    INPUT MODULE 2 DIGITAL

  • 数据手册
  • 价格&库存
2861713 数据手册
IB IL 24 DI 2 ... D 1 2 Inline Terminal With Two Digital Inputs DI2 AUTOMATIONWORX Data Sheet 5549_en_03 © PHOENIX CONTACT - 09/2006 Description The terminal is designed for use within an Inline station. It is used to acquire digital input signals. Features – – – – – Connections for two digital sensors Connection of sensors in 2, 3, and 4-wire technology Maximum permissible load current per sensor: 250 mA Maximum permissible load current from the terminal: 0.5 A Diagnostic and status indicators This data sheet is only valid in association with the IB IL SYS PRO UM E user manual or the Inline system manual for your bus system. Make sure you always use the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. This data sheet is valid for the products listed on the following page: IB IL 24 DI 2 ... Ordering Data Products Description Type Order No. Pcs./Pck. Inline terminal with two digital inputs; including accessories (connectors and labeling field); transmission speed 500 kbps IB IL 24 DI 2-PAC 2861221 1 Inline terminal with two digital inputs; without accessories transmission speed 500 kbps IB IL 24 DI 2 2726201 1 Inline terminal with two digital inputs; without accessories; transmission speed 2 Mbps IB IL 24 DI 2-2MBD 2819066 1 Inline terminal with two digital inputs; including accessories (connectors and labeling field); transmission speed 2 Mbps IB IL 24 DI 2-2MBD-PAC 2861713 1 One of the listed connectors is needed for the complete fitting of the IB IL 24 DI 2 and IB IL 24 DI 2-2MBD terminals. Accessories Description Type Order No. Pcs./Pck. Connector with eight spring-cage connections (green, w/o color print) IB IL SCN-8 2726337 10 Connector with eight spring-cage connections (green, with color print) IB IL SCN-8-CP 2727608 10 Documentation Description Type Order No. Pcs./Pck. "Configuring and Installing the INTERBUS Inline Product Range" user manual IB IL SYS PRO UM E 2743048 1 "Automation Terminals of the Inline Product Range" user manual IL SYS INST UM E 2698737 1 Technical Data General Data Housing dimensions (width x height x depth) 12.2 mm x 120 mm x 71.5 mm Weight 53 g (with connector); 38 g (without connector) Mode of operation Process data mode with 2 bits Connection method for sensors 2, 3, and 4-wire technology Permissible temperature (operation) -25°C to +55°C Permissible temperature (storage/transport) -25°C to +85°C Permissible humidity (operation/storage/transport) 10% / 95% according to EN 61131-2 Permissible air pressure (operation/storage/transport) 70 kPa to 106 kPa (up to 3000 m above sea level) Degree of protection IP20 according to IEC 60529 Class of protection Class 3 according to VDE 0106, IEC 60536 Connection data for Inline Connectors Connection type Spring-cage terminals Conductor cross section 0.2 mm2 to 1.5 mm2 (solid or stranded) Interface Local bus Through data routing Transmission Speed IB IL 24 DI 2, IB IL 24 DI 2-PAC 500 kbps IB IL 24 DI 2-2MBD, IB IL 24 DI 2-2MBD-PAC 2 Mbps 5549_en_03 PHOENIX CONTACT 2 IB IL 24 DI 2 ... Power Consumption (500 kbps) Communications power 7.5 V Current consumption at UL 35 mA, maximum Power consumption at UL 0.27 W, maximum Segment supply voltage US 24 V DC (nominal value) Nominal current consumption at US 0.5 A (2 x 0.25 A), maximum Power Consumption (2 Mbps) Communications power 7.5 V Current consumption at UL 50 mA, maximum Power consumption at UL 0.375 W, maximum Segment supply voltage US 24 V DC (nominal value) Nominal current consumption at US 0.5 A (2 x 0.25 A), maximum Supply of the Module Electronics and I/O Through the Bus Coupler/Power Terminal Connection method Through potential routing Digital Inputs Number 2 Input design According to EN 61131-2 Type 1 Definition of switching thresholds Maximum low-level voltage ULmax < 5 V Minimum high-level voltage UHmin > 15 V Common potentials Segment supply, ground Nominal input voltage UIN 24 V DC Permissible range -3 V < UIN < +30 V DC Nominal input current for UIN (at 500 kbps) 5 mA Nominal input current for UIN (at 2 Mbps) 3 mA, minimum Current flow (500 kbps) Linear in range 1 V < UIN < 30 V Current flow (2 Mbps) See table "Characteristic Curve (at 2 Mbps): Current Depending on the Input Voltage and the Ambient Temperature TA" on page 4 Delay time None Permissible cable length to the sensor 30 m Use of AC sensors AC sensors in the voltage range < UIN are limited in application Input Characteristic Curve (500 kbps) Input Voltage (V) 5549_en_03 Typical Input Current (mA) -3 < UIN < 0.7 0 3 0.4 6 1.0 9 1.7 12 2.3 15 3.0 18 3.7 21 4.4 24 5.0 27 5.7 30 6.4 PHOENIX CONTACT 3 IB IL 24 DI 2 ... Characteristic Curve (at 2 Mbps): Current Depending on the Input Voltage and the Ambient Temperature TA Supply Voltage Input Current Input Current acc. to t >= 20 s for TA = 25°C for TA = 55°C 18 V 3.0 mA 2.9 mA 24 V 3.9 mA 3.8 mA 2.5 mA 3.5 mA 30 V 4.5 mA 4.2 mA 3.0 mA The current is reduced depending on the ambient temperature TA and the number of inputs that are switched on (module internal temperature). Power Dissipation Formula to Calculate the Power Dissipation of the Electronics 500 kbps 2 Mbps 2 PEL = 0.21 W + S [ UINn x n=1 Where PEL n UINn UINn -1.8 V ] 4400 W P E L = 0 .3 7 5 W + S 2 n = 1 [ U IN n x 0 .0 0 3 A ] Total power dissipation in the terminal Index of the number of set inputs n = 1 to 2 Input voltage of the input n Power Dissipation of the Housing PHOU 0.6 W (within the permissible operating temperature) Limitation of Simultaneity, Derating Derating No limitation of simultaneity, no derating Safety Equipment Overload in segment circuit No Surge voltage Protective elements of the power terminal Polarity reversal Protective elements of the power terminal Electrical Isolation/Isolation of the Voltage Areas To provide electrical isolation between the logic level and the I/O area it is necessary to supply the station bus coupler and the digital input terminal via the bus coupler or a power terminal from separate power supply units. Interconnection of the power supply units in the 24 V area is not permitted. (See also user manual.) Common Potentials The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area. Separate Potentials in the System Consisting of Bus Coupler/Power Terminal and I/O Terminal - Test Distance - Test Voltage 5 V supply incoming remote bus / 7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min 5 V supply outgoing remote bus / 7.5 V supply (bus logic) 500 V AC, 50 Hz, 1 min 7.5 V supply (bus logic) / 24 V supply (I/O) 500 V AC, 50 Hz, 1 min 24 V supply (I/O) / functional earth ground 500 V AC, 50 Hz, 1 min Error Messages to the Higher-Level Control or Computer System None Approvals Information on current approvals can be found on the Internet at www.download.phoenixcontact.com. 5549_en_03 PHOENIX CONTACT 4 IB IL 24 DI 2 ... Local Diagnostic and Status Indicators and Terminal Point Assignment 1 Internal Circuit Diagram Local bus D 2 OPC DI 2 UL D 1 2 DI2 1 2 1.1 1 1 2.1 1.2 2 2 2.2 1.3 3 3 2.3 1.4 4 4 +24 V (US) +24 V (UM) 2.4 5549A002 Figure 1 Terminal with appropriate connectors 5549A003 Local Diagnostic and Status Indicators Desig. Color Meaning D Green Diagnostics 1, 2 Yellow Status indicators of the inputs Figure 2 Key: OPC Function identification Light blue Internal wiring of the terminal points Protocol chip (bus logic including voltage conditioning) LED 2 Mbps: white stripe in the vicinity of the D LED Terminal Point Assignment Terminal Point 1.1, 2.1 1.2, 2.2 1.3, 2.3 1.4, 2.4 5549_en_03 Assignment Signal input (IN) Segment voltage US for 2, 3, and 4-wire termination Ground contact (GND) for 3 and 4-wire termination FE connection for 4-wire termination Optocoupler Digital input Electrically isolated area Other symbols used are explained in the IB IL SYS PRO UM E user manual or in the Inline system manual for your bus system. PHOENIX CONTACT 5 IB IL 24 DI 2 ... Connection Example Programming Data/Configuration Data When connecting the sensors observe the assignment of the terminal points to the process data (see page 6). D 1 INTERBUS ID code BEhex (190dec) Length code C2hex Process data channel 2 bits Input address area 2 bits Output address area 0 bits Parameter channel (PCP) 0 bits Register length (bus) 2 bits 2 Other Bus Systems D I 2 For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). 2 1 1 2 2 3 3 4 4 Process Data Figure 3 Byte.bit 0.1 0.0 Module Terminal point (signal) 2.1 1.1 Terminal point (+24 V) 2.2 1.2 Terminal point (GND) 2.3 1.3 Terminal point (FE) 2.4 1.4 LED 2 2 B Typical sensor connections 4-wire termination 3-wire termination (Byte.bit) view IN + 2 4 V A A B Assignment of the Terminal Points to the IN Process Data + 2 4 V IN 1 1 5 5 4 9 A 0 0 4 Status indicator 1 For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet, Order No. 9000990. © PHOENIX CONTACT 09/2006 5549_en_03 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany Phone: +49-(0) 5235-3-00 • Fax: +49-(0) 5235-3-4 12 00 www.phoenixcontact.com 6
2861713 价格&库存

很抱歉,暂时无法提供与“2861713”相匹配的价格&库存,您可以联系我们找货

免费人工找货