2861292 数据手册
IB IL 24 DO 16 ... 1 2 1 2 Inline Terminal With 16 Digital Outputs D 1 2 3 4 DO 16 1 2 3 4 3 4 3 4 4x AUTOMATIONWORX Data Sheet 5559_en_05 © PHOENIX CONTACT - 09/2007 Description The terminal is designed for use within an Inline station. It is used to output digital signals. Features – – – – – – – Connections for 16 digital actuators Connection of actuators in 2 and 3-wire technology Nominal current per output: 0.5 A Total current of the terminal: 8 A Short-circuit and overload protected outputs Diagnostic and status indicators IB IL 24 DO 16, IB IL 24 DO 16-PAC and IB IL 24 DO 16-PAC/SN: Approved for the use in potentially explosive areas (observe the notes on page 8) This data sheet is only valid in association with the IL SYS INST UM E user manual or the Inline system manual for your bus system. Please note that the numbering of the terminal points differs with regard to the different connector versions, Figure 2 on page 7. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for the products listed on the following page: IB IL 24 DO 16 ... Ordering Data Products Description Type Order No. Pcs./Pkt. Inline terminal with 16 digital outputs; complete with accessories (connector and labeling fields); transmission speed of 500 kbps IB IL 24 DO 16-PAC 2861292 1 Inline terminal with 16 digital outputs; complete with accessories (connector with individual numbering and labeling fields); transmission speed of 500 kbps IB IL 24 DO 16-PAC/SN 2862961 1 Inline terminal with 16 digital outputs; without accessories; transmission speed of 500 kbps IB IL 24 DO 16 2726272 1 Inline terminal with 16 digital outputs; complete with accessories (connector and labeling fields); transmission speed of 2 Mbps IB IL 24 DO 16-2MBD-PAC 2862013 1 Inline terminal with 16 digital outputs; complete with accessories (connector with individual numbering and labeling fields); transmission speed of 2 Mbps IB IL 24 DO 16-2MBD-PAC/SN 2878324 1 Inline terminal with 16 digital outputs; without accessories; transmission speed of 2 Mbps IB IL 24 DO 16-2MBD 2855318 1 Four of the listed connectors or one connector set are needed for the complete fitting of the IB IL 24 DO 16 and IB IL 24 DO 16-2MBD terminals. Accessories Description Type Order No. Pcs./Pkt. Connector, without color print, for digital 4-channel or 16-channel Inline terminals IB IL SCN-12 2726340 10 Connector, with color print, for digital 4-channel or 16-channel Inline terminals IB IL SCN-12-OCP 2727624 10 Connector set with 48 spring-cage connections (green, w/o color print) IB IL DI/DO 16-PLSET 2860976 1 Connector set with 48 spring-cage connections (green, with color print) IB IL DO 16-PLSET/OCP 2860992 1 Description Type Order No. Pcs./Pkt. "Automation Terminals of the Inline Product Range" user manual IL SYS INST UM E 2698737 1 "Configuring and Installing the INTERBUS Inline Product Range" user manual IB IL SYS PRO UM E 2743048 1 Documentation "INTERBUS Addressing" data sheet DB GB IBS SYS ADDRESS 9000990 1 "Inline Terminals for Use in Zone 2 Potentially Explosive Areas" application note AH EN IL EX ZONE 2 7217 1 "Addressing of 16-Channel Modules" application note AH IB IL 24 DI/DO 16 ADDRESS 9014124 1 5559_en_05 PHOENIX CONTACT 2 IB IL 24 DO 16 ... Technical Data General Data Housing dimensions (width x height x depth) 48.8 mm x 120 mm x 71.5 mm Weight 130 g (without connector), 152 g (with connector) Operating mode Process data mode with 1 word Connection method for actuators 2 and 3-wire technology Ambient temperatures (operation) -25°C to +55°C