5 71,5 45 PE L1 L2 © Phoenix Contact 2012 - all rights reserved http://www.phoenixcontact.com 04.10.2012   Page 7 / 7
2859505 价格&库存

很抱歉,暂时无法提供与“2859505”相匹配的价格&库存,您可以联系我们找货

免费人工找货