IB IL 24 DO 8 ...
Inline terminal with eight digital outputs
4 x
AUTOMATION
Data sheet
5558_en_08
1
© PHOENIX CONTACT 2010-11-23
Description
This terminal is designed for use within an Inline station. It is
used to output digital signals.
Features
–
–
–
–
–
–
–
Connections for eight digital actuators
Connection of actuators in 2, 3, and 4-wire technology
Nominal current of each output: 0.5 A
Total current of the terminal: 4 A
Short-circuit and overload protected outputs
Diagnostic and status indicators
Approved for use within a safety-related segment circuit
(observe the notes on page 8)
This data sheet is only valid in association with the IL SYS INST UM E user manual.
Make sure you always use the latest documentation.
It can be downloaded at www.phoenixcontact.net/catalog.
This data sheet is valid for all products listed on the following page:
IB IL 24 DO 8 ...
2
Ordering data
Products
Description
Type
Order No.
Pcs./Pkt.
Terminal with eight digital outputs;
complete with accessories (connectors consecutively numbered and labeling
fields);
transmission speed of 500 kbps
IB IL 24 DO 8-PAC
2861289
1
Terminal with eight digital outputs;
complete with accessories (connectors not consecutively numbered and labeling fields);
transmission speed of 500 kbps
IB IL 24 DO 8-PAC/SN
2862945
1
Terminal with eight digital outputs; without accessories;
transmission speed of 500 kbps
IB IL 24 DO 8
2726269
1
Terminal with eight digital outputs;
complete with accessories (connectors consecutively numbered and labeling
fields);
transmission speed of 2 Mbps
IB IL 24 DO 8-2MBD-PAC
2861687
1
Terminal with eight digital outputs;
complete with accessories (connectors not consecutively numbered and labeling fields);
transmission speed of 2 Mbps
IB IL 24 DO 8-2MBD-PAC/SN
2878227
1
Terminal with eight digital outputs; without accessories;
transmission speed of 2 Mbps
IB IL 24 DO 8-2MBD
2819037
1
One of the listed connectors is needed for the complete fitting of the IB IL 24 DO 8 and IB IL 24 DO 8-2MBD terminals.
Accessories
Description
Type
Order No.
Pcs./Pkt.
Connector with eight spring-cage connections (green, w/o color print)
IB IL SCN-8
2726337
10
Connector with eight spring-cage connections (green, with color print)
IB IL SCN-8-CP
2727608
10
Connector set with 32 spring-cage connections (green, w/o color print)
IB IL DI/DO 8-PLSET
2860950
1
Connector set with 32 spring-cage connections (green, with color print)
IB IL DI/DO 8-PLSET/CP
2860963
1
Documentation
Description
Type
Order No.
Pcs./Pkt.
"Configuring and installing the INTERBUS Inline product range" user manual
IB IL SYS PRO UM E
2743048
1
"Automation terminals of the Inline product range" user manual
IL SYS INST UM E
2698737
1
"INTERBUS addressing" data sheet
DB GB IBS SYS ADDRESS
–
–
"Safety-related segment circuit" application note
AH EN IL SAFE
–
–
5558_en_08
PHOENIX CONTACT
2
IB IL 24 DO 8 ...
3
Technical data
General data
Housing dimensions (width x height x depth)
48.8 mm x 119.8 mm x 71.5 mm
Weight
130 g (without connectors)
Operating mode
Process data mode with 1 byte
Connection method for actuators
2, 3, and 4-wire technology
Permissible temperature (operation)
-25°C to +55°C
Permissible temperature (storage/transport)
-25°C to +85°C
Permissible humidity (operation)
75% on average, 85% occasionally
Permissible humidity (operation/storage/transport)
10% to 95% according to DIN EN 61131-2
Permissible air pressure (operation/storage/transport)
70 kPa to 106 kPa (up to 3000 m above sea level)
Degree of protection
IP20 according to IEC 60529
Protection class
Class 3, according to EN 61131-2, IEC 61131-2
Connection data for connectors
Connection method
Spring-cage terminals
Conductor cross-section
0.08 mm2 to 1.5 mm2 (solid or stranded), 28 - 16 AWG
Interface
Local bus
Via data routing
Transmission speed
IB IL 24 DO 8
500 kbps
IB IL 24 DO 8-PAC
500 kbps
IB IL 24 DO 8-PAC/SN
500 kbps
IB IL DO 8-2MBD
2 Mbps
IB IL 24 DO 8-2MBD-PAC
2 Mbps
IB IL 24 DO 8-2MBD-PAC/SN
2 Mbps
Supply of the module electronics and I/O through the bus terminal/power terminal
Connection method
Via potential routing
Power consumption
500 kbps
2 Mbps
Communications power
7.5 V
7.5 V
Current consumption from the local bus
60 mA, maximum
85 mA, maximum
Power consumption from the local bus
0.45 W, maximum
0.64 W, maximum
Segment supply voltage US
24 V DC (nominal value)
24 V DC (nominal value)
Nominal current consumption at Us
4 A (8 x 0.5 A), maximum
4 A (8 x 0.5 A), maximum
Digital outputs
Number
8
Nominal output voltage UOUT
24 V DC
Differential voltage for Inom
≤1V
Nominal current Inom per channel
0.5 A
Tolerance of the nominal current
+10%
Total current
4A
Protection
Short circuit; overload
Channels are thermally coupled in groups of four, i.e., an error in one channel can affect the other channels.