Ambient temperature (storage/transport) -25°C to +85°C Permissible humidity (operation/storage/transport) 10% to 95% according to DIN EN 61131-2 Permissible air pressure (operation/storage/transport) 70 kPa to 106 kPa (up to 3000 m above sea level) Degree of protection IP20 according to IEC 60529 Class of protection Class 3 according to EN 61131-2, IEC 61131-2 Connection data for Inline connector Connection type Spring-cage terminals Conductor cross-section 0.2 mm2 to 1.5 mm2 (solid or stranded), 24 - 16 AWG Interface Local bus Through data routing Transmission Speed IB IL 24 DO 16-PAC 500 kbps IB IL 24 DO 16-PAC/SN 500 kbps IB IL 24 DO 16 500 kbps IB IL 24 DO 16-2MBD-PAC 2 Mbps IB IL 24 DO 16-2MBD-PAC/SN 2 Mbps IB IL 24 DO 16-2MBD 2 Mbps Supply of the Module Electronics and I/O Through Bus Coupler/Power Terminal Connection method Via potential routing Power Consumption 500 kbps Communications power 7.5 V DC 7.5 V DC Current consumption at UL 90 mA, maximum 105 mA, maximum 2 Mbps Power consumption at UL 0.675 W, maximum 0.79 W, maximum Segment supply voltage US 24 V DC (nominal value) 24 V DC (nominal value) Nominal current consumption at US 8 A (16 x 0.5 A), maximum 8 A (16 x 0.5 A), maximum Digital Outputs Number 16 Nominal output voltage UOUT 24 V DC Differential voltage for Inom ≤1V Nominal current Inom per channel 0.5 A Tolerance of the nominal current +10% Total current 8A Protection Short circuit; overload Always 4 channels are thermally coupled, i.e., an error case in one channel can affect the other channels. Nominal load Ohmic 48 Ω / 12 W Lamp 12 W Inductive 12 VA (1.2 H, 50 Ω) 5559_en_05 PHOENIX CONTACT 3 IB IL 24 DO 16 ... Digital Outputs (Continued) Signal delay upon power up of: Nominal ohmic load 500 μs, typical Nominal lamp load 100 ms, typical (with switching frequencies up to 8 Hz; above this frequency the lamp load responds like an ohmic load) Nominal inductive load 100 ms (1.2 H, 50 Ω), typical Signal delay upon power down of: Nominal ohmic load 1 ms, typical Nominal lamp load 1 ms, typical Nominal inductive load 50 ms (1.2 H, 50 Ω), typical Switching frequency with Nominal ohmic load 300 Hz, maximum This switching frequency is limited by the selected data rate, the number of bus devices, the bus structure, the software and the control or computer system used. Nominal lamp load 8 Hz, maximum This switching frequency is limited by the selected data rate, the number of bus devices, the bus structure, the software and the control or computer system used. 0.5 Hz (1.2 H, 50 Ω), maximum Nominal inductive load Overload response Auto restart Response time with ohmic overload (12 Ω) 3 s, approximately Restart frequency with ohmic overload 400 Hz, approximately Restart frequency with lamp overload 400 Hz, approximately Response with inductive overload Output may be damaged Response time in the event of a short circuit 3 s, approximately Reverse voltage protection against short pulses Protected against reverse voltages Resistance to permanently applied reverse voltages Protected against reverse voltages, permissible current 2 A, maximum Validity of output data after connecting the 24 V supply voltage (power up) 5 ms, typical Response upon power down The output follows the supply voltage without delay. Limitation of the voltage induced on circuit interruption -15 V ≤ Udemag ≤ -45.8 V (Udemag = demagnetization voltage) One-time unsolicited energy 400 mJ, maximum Protective circuit type Integrated 45 V Zener diode in the output chip Overcurrent circuit 0.7 A, minimum Output current when