2864189

2864189

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    4-WAY SIGNAL DUPLICATOR

  • 数据手册
  • 价格&库存
2864189 数据手册
https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR 4-way signal duplicator for electrical isolation and doubling of analog signals with spring-cage connection, standard configuration Product Description The 6.2 mm wide configurable 4-way isolating amplifier MINI MCR-SL-UI-2I-... is used for electrical isolation, conversion, amplification and filtering of standard signals. On the input side, the analog standard signals 0...20 mA, 4...20 mA, 0...10 V or 1...5V can be selected, on the output side there are two current outputs that can be set independently of one another with a 0...20 mA-, or 4...20mA signal, electrically isolated (4-way isolation). The DIP switches, which can be accessed on the side of the housing, can be used to configure the input and output signal ranges. Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector. Why buy this product  Power supply possible via the foot element (TBUS)  Duplication of a standard analog signal on two current outputs  Highly-compact isolating amplifier for electrical isolation, conversion, amplification, filtering, and duplication of standard analog signals  4-way isolation  Up to 8 signal combinations can be configured using DIP switches Key Commercial Data Packing unit 1 STK GTIN GTIN 4017918974817 Weight per Piece (excluding packing) 62.900 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area 04/19/2018   Page 1 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Technical data Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 60 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Input data Number of inputs 1 Configurable/programmable Yes, unconfigured Voltage input signal 0 V ... 10 V (please indicate if different setting when ordering) 1 V ... 5 V Current input signal 0 mA ... 20 mA 4 mA ... 20 mA max. input voltage 30 V Max. input current 50 mA Input resistance of voltage input approx. 100 kΩ Input resistance current input approx. 50 Ω Output data Number of outputs 2 Configurable/programmable Yes, unconfigured Current output signal 2x 0 mA ... 20 mA 2x 4 mA ... 20 mA Max. output current approx. 22 mA Load/output load current output ≤ 250 Ω (at 20 mA) Ripple < 20 mVPP (at 250 Ω) Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Max. current consumption < 30 mA (at 24 V DC incl. load) Power consumption < 600 mW Connection data Connection method Spring-cage connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 24 Conductor cross section AWG max. 12 04/19/2018   Page 2 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Technical data Connection data Conductor cross section flexible min. 0.2 mm² Conductor cross section flexible max. 2.5 mm² Stripping length 8 mm General No. of channels 2 Maximum transmission error ≤ 0.2 % (of final value) Transmission error, typical < 0.1 % Maximum temperature coefficient < 0.01 %/K Temperature coefficient, typical < 0.004 %/K Limit frequency (3 dB) approx. 35 Hz Protective circuit Transient protection Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 5% Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 5% 04/19/2018   Page 3 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Technical data EMC data Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 5% Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 2 HL 1 - HL 2 HL 1 - HL 2 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 04/19/2018   Page 4 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Block diagram OUT 1 U,I US OUT IN Sensor / Field + 1 IN U,I PLC / DCS OUT 1 I 5 + 5 active 4-wire GND 2 – 2 + 3 GND 3 OUT 2 I passive GND 1 6 – +24V 6 7 + active – 4 GND 2 GND 4 8 – 3 +24V GND 4 passive 4 Zone 2 Div. 2 Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / GL / EAC / cULus Recognized 04/19/2018   Page 5 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Approvals Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approval details UL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 cUL Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 238705 GL    http://exchange.dnv.com/tari/  24917-05 HH EAC      EAC-Zulassung cULus Recognized    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm   Accessories Accessories DIN rail connector DIN rail bus connectors - ME 6,2 TBUS-2 1,5/5-ST-3,81 GN - 2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos.     Marking material 04/19/2018   Page 6 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Accessories Transparent cover - MINI MCR DKL - 2308111 Fold up transparent cover for MINI MCR modules with additional labeling option using insert strips and flat Zack marker strip 6.2 mm     Marking label - MINI MCR-DKL-LABEL - 2810272 Label for extended marking of MINI MCR modules in connection with the MINI MCR-DKL     Power module Power terminal block - MINI MCR-SL-PTB - 2864134 MCR power terminal block for supplying several MINI Analog modules via the DIN rail connector, with screw connection, maximum current consumption of up to 2 A     Power terminal block - MINI MCR-SL-PTB-SP - 2864147 MCR power terminal block for supplying several MINI Analog modules via the DIN rail connector, with spring-cage connection, maximum current consumption of up to 2 A     Power supply Power supply unit - MINI-SYS-PS-100-240AC/24DC/1.5 - 2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A     04/19/2018   Page 7 / 8 https://www.phoenixcontact.com/gb/products/2864189 Signal duplicator - MINI MCR-SL-UI-2I-SP-NC - 2864189 Accessories Power supply unit - MINI-PS-100-240AC/24DC/1.5/EX - 2866653 Primary-switched power supply MINI POWER for DIN rail mounting, input: 1-phase, output: 24 V DC/1,5 A, for the potentially explosive area     Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com 04/19/2018   Page 8 / 8
2864189 价格&库存

很抱歉,暂时无法提供与“2864189”相匹配的价格&库存,您可以联系我们找货

免费人工找货