Nominal load
Ohmic
48 Ω / 12 W
Lamp
12 W
Inductive
12 VA (1.2 H, 50 Ω)
5558_en_08
PHOENIX CONTACT
3
IB IL 24 DO 8 ...
Digital outputs (continued)
Signal delay upon power up of:
Nominal ohmic load
100 µs, typical
Nominal lamp load
100 ms, typical (with switching frequencies up to 8Hz; above this frequency
the lamp load responds like an ohmic load)
Nominal inductive load
100 ms, typical (1.2 H, 50 Ω)
Signal delay upon power down of:
Nominal ohmic load
1 ms, typical
Nominal lamp load
1 ms, typical
Nominal inductive load
50 ms, typical (1.2 H, 50 Ω)
Switching frequency with:
Nominal ohmic load
300 Hz, maximum
This switching frequency is limited by the selected data rate, the number of bus devices, the bus structure, the software and the control or
computer system used.
Nominal lamp load
300 Hz, maximum
This switching frequency is limited by the selected data rate, the number of bus devices, the bus structure, the software and the control or
computer system used.
0.5 Hz, maximum (1.2 H, 48 Ω)
Nominal inductive load
Overload response:
Auto restart
Response time with ohmic overload (12 Ω)
3 s, approximately
Restart frequency with ohmic overload
400 Hz, approximately
Restart frequency with lamp overload
400 Hz, approximately
Response with inductive overload
Output may be damaged
Response time in the event of a short circuit
400 ms, approximately
Reverse voltage protection against short pulses
Protected against reverse voltages
Resistance to permanently applied reverse voltages
Up to 2 A DC
Resistance to polarity reversal of the supply voltage
Protective elements in the bus terminal or power terminal
Resistance to permanently applied surge voltage
No
Validity of output data after connecting the 24 V voltage supply (power up)
5 ms, typical
Response upon power down
The output follows the supply voltage without delay.
Limitation of the voltage induced on circuit interruption
-15 V ≤ Udemag ≤ -46 V (Udemag = demagnetization voltage)
Single maximum energy in free running
400 mJ, maximum
Protective circuit type
Integrated 45 V Zener diode in the output chip
Overcurrent shutdown
0.7 A, minimum
Output current when switched off
300 µA, maximum
Output voltage when switched off
2 V, maximum
Output current with ground connection interrupt
25 mA, maximum
Switching power with ground connection interrupt
100 mW at 1 kΩ load resistance, typical
Inrush current with lamp load
1.5 A for 20 ms, maximum
Output characteristic curve when switched on (typical)
Output current (A)
5558_en_08
Differential output voltage (V)
0
0
0.1
0.04
0.2
0.08
0.3
0.12
0.4
0.16
0.5
0.20
PHOENIX CONTACT
4
IB IL 24 DO 8 ...
Power dissipation
Formula to calculate the power dissipation of the electronics
500 kbps
8
PEL = 0.19 W + S (0.10 W + ILn2 x 0.40 W)
n=1
2 Mbps
P
Where:
PEL
n
ILn
E L
= 0 .4 6 W
+ S
8
n = 1
(0 .1 0 W
+ IL
n
2
x 0 .4 0 W )
Total power dissipation in the terminal
Index of the number of set outputs n = 1 to 8
load current of output n
Power dissipation of the housing PHOU
2.7 W, maximum
(within the permissible operating temperature)
Limitation of simultaneity, derating
Derating
No limitation of simultaneity, no derating
Protective equipment
Overload/short circuit in the segment circuit
Electronic; with two 4-channel drivers
Surge voltage
Protective elements of the power terminal
Polarity reversal of the supply voltage
Protective elements of the power terminal
Protection up to 33 V DC
The supply voltage must be protected. The power supply unit should be able
to supply four times (400%) the nominal current of the fuse.