switched off 300 μA, maximum Output voltage when switched off 2 V, maximum Output current with ground connection interrupt 25 mA, maximum Switching power with ground connection interrupt 100 mW at 1 kΩ load resistance, typical Inrush current with lamp load 1.5 A for 20 ms, maximum Output Characteristic Curve When Switched On (Typical) Output Current (A) 5559_en_05 Output Voltage Difference (V) 0 0 0.1 0.04 0.2 0.08 0.3 0.12 0.4 0.16 0.5 0.20 PHOENIX CONTACT 4 IB IL 24 DO 16 ... Power Dissipation 500 kbps 2 Mbps Formulas to Calculate the Power Dissipation of the Electronics n n PEL = 0.19 W + S (0.10 W + ILi x 0.4 W) PEL = 0.40 W + S (0.10 W + ILi x 0.4 W) 2 2 i=1 i=1 Where PEL Total power dissipation in the terminal i Continuous index n Number of set outputs (n = 1 to 16) ILi Load current of the output i Power Dissipation of the Housing PHOU (500 kbps and 2 Mbps) 2.7 W, maximum (within the permissible operating temperature) Limitation of Simultaneity, Derating (500 kbps and 2 Mbps) Ambient Temperature TA Maximum Load Current at 100% Simultaneity Maximum Load Current at 75% Simultaneity -25°C ≤ TA < +40°C 0.50 0.50 +40°C ≤ TA < +45°C 0.45 0.50 +45°C ≤ TA < +50°C 0.40 0.50 +50°C ≤ TA < +55°C 0.35 0.50 Safety Equipment Overload/short circuit in segment circuit Electronic; with four 4-channel drivers Surge voltage Protective elements of the power terminal Protection up to 33 V DC Polarity reversal of the supply voltage Protective elements of the power terminal The supply voltage must be protected. The power supply unit should be able to supply four times (400%) the nominal current of the fuse. Reverse voltage Integrated protection against reverse voltages Electrical Isolation/Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I/O area it is necessary to supply the station bus coupler and the digital output terminal described here via the bus coupler or a power terminal from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted. (See also user manual.) Common Potentials The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. Separate Potentials in the System Consisting of Bus Coupler/Power Terminal and I/O Terminal Test Distance Test Voltage 5 V supply incoming remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min 5 V supply outgoing remote bus/7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min 7.5 V supply (bus logic)/24 V supply (I/O) 500 V AC, 50 Hz, 1 min 24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min 5559_en_05 PHOENIX CONTACT 5 IB IL 24 DO 16 ... Error Messages to the Higher-Level Control or Computer System Short circuit/overload of an output Yes An error message is generated when an output is short circuited and switched on. In addition, the diagnostic LED (D) flashes on the terminal at 2 Hz (medium) under these conditions. Falling below or exceeding the operating voltage No Approvals For the latest approvals, please visit www.download.phoenixcontact.com or www.eshop.phoenixcontact.com. 5559_en_05 PHOENIX CONTACT 6 IB IL 24 DO 16 ... Local Diagnostic and Status Indicators and Terminal Point Assignment Local Diagnostic and Status Indicators Terminal Point Assignment for Each Connector A D 1 1 2 1 3 2 4 3 2 4 3 x 2 3 4 B 4 x 1 4 D O 1 6 1 2 x x 1 .1 1 1 2 .1 1 .1 1 1 .2 2 2 2 .2 1 .2 2 1 .3 3 3 2 .3 1 .3 3 1 .4 4 4 2 .4 1 .4 4 1 2 1 .1 2 .1 Figure 1 1 .2 3 .1 4 .1 2 .2 1 .3 3 .2 2 .3 5 5 2 .5 1 .5 5 1 .6 6 6 2 .6 1 .6 6 3 .4 4 .5 2 .6 3 .6 1 x 8 .1 2 8 .2 3 8 .3 4 8 .4 5 8 .5 6 8 .6 8 .2 8 .3 3 3 7 .4 6 .4 8 .4 4 4 5 .5 4 .6 8 .1 7 .3 6 .3 6 .5 7 .5 8 .5 5 5 5 5 5 .6 6 .6 6 6 6 6 7 .1 7 .2 6 .2 4 4 3 .5 2 2 2 5 .4 4 .4 1 1 1 3 3 5 5 1 .6 6 .1 5 .3 4 .3 4 4 2 .5 5 .1 2 2 3 .3 2 .4 2 5 .2 4 .2 3 3 1 .4 1 1 1 2 2 1 .5 Diagnostic and status indicators 2 1 1 1 .5 5 5 5 9 C 0 0 2 1 7 .6 6 6 8 .6 5 5 5 9 B 0 0 7 Des. D 1, 2, 3, 4 Color Meaning Green Diagnostics Yellow Status indicators of the outputs Figure 2 A – Function Identification Pink – 2 Mbps: white stripe in the vicinity of the D LED B – – Terminal point numbering: individual connectors (A) and connector sets (B) Using the IB IL 24 DO 16-PAC/SN or IB IL 24 DO 16-2MBD-PAC/SN with the supplied connectors Using individual connectors (IB IL SCN-12 or IB IL SCN-12-OCP) Using the IB IL 24 DO 16-PAC or IB IL 24 DO 16-2MBD-PAC with the original connector set Using the IB IL DO 16-PLSET/OCP or IB IL DI/DO 16-PLSET connector sets Terminal Point Assignment 5559_en_05 x.1 Signal output (OUT) x.2 Ground contact (GND) for 2 and 3-wire termination x.3 FE connection for 3-wire termination x.4 Signal output (OUT) x.5 Ground contact (GND) for 2 and 3-wire termination x.6 FE connection for 3-wire termination PHOENIX CONTACT 7 IB IL 24 DO 16 ... Notes on Using the Terminal in Potentially Explosive Areas for the IB IL 24 DO 16, IB IL 24 DO 16-PAC, and IB IL 24 DO 16-PAC/SN Terminals Approval According to EC Directive 94/9 (ATEX) II 3G Ex nAC IIC T4 X This Inline terminal conforms to the requirements of protection type "n" and can be installed in a zone 2 potentially explosive area. This Inline terminal is a category 3G item of electrical equipment. WARNING: Explosion hazard Only Inline terminals that are approved for use in potentially explosive areas may be snapped next to this Inline terminal. Before using an Inline terminal in a zone 2 potentially explosive area, check that the terminal has been approved for installation in this area. For a list of terminals approved for zone 2 potentially explosive areas, please refer to the AH EN IL EX ZONE 2 application note. Check the labeling on the Inline terminal and the packaging (see Figure 3). WARNING: Explosion hazard Before startup, ensure that the following points and instructions are observed. 1. 2. 3. 4. 5. 6. 7. II 3G Ex nAC IIC T4 X Potential routing 4 A maximum for use in Ex areas IBx IL xx xx x Order-No.: xxxxxxx Module-ID: xx HW/FW XX/INTERBUS Figure 3 GL UL xx LISTED 31ZN When working on the Inline terminal, always disconnect the supply voltage. The Inline terminal must only be installed, started up, and maintained by qualified specialist personnel. Install the Inline terminals in a control cabinet or metal housing. The minimum requirement for both items is IP54 protection according to EN 60529. The Inline terminal must not be subject to mechanical strain or thermal loads, which exceed the limits specified in the product documentation. The Inline terminal must not be repaired by the user. Repairs may only be carried out by the manufacturer. The Inline terminal is to be replaced by an approved terminal of the same type. Only category 3G equipment may be connected to Inline terminals in zone 2. Observe all applicable standards and national safety and accident prevention regulations for installing and operating equipment. Restrictions Proc. Ctrl. Eqpt. For Haz. Locs. Cl. I, Zn. 2, AEx nC IIC T5 Cl. I, Zn. 2, Ex nC IIC T5 Cl. I, Div. 2, Grp. A,B,C,D T5 5561C001 Typical labeling of terminals for use in potentially explosive areas WARNING: Explosion hazard When using terminals in potentially explosive areas, observe the technical data and limit values specified in the corresponding documentation (user manual, data sheet, package slip). WARNING: Explosion hazard Restrictions regarding the Inline system The maximum permissible current flowing through the potential jumpers UM and US (total current) is limited to 4 A when using the Inline terminal in potentially explosive areas. 