2864202

2864202

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    TEMP TRANSDUCER DIN RAIL

  • 数据手册
  • 价格&库存
2864202 数据手册
Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Please be informed that the data shown in this PDF document is generated from our Online Catalog. Please find the complete data in the user documentation. Our General Terms of Use for Downloads are valid. MCR temperature transducer, configurable, for Pt 100 temperature sensors, with spring-cage connection, not configured. Replacement part: 2902052 MINI MCR-2-RTD-UI-PT. Your advantages • Power supply possible via the foot element (TBUS) • Optimized temperature measuring range of -50°C to +200°C for increased accuracy • For 2-, 3-, 4-conductor Pt 100 sensors in accordance with IEC 60751 • Error indication via diagnostic LED and analog signal • Input and output signals can be configured via DIP switches • Highly-compact temperature transducer for electrical isolation, conversion, amplification, and filtering of • Pt 100 signals to create standard signals • 3-way isolation Commercial Data Item number 2864202 Packing unit 1 pc Minimum order quantity 1 pc Note Made to Order (non-returnable) Sales Key C01 Product Key CK1221 Catalog Page Page 104 (C-7-2015) GTIN 4046356046466 Weight per Piece (including packing) 91.7 g Weight per Piece (excluding packing) 59.9 g Customs tariff number 85437090 Country of origin DE Oct 27, 2022, 7:33 AM Page 1 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Technical Data Product properties Product type Temperature transmitter Insulation characteristics Overvoltage category II Pollution degree 2 Electrical properties Rated insulation voltage 50 V AC/DC Electrical isolation Basic insulation in accordance with EN 61010 Maximum power dissipation for nominal condition 235.5 mW Test voltage, input/output/supply 1.5 kV AC (50 Hz, 60 s) Protective circuit Transient protection Step response (0–99%) < 200 ms Maximum temperature coefficient < 0.02 %/K Transmission error in the set measuring range ((50 K / Δ Temp)+ 0.05)% Transmission error in the full measuring range ≤ 0,25 % Supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) Max. current consumption < 21 mA (at 24 V DC) Power consumption < 500 mW Input data Signal: Number of inputs 1 Input signal Temperature Measurement Sensor types (RTD) that can be used Pt 100 (IEC 60751/EN 60751) Temperature measuring range -50 °C ... 200 °C Temperature measuring range min. 50 K Sensor type: -50 °C ... 200 °C (configurable) Sensor input current 1 mA (constant) Max. permissible overall conductor resistance 10 Ω (Per cable) Connection technology 2-, 3-, 4-conductor Output data Oct 27, 2022, 7:33 AM Page 2 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Signal: Number of outputs 1 Configurable/programmable Yes Voltage output signal 0 V ... 10 V 10 V ... 0 V 0 V ... 5 V 1 V ... 5 V Max. voltage output signal approx. 12.5 V Non-load voltage approx. 12.5 V Current output signal 0 mA ... 20 mA 4 mA ... 20 mA 20 mA ... 0 mA 20 mA ... 4 mA Max. current output signal 23 mA Short-circuit current approx. 10 mA Load/output load voltage output > 10 kΩ Load/output load current output < 500 Ω (at 20 mA) Ripple < 20 mVPP (at 500 Ω) < 20 mVPP (at 10 kΩ) Connection data Connection method Spring-cage connection Stripping length 8 mm Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 12 Dimensions Dimensional drawing Width 6.2 mm Height 93.1 mm Depth 102.5 mm Material specifications Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 Oct 27, 2022, 7:33 AM Page 3 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Housing material PBT Environmental and real-life conditions Ambient conditions Degree of protection IP20 Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Approval data CE Certificate CE-compliant ATEX Identification II 3 G Ex nA IIC T4 Gc X UL, USA / Canada Identification UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL Identification GL EMC 2 D EMC data Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 Note When being exposed to interference, there may be minimal deviations. Electrostatic discharge Standards/regulations EN 61000-4-2 Electrostatic discharge Comments Safety measures must be taken to prevent electrostatic discharge. Electromagnetic HF field Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 10 % Fast transients (burst) Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 10 % Oct 27, 2022, 7:33 AM Page 4 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Surge current load (surge) Standards/regulations EN 61000-4-5 Surge current load (surge) Comments Criterion B Conducted interference Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 10 % Standards and regulations Electrical isolation Basic insulation in accordance with EN 61010 Mounting Mounting type DIN rail mounting Mounting position any Oct 27, 2022, 7:33 AM Page 5 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Drawings Dimensional drawing 6,2 102,5 93,1 Oct 27, 2022, 7:33 AM Page 6 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Block diagram IN Sensor / Field PT 100 ϑ ϑ OUT 1 ϑ 1 2 2 3 3 4 OUT U,I active GND 1 PLC / DCS 5 + 6 – +24V 4 GND 2 5 passive 6 7 + 8 – +24V GND 2 Oct 27, 2022, 7:33 AM Page 7 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Classifications ECLASS ECLASS-9.0 27210129 ECLASS-10.0.1 27210129 ECLASS-11.0 27210129 ETIM ETIM 7.0 EC002919 Oct 27, 2022, 7:33 AM Page 8 (9) Temperature measuring transducer - MINI MCR-SLPT100-UI-200-SP-NC 2864202 https://www.phoenixcontact.com/us/products/2864202 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” Phoenix Contact 2022 © - all rights reserved https://www.phoenixcontact.com Phoenix Contact USA 586 Fulling Mill Road Middletown, PA 17057, United States (+717) 944-1300 info@phoenixcon.com Oct 27, 2022, 7:33 AM Page 9 (9)
2864202 价格&库存

很抱歉,暂时无法提供与“2864202”相匹配的价格&库存,您可以联系我们找货

免费人工找货