Reverse voltage
Protected against reverse voltages up to 2 A DC
Electrical isolation/isolation of the voltage areas
To provide electrical isolation between the logic level and the I/O area it is necessary to supply the station bus coupler and the digital output
terminal described here via the bus coupler or a power terminal from separate power supply units. Interconnection of the power supply units
in the 24 V area is not permitted. (See also user manual.)
Common potentials
The 24 V main voltage, 24 V segment voltage, and GND have the same potential. FE is a separate potential area.
Separate potentials in the system consisting of bus terminal/power terminal and I/O terminal
Test distance
Test voltage
5 V supply incoming remote bus/7.5 V supply (bus logic)
500 V AC, 50 Hz, 1 min.
5 V supply outgoing remote bus/7.5 V supply (bus logic)
500 V AC, 50 Hz, 1 min.
7.5 V supply (bus logic) / 24 V supply (I/O)
500 V AC, 50 Hz, 1 min.
24 V supply (I/O) / functional earth ground
500 V AC, 50 Hz, 1 min.
Error messages to the higher-level control or computer system
Short circuit/overload of an output
Yes
An error message is generated when an output is shorted and switched on. In addition, the diagnostic LED (D) flashes on the terminal at 2Hz
(medium) under these conditions.
Operating voltage out of range
No
Approvals
For the latest approvals, please visit www.phoenixcontact.net/catalog.
5558_en_08
PHOENIX CONTACT
5
IB IL 24 DO 8 ...
4
Internal basic circuit diagram
L o c a l b u s
O P C
U
L
4
2
+ 2 4 V (U
+ 2 4 V (U
4
2
2
4
4
2
2
2
2
)
S
M
2
)
5 5 5 8 C 0 0 3
Figure 1
Internal wiring of the terminal points
Key:
Protocol chip
(bus logic including voltage conditioning)
OPC
LED
Optocoupler
Transistor
Digital output
Electrically isolated area
Other symbols used are explained in the
IL SYS INST UM E user manual.
5558_en_08
PHOENIX CONTACT
6
IB IL 24 DO 8 ...
5
Local diagnostic and status indicators and terminal point assignment
5.1
Local diagnostic and status indicators
5.3
Terminal point assignment for each connector
A
B
4x
1
x
D
1
2
D O
1
1
2
1
2
2
x
1.1
1
1
1.2
2
2
1.3
8
2
1.4
3
3
4
4
1
x
2.1
1.1
1
2.2
1.2
2
2.3
1.3
2.4
1.4
2
1
1.1 2.1
11
1.2 2.2
3
2
1
2
x
11
11
1
22
22
2
3.3 4.3 5.3 6.3 7.3 8.3
33
1.4 2.4
4
1
3.2 4.2 5.2 6.2 7.2 8.2
22
1.3 2.3
2
3.1 4.1 5.1 6.1 7.1 8.1
33
33
3
3.4 4.4 5.4 6.4 7.4 8.4
44
44
44
4
8.1
8.2
8.3
8.4
5558A010
Figure 3
5 5 5 8 C 0 0 2
Figure 2
A
–
Local diagnostic and status indicators
–
Des.
D
1, 2
Color Meaning
B
–
Green Diagnostics
Yellow Status indicators for the outputs
–
5.2
Function identification
Pink
Terminal point numbering: individual connectors (A) and connector sets (B)
Using the IB IL 24 DO 8-PAC/SN or
IB IL 24 DO 8-2MBD-PAC/SN
with the supplied connectors
Using individual connectors
(IB IL SCN-8 or IB IL SCN-8-CP)
Using the IB IL 24 DO 8-PAC or
IB IL 24 DO 8-2MBD-PAC
with the original connector set
Using a connector set
(IB IL DI/DO 8-PLSET or
IB IL DI/DO 8-PLSET/CP)
2 Mbps: white stripe in the vicinity of the D LED
Terminal
point
Assignment
x.1
Signal output (OUT)
x.2
Segment voltage US
for 4-wire termination
Measuring points for the supply voltage
5558_en_08
x.3
Ground contact (GND)
for 2, 3, and 4-wire termination
x.4
FE connection
for 3 and 4-wire termination
PHOENIX CONTACT
7
IB IL 24 DO 8 ...