5559_en_05 PHOENIX CONTACT 8 IB IL 24 DO 16 ... Internal Circuit Diagram L o c a l b u s O P C U L 6 4 2 + 2 4 V (U + 2 4 V (U 2 2 ) S M 2 8 ) 5 5 5 9 B 0 0 3 Figure 4 Internal wiring of the terminal points Key: OPC Protocol chip (bus logic including voltage conditioning) LED Optocoupler Transistor Digital output Electrically isolated area Other symbols used are explained in the IL SYS INST UM E user manual or in the Inline system manual for your bus system. 5559_en_05 PHOENIX CONTACT 9 IB IL 24 DO 16 ... Connection Example Programming Data/Configuration Data Local Bus (INTERBUS) When connecting the actuators observe the assignment of the terminal points to the process data (see page 11). 1 1 D 2 1 1 2 3 1 2 3 4 4 3 2 2 3 4 3 4 ID code BDhex (189dec) Length code 01hex Process data channel 16 bits Input address area 0 words Output address area 1 word Parameter channel (PCP) 0 words Register length (bus) 1 word 4 DO16 Other Bus Systems 1 2 1 2 1 2 11 11 11 1 2 22 22 22 2 3 33 33 33 3 4 44 44 44 4 5 55 55 55 5 6 66 66 66 6 For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). OUT14 1 Figure 5 OUT16 OUT3 A A B 1 OUT1 A 2 A B 7375A004 Typical actuator connection 3-wire termination 2-wire termination The numbers above the module illustration identify the connector slots. 5559_en_05 PHOENIX CONTACT 10 IB IL 24 DO 16 ... Process Data For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. For the assignment of the illustrated (byte.bit) view to control systems of other bus systems, please refer to the AH IB IL 24 DI/DO 16 ADDRESS document. Assignment of the Terminal Points to the OUT Process Data The following table applies to the IB IL 24 DO 16-PAC and IB IL 24 DO 16-2MBD-PAC terminals with the original connector set and when using the connector sets IB IL DI/DO 16-PLSET or IB IL DO 16-PLSET/OCP (see also Figure 2 on page 7, detail B). (Byte.bit) view Byte Assignment Slot Byte 0 Bit Status indicators 7 6 5 4 3 Byte 1 2 4 1 0 7 6 3 5 4 3 2 2 1 0 1 Terminal point (signal) 8.4 7.4 8.1 7.1 6.4 5.4 6.1 5.1 4.4 3.4 4.1 3.1 2.4 1.4 2.1 1.1 Terminal point (GND) 8.5 7.5 8.2 7.2 6.5 5.5 6.2 5.2 4.5 3.5 4.2 3.2 2.5 1.5 2.2 1.2 Terminal point (FE) 8.6 7.6 8.3 7.3 6.6 5.6 6.3 5.3 4.6 3.6 4.3 3.3 2.6 1.6 2.3 1.3 Slot 4 LED 4 3 3 2 1 4 3 2 2 1 4 3 1 2 1 4 3 2 1 The following table applies to the IB IL 24 DO 16-PAC/SN and IB IL 24 DO 16-2MBD-PAC/SN terminals with the original connector set and when using the IB IL SCN-12 or IB IL SCN-12-OPC connectors (see also Figure 2 on page 7, detail A). (Byte.bit) view Byte Byte 0 Bit Assignment Status indicators 7 6 Slot 5 4 3 Byte 1 2 4 1 0 7 6 3 5 4 3 2 2 1 0 1 Terminal point (signal) 2.4 1.4 2.1 1.1 2.4 1.4 2.1 1.1 2.4 1.4 2.1 1.1 2.4 1.4 2.1 1.1 Terminal point (GND) 2.5 1.5 2.2 1.2 2.5 1.5 2.2 1.2 2.5 1.5 2.2 1.2 2.5 1.5 2.2 1.2 Terminal point (FE) 2.6 1.6 2.3 1.3 2.6 1.6 2.3 1.3 2.6 1.6 2.3 1.3 2.6 1.6 2.3 1.3 Slot LED 4 4 3 3 2 1 4 3 2 2 1 4 3 1 2 1 4 3 2 1 © PHOENIX CONTACT 09/2007 5559_en_05 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany Phone: +49-(0) 5235-3-00 • Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com 11
2861292 价格&库存

很抱歉,暂时无法提供与“2861292”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2861292
  •  国内价格
  • 1+2288.56566

库存:2