0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2859738

2859738

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    模块

  • 描述:

    VARISTOR MODULE

  • 数据手册
  • 价格&库存
2859738 数据手册
https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://download.phoenixcontact.com) Pluggable lightning current and surge arrester combination, in acc. with typ 1+2 / Class I+II / B+C arresters. Arresters coordinated following the AEC principle, for 1-phase power supply networks with separately installed PE and N (L1, PE, N). Why buy this product  Plugs can be checked with CHECKMASTER  High continuous voltage of 350 V AC for 230/400 V AC networks with high voltage fluctuations  With floating remote indication contact  Thermal disconnect device for each individual plug  Optical, mechanical status indication for the individual arresters       Key commercial data Packing unit 1 Minimum order quantity 1 Catalog page Page 29 (TT-2011) GTIN Custom tariff number 85363030 Country of origin GERMANY Technical data Standards Housing material PBT Inflammability class according to UL 94 V0 Color gray Standards for air and creepage distances DIN VDE 0110-1 Standards for air and creepage distances IEC 60664-1 Standards for air and creepage distances IEC 61643-1 Surge voltage category III Pollution degree 2 Degree of protection IP20 Mounting type DIN rail: 35 mm Design DIN rail module, two-section, divisible 05.10.2012   Page 1 / 7 https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Technical data Standards Number of positions 2 Ambient temperature (operation) -40 °C ... 80 °C Arrester can be tested with CHECKMASTER from software version: From SW rev. 3.00 Message: Surge protection fault Optical, remote indicator contact Direction of action 1L-N & N-PE Width 71.6 mm Height 95.8 mm Depth 70 mm Pitch unit 4 Div. Protective circuit IEC category I + II IEC category T1 + T2 EN type T1 + T2 Lightning protection class III-IV /50 kA (TT, TN-C-S) Nominal voltage UN 240 V AC (230 V AC ... 240 V AC) Arrester rated voltage UC (L-N) 350 V AC Arrester rated voltage UC (N-PE) 350 V AC UT (TOV-proof) ≤ 415 V AC (5 s / L-N) UT (TOV-safe) ≤ 1200 V AC (200 ms / N-PE) Nominal frequency fN 50 Hz (60 Hz) Nominal load current IL 125 A (≤ 55°C) Ground conductor current IPE ≤ 5 µA Standby power consumption PC ≤ 3.5 mW Nominal discharge surge current In (8/20) µs (L-N) 25 kA Nominal discharge surge current In (8/20) µs (N-PE) 100 kA Lightning test current (10/350) µs, charge 25 As Lightning test current (10/350) µs, specific energy 625.00 kJ/Ω Lightning test current (10/350) µs, peak value limp 50 kA Lightning test current (10/350) µs, charge 50 As Lightning test current (10/350) µs, specific energy 2.50 MJ/Ω Lightning test current (10/350) µs, peak value limp 100 kA (N-PE) Impulse operate voltage at 6 kV (1.2/50)µs (N-PE) ≤ 1.5 kV Protection level UP (L-N) ≤ 1.5 kV Protection level UP (N-PE) ≤ 1.5 kV Residual voltage (L-N) ≤ 1.3 kV (at In) Residual voltage (L-N) ≤ 1.1 kV (at 10 kA) Residual voltage (L-N) ≤ 1 kV (at 5 kA) Residual voltage (L-N) ≤ 1 kV (at 3 kA) Residual voltage (L-PE) ≤ 2.2 kV (at In) Residual voltage (L-PE) ≤ 2 kV (at 10 kA) Residual voltage (L-PE) ≤ 1.8 kV (at 5 kA) Residual voltage (L-PE) ≤ 1.6 kV (at 3 kA) 05.10.2012   Page 2 / 7 https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Technical data Protective circuit Residual voltage (N-PE) ≤ 1.5 kV (at In) Residual voltage (N-PE) ≤ 1 kV (at 10 kA) Residual voltage (N-PE) ≤ 0.9 kV (at 5 kA) Residual voltage (N-PE) ≤ 0.8 kV (at 3 kA) Response time (L-N) ≤ 25 ns Response time (L-PE) ≤ 100 ns Response time (N-PE) ≤ 100 ns Max. required backup fuse with branch wiring 315 A (gL/gG) Max. required backup fuse with V-type through wiring 125 A (gL/gG) Recommended backup fuse maximum 160 A (gL/gG, 125 A with serial through wiring) Short-circuit resistance IP with max. backup fuse (effective) 25 kA Short-circuit current self-quenching 100 A (effective (N-PE)) Follow current quenching capacity If 100 A (350 V AC (N-PE)) Follow current quenching capacity If (L-N) 25 kA (264 V AC) Follow current quenching capacity If (L-N) 3 kA (350 V AC) Follow current quenching capacity If (N-PE) 100 A