6
Connection example
7
When connecting the actuators observe the assignment of the terminal points to the process
data (see page 9).
Notes on using the terminals within
a safety-related segment circuit
The terminals of the following hardware version and later
(listed below) are approved for use within a safety-related
segment circuit.
Order No.
1
2
D
1
1
2
D O
4
3
1
2
2861289
2862945
2726269
2861687
2878227
2819037
1
2
Order designation
2
IB IL 24 DO 8-PAC
IB IL 24 DO 8-PAC/SN
IB IL 24 DO 8
IB IL 24 DO 8-2MBD-PAC
IB IL 24 DO 8-2MBD-PAC/SN
IB IL DO 8-2MBD
Hardware
version
05
07
05
04
04
04
8
1
2
1
2
1
2
1
The hardware version is marked on the side of the
housing of every terminal (1 in Figure 5).
2
1
1 1
1 1
1 1
1
2
2 2
2 2
2 2
2
3
3 3
3 3
3 3
3
1
IB IL 2 4 D O 8
O rd e r-N o .: 2 7 2 6 2 6 9
M o d u le - ID : X X
4
4 4
4 4
4 4
H W /S W
0 5 /-
4
IN T E R B U S
O U T
O U T
+ 2 4 V
5 5 5 8 A 0 0 8
B
A
5 5 5 8 2 0 0 4
Figure 4
A
B
Typical connection of actuators
4-wire termination
3-wire termination
Figure 5
Labeling on an Inline terminal
The instructions in the current documentation for
the safety terminal used and from the
AH EN IL SAFE application note must be observed to ensure that operation of the safety-related segment circuit is not adversely affected.
The latest documentation can be downloaded at
www.phoenixcontact.net/catalog.
The numbers above the module illustration identify the connector slots.
5558_en_08
PHOENIX CONTACT
8
IB IL 24 DO 8 ...
8
8.1
Programming data/
configuration data
Local bus (INTERBUS)
ID code
BDhex (189dec)
Length code
81hex
Process data channel
8 bits
Input address area
0 bytes
Output address area
1 byte
Parameter channel (PCP)
0 bytes
Register length (bus)
1 byte
8.2
Assignment of the terminal points to OUT process data
The following table applies to the IB IL 24 DO 8-PAC and
IB IL 24 DO 8-2MBD-PAC terminals with the original connector set and when using the IB IL DI/DO 8-PLSET and IB
IL DI/DO 8-PLSET/CP connector sets (see also Figure 3 on
page 7, detail B).
(Byte.bit) Byte
view
Bit
Assignment
Process data
For the assignment of the illustrated (byte.bit)
view to your INTERBUS control or computer system, please refer to the
DB GB IBS SYS ADDRESS data sheet.
Slot
6
5
4
4
3
3
2
1
2
0
1
Terminal
8.1 7.1 6.1 5.1 4.1 3.1 2.1 1.1
point (signal)
Terminal point 8.2 7.2 6.2 5.2 4.2 3.2 2.2 1.2
(+24 V)
Other bus systems
Terminal point 8.3 7.3 6.3 5.3 4.3 3.3 2.3 1.3
(GND)
For the programming data/configuration data of
other bus systems, please refer to the corresponding electronic device data sheet (GSD,
EDS).
9
Byte 0
7
Terminal point 8.4 7.4 6.4 5.4 4.4 3.4 2.4 1.4
(FE)
Status in- Slot
dicator
LED
4
2
3
1
2
2
1
2
1
1
2
1
The following table applies to the IB IL 24 DO 8-PAC/SN
and IB IL 24 DO 8-2MBD-PAC/SN terminals with the original connector set and when using the IB IL SCN-8 or IB IL
SCN-8-CP connectors (see also Figure 3 on page 7,
detail A).
(Byte.bit) Byte
view
Bit
Assignment
Byte 0
7
Slot
6
5
4
4
3
3
2
1
2
0
1
Terminal
2.1 1.1 2.1 1.1 2.1 1.1 2.1 1.1
point (signal)
Terminal point 2.2 1.2 2.2 1.2 2.2 1.2 2.2 1.2
(+24 V)
Terminal point 2.3 1.3 2.3 1.3 2.3 1.3 2.3 1.3
(GND)
Terminal point 2.4 1.4 2.4 1.4 2.4 1.4 2.4 1.4
(FE)
Status in- Slot
dicator
LED
5558_en_08
4
2
3
1
2
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00
PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300
www.phoenixcontact.com
2
1
2
1
1
2
1
9