2864053

2864053

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MCR 3-WAY ISOLATION AMPLIFIER

  • 数据手册
  • 价格&库存
2864053 数据手册
Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. MCR 3-way signal conditioner, with configurable input/output, for electrical isolation and conversion of analog signals up to 30 V with screw connection, order configuration. Replacement part: 2902036 MINI MCR-2-UI-UI-C. Product Description The 6.2 mm wide configurable 3-way isolating amplifier MINI MCR-SL-U-UI-... is used for electrical isolation, conversion, amplification and filtering of standard signals. The signals 0...24 V and 0...30 V can be processed on the input side. The analog signals 0...20 mA, 4...20 mA, 0...10 V, 2...10 V, 0...5 V or 1..5 V are available electrically isolated on the output side. The DIP switches, which can be accessed on the side of the housing, can be used to configure the input and output signal ranges. Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector. Your advantages • Power supply possible via the foot element (TBUS) • Low power consumption • 3-way isolation • Up to 12 signal combinations can be configured using DIP switches • 30 V DC signals to create standard analog signals • Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of 24 V or Commercial Data Item number 2864053 Packing unit 1 pc Minimum order quantity 1 pc Note Made to Order (non-returnable) Sales Key C01 Product Key CK1211 Catalog Page Page 96 (C-7-2015) Weight per Piece (including packing) 88.1 g Weight per Piece (excluding packing) 66.2 g Customs tariff number 85437090 Country of origin DE Oct 27, 2022, 7:34 AM Page 1 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Technical Data Product properties Product type Signal conditioner No. of channels 1 Insulation characteristics Overvoltage category II Pollution degree 2 Electrical properties No. of channels 1 Rated insulation voltage 50 V AC/DC Electrical isolation Basic insulation in accordance with EN 61010 Electrical isolation between input and output yes Limit frequency (3 dB) approx. 100 Hz Test voltage, input/output/supply 1.5 kV AC (50 Hz, 60 s) Protective circuit Transient protection Step response (10-90%) 3.5 ms Maximum temperature coefficient < 0.01 %/K Temperature coefficient, typical < 0.002 %/K Maximum transmission error < 0.1 % (of final value) < 0.4 % (Without adjustment) Supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) Max. current consumption < 19 mA (at 24 V DC incl. load) Power consumption < 450 mW Input data Signal: Number of inputs 1 Configurable/programmable Yes, preconfigured Voltage input signal 0 V ... 24 V 0 V ... 30 V Max. voltage input signal 50 V DC Input resistance of voltage input approx. 125 kΩ (0 ... 24 V) approx. 155 kΩ (0 ... 30 V) Output data Oct 27, 2022, 7:34 AM Page 2 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Signal: Number of outputs 1 Configurable/programmable Yes, preconfigured Voltage output signal 0 V ... 10 V 0 V ... 5 V 1 V ... 5 V 2 V ... 10 V Max. voltage output signal ≤ 12.5 V Non-load voltage ≤ 12.5 V Current output signal 0 mA ... 20 mA 4 mA ... 20 mA Max. current output signal 28 mA Short-circuit current ≤ 22 mA Load/output load voltage output > 10 kΩ Load/output load current output < 500 Ω (at 20 mA) Ripple < 20 mVPP (at 500 Ω) < 20 mVPP (at 10 kΩ) Connection data Connection method Screw connection Stripping length 12 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 26 ... 12 Dimensions Dimensional drawing Width 6.2 mm Height 93.1 mm Depth 102.5 mm Material specifications Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 Housing material PBT Oct 27, 2022, 7:34 AM Page 3 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Approval data CE Certificate CE-compliant ATEX Identification II 3 G Ex nA IIC T4 Gc X UL, USA / Canada Identification UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL Identification GL EMC 2 D EMC data Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Note When being exposed to interference, there may be minimal deviations. Electrostatic discharge Standards/regulations EN 61000-4-2 Electrostatic discharge Comments Safety measures must be taken to prevent electrostatic discharge. Electromagnetic HF field Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 5% Fast transients (burst) Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 5% Surge current load (surge) Standards/regulations EN 61000-4-5 Oct 27, 2022, 7:34 AM Page 4 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Surge current load (surge) Comments Criterion B Conducted interference Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 5% Standards and regulations Electrical isolation Basic insulation in accordance with EN 61010 Mounting Mounting type DIN rail mounting Assembly instructions The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715. Mounting position any Oct 27, 2022, 7:34 AM Page 5 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Drawings Dimensional drawing 6,2 102,5 93,1 Oct 27, 2022, 7:34 AM Page 6 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Block diagram IN Sensor / Field OUT U US 4-wire GND 1 OUT + 2 2 – + – 4 3 1 IN U GND 1 +24V OUT U, I active GND 2 PLC / DCS 5 6 +24V GND 3 5 + GND 3 passive 6 – 7 + 8 – +24V GND 3 Oct 27, 2022, 7:34 AM Page 7 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Application drawing 0...24V IN U OUT GND1 GND2 1 UPS 2 3 4 UB+ GND3 0...10V 5 6 UB + GND3 MINI MCR-SL-U-UI Controller 7 8 24V Mains voltage Signal conversion to uninterruptible power supply (UPS) Oct 27, 2022, 7:34 AM Page 8 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Classifications ECLASS ECLASS-9.0 27210120 ECLASS-10.0.1 27210120 ECLASS-11.0 27210120 ETIM ETIM 7.0 EC002653 Oct 27, 2022, 7:34 AM Page 9 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Oct 27, 2022, 7:34 AM Page 10 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Accessories DIN rail bus connectors DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 https://www.phoenixcontact.com/us/products/2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Goldplated contacts, 5-pos. Power terminal block Power terminal block - MINI MCR-SL-PTB - 2864134 https://www.phoenixcontact.com/us/products/2864134 MCR power terminal block for supplying several MINI Analog modules via the DIN rail connector, with screw connection, maximum current consumption of up to 2 A Oct 27, 2022, 7:34 AM Page 11 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Power supply unit Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 https://www.phoenixcontact.com/us/products/2866983 Please use the following item in new systems: 2904614 Primary-switched MINI POWER power supply for DIN rail mounting, input: 1phase, output: 24 V DC/1.5 A Marking label Marking label - MINI MCR-DKL-LABEL - 2810272 https://www.phoenixcontact.com/us/products/2810272 Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL Oct 27, 2022, 7:34 AM Page 12 (13) Signal conditioner - MINI MCR-SL-U-UI 2864053 https://www.phoenixcontact.com/us/products/2864053 Transparent cover Transparent cover - MINI MCR DKL - 2308111 https://www.phoenixcontact.com/us/products/2308111 Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm Phoenix Contact 2022 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Oct 27, 2022, 7:34 AM Page 13 (13)
2864053 价格&库存

很抱歉,暂时无法提供与“2864053”相匹配的价格&库存,您可以联系我们找货

免费人工找货