Connection, protective circuit Connection method Screw terminal blocks Connection type IN Biconnect screw terminal block Connection type OUT Biconnect screw terminal block Connection method Biconnect terminal block Screw thread M5 Tightening torque 4.5 Nm Stripping length 18 mm Conductor cross section stranded min. 2.5 mm² Conductor cross section stranded max. 25 mm² Conductor cross section solid min. 2.5 mm² Conductor cross section solid max. 35 mm² Conductor cross section AWG/kcmil min. 13 Conductor cross section AWG/kcmil max 2 Remote indicator contact Connection name Remote fault indicator contact Switching function PDT contact Connection method Plug-in/screw connection via COMBICON Screw thread M2 Tightening torque 0.25 Nm Stripping length 7 mm Conductor cross section stranded min. 0.14 mm² Conductor cross section stranded max. 1.5 mm² Conductor cross section solid min. 0.14 mm² Conductor cross section solid max. 1.5 mm² Conductor cross section AWG/kcmil min. 28 05.10.2012   Page 3 / 7 https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Technical data Remote indicator contact Conductor cross section AWG/kcmil max 16 Maximum operating voltage Umax. AC 250 V AC Maximum operating voltage Umax DC 125 V DC Max. operating current Imax 1 A AC (inductive) Max. operating current Imax 1 A AC (ohmic) Max. operating current Imax 30 mA DC (inductive) Max. operating current Imax 200 mA DC (ohmic) Standards Standards/regulations IEC 61643-1 2002 Standards/regulations EN 61643-11 2005 Standards/regulations UL 1449 Classifications eclass eCl@ss 4.0 27140201 eCl@ss 4.1 27140201 eCl@ss 5.0 27140201 eCl@ss 5.1 27140201 eCl@ss 6.0 27140201 eCl@ss 7.0 27140201 etim ETIM 2.0 EC001457 ETIM 3.0 EC001457 ETIM 4.0 EC001457 ETIM 5.0 EC001457 unspsc UNSPSC 6.01 30212010 UNSPSC 7.0901 39121610 UNSPSC 11 39121610 UNSPSC 12.01 39121610 UNSPSC 13.2 39121620 Approvals Approvals Approvals UL Recognized / KEMA-KEUR / cUL Recognized / GOST / CCA / IECEE CB Scheme / GL / cULus Recognized 05.10.2012   Page 4 / 7 https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Approvals Ex Approvals Approvals submitted Approval details UL Recognized  KEMA-KEUR  cUL Recognized  GOST  CCA  IECEE CB Scheme  GL  cULus Recognized  Accessories Accessories Marking Zack marker strip - ZBN 18:UNBEDRUCKT - 2809128 Zack marker strip, Strip, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into tall marker groove, For terminal block width: 18 mm, Lettering field: 18 x 5 mm     05.10.2012   Page 5 / 7 https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Accessories Zack marker strip - ZBN 18,LGS:L1-N,ERDE - 2749576 Zack marker strip, Strip, white, Labeled, Horizontal: L1, L2, L3, N, GND, Mounting type: Snap into tall marker groove, For terminal block width: 18 mm, Lettering field: 18 x 5 mm     Zack marker strip - ZBN 18,LGS:ERDE - 2749589 Zack marker strip, Strip, white, Labeled, Horizontal: Grounding symbol, Mounting type: Snap into tall marker groove, For terminal block width: 18 mm, Lettering field: 18 x 5 mm     Marker pen - B-STIFT - 1051993 Marker pen, for manual labeling of unprinted Zack strips, smear-proof and waterproof, line thickness 0.5 mm     Flat zack marker sheet - ZBFM 5/WH:UNBEDRUCKT - 0803595 Flat zack marker sheet, Sheet, white, Unlabeled, Can be labeled with: Plotter, Mounting type: Snap into flat marker groove, For terminal block width: 5.2 mm, Lettering field: 5 x 4.5 mm     Type 1 surge protection connector - FLT-CP-N/PE-350-ST - 2859686 Type 1 / Class I / B arrester (lightning arrester) replacement plug for path N-PE, can be combined with FLASHTRAB compact series of products.     05.10.2012   Page 6 / 7 https://www.phoenixcontact.com/us/produkte/2859738 Type 1/2 surge protection device - FLT-CP-1S-350 - 2859738 Accessories Type 2 surge protection connector - VAL-CP-350-ST - 2859602 Type 2 arrester replacement plug (surge arrester) with high-capacity varistor with low leakage current.     Drawings Dimensioned drawing Circuit diagram 11 14 FM 64 22,5 51,5 71,5 45 12 N 95 PE L1 © Phoenix Contact 2012 - all rights reserved http://www.phoenixcontact.com 05.10.2012   Page 7 / 7
2859738 价格&库存

很抱歉,暂时无法提供与“2859738”相匹配的价格&库存,您可以联系我们找货

免费人工找货