2864163

2864163

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    3-WAY ISOLATING AMP 4-20MA

  • 数据手册
  • 价格&库存
2864163 数据手册
https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR 3-way isolating amplifier, I/O can be configured via DIP switches, for the electrical isolation of analog signals, with spring-cage connection, standard configuration The illustration shows the versions with screw connection Product Features ■ ■ ■ ■ ■ Power supply possible via the foot element (TBUS) Up to 36 signal combinations can be configured using DIP switches Low power consumption Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of standard analog signals 3-way isolation Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 64.4 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm 03/15/2016   Page 1 / 7 https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Technical data Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Degree of protection IP20 Input data Number of inputs 1 Configurable/programmable Yes, unconfigured Voltage input signal 0 V ... 10 V 0 V ... 5 V 1 V ... 5 V 2 V ... 10 V Current input signal 0 mA ... 20 mA 4 mA ... 20 mA Max. input voltage 30 V Max. input current 50 mA Input resistance of voltage input approx. 100 kΩ Input resistance current input approx. 50 Ω Output data Number of outputs 1 Configurable/programmable Yes, unconfigured Voltage output signal 0 V ... 10 V 0 V ... 5 V 1 V ... 5 V 2 V ... 10 V Current output signal 0 mA ... 20 mA (please indicate if different setting when ordering) 4 mA ... 20 mA Max. output voltage approx. 12.5 V Max. output current 28 mA Short-circuit current approx. 22 mA Load/output load voltage output ≥ 10 kΩ Load/output load current output < 500 Ω (at 20 mA) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Max. current consumption < 19 mA (Current output, at 24 V DC incl. load) < 9 mA (Voltage output, at 24 V DC incl. load) 03/15/2016   Page 2 / 7 https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Technical data Power supply Power consumption < 450 mW (Current output) < 200 mW (Voltage output) Connection data Connection method Spring-cage connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 8 mm General No. of channels 1 Maximum transmission error ≤ 0.1 % (of final value) < 0.4 % (Without adjustment) Maximum temperature coefficient < 0.01 %/K Temperature coefficient, typical < 0.002 %/K Limit frequency (3 dB) approx. 100 Hz Step response (10-90%) approx. 3.2 ms Protective circuit Transient protection Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized 03/15/2016   Page 3 / 7 https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Technical data General Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 5% Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 5% Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 5% Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Connection in acc. with standard CUL Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 03/15/2016   Page 4 / 7 https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Classifications eCl@ss eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 ETIM ETIM 2.0 EC001485 ETIM 3.0 EC001485 ETIM 4.0 EC001485 ETIM 5.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / GL / EAC / cULus Recognized Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approvals submitted Approval details UL Recognized  03/15/2016   Page 5 / 7 https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Approvals cUL Recognized  GL  EAC  cULus Recognized  Drawings Block diagram Dimensional drawing 93,1 + 1 IN U,I OUT U,I 5 + 5 active 4-wire GND 2 – 2 + 3 – 4 GND 1 +24V passive GND 2 6 – +24V GND 3 6,2 PLC / DCS 6 7 + GND 3 8 – 102,5 OUT 1 U,I US OUT IN Sensor / Field +24V GND 3 Zone 2 Div. 2 03/15/2016   Page 6 / 7 https://www.phoenixcontact.com/us/products/2864163 Signal conditioner - MINI MCR-SL-UI-UI-SP-NC - 2864163 Application drawing 24V Level gauge 0...10V 0...20mA 1 IN OUT 5 2 GND1 GND2 6 Control system 3 UB+ UB+ 7 4 GND3 GND3 8 MINI MCR-SL-UI-UI 24V Mains voltage Level measurement Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 03/15/2016   Page 7 / 7
2864163 价格&库存

很抱歉,暂时无法提供与“2864163”相匹配的价格&库存,您可以联系我们找货

免费人工找货