2864529

2864529

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    HEADMOUNTTEMPTRANSDUCER

  • 数据手册
  • 价格&库存
2864529 数据手册
Programmable Loop-Powered Temperature Measuring Transducer MCR-FL-HT-T-I 1. Brief Description – For resistance thermometers, thermocouples, and resistance and voltage sensors – For installation in Form B connection head POWER FL I Dimensional drawing for MCR-FL-HT-T-I 44 33 7 2 5 6 3 21 1 Universal PC programmable temperature measuring transducers convert temperature signals from resistance thermometers and thermocouples as well as sensors with linear mV characteristic curves to analog 4…20 mA signals. On the output side the temperature measuring transducers are operated in a 4…20 mA current loop, which simultaneously provides the module with the required power for signal conversion. To change the configuration data, use the MCR-PAC-T programming adapter (Order No. 28 64 59 0) and the Windows-compatible MCR-PI-CONF-WIN configuration software (Order No. 28 14 79 9). Customized measuring range settings and an extended setup can thus be implemented. Failure information in the event of sensor breaks or sensor short circuit can be set according to NE 43. This measuring transducer maintains a high level of accuracy throughout the entire ambient operating temperature range. The devices are supplied with the following default configuration: PT100 sensor, 0…100°C (32…212ºF) measuring range, 3-wire termination. 4 ϑ 5 Temperature – Can be freely programmed using the MCR-PI-CONF-WIN configuration software (Order No. 28 14 79 9) Headquarters: © Phoenix Contact GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany Phone +49 - 52 35 - 30 0 • Fax +49 - 52 35 - 34 12 00 • www.phoenixcontact.com Local contact: www.phoenixcontact.com/salesnetwork Programmable Loop-Powered Temperature Measuring Transducer - MCR-FL-HT-T-I 1.1. Input Signals Designation Resistance thermometer (RTD) -200 to +850˚C(-328 to +1562˚F) -200 to +250˚C(-328 to +482˚F) -200 to +250˚C(-328 to +482˚F) 10 K 10 K 10 K Ni100 Ni500 Ni1000 according to DIN 43760 -60 to +250˚C (-76 to +482˚F) -60 to +150˚C (-76 to +302˚F) -60 to +150˚C (-76 to +302˚F) 10 K 10 K 10 K Connection type: 2, 3 or 4-wire termination With 2-wire termination, the cable resistance can be compensated (0...20 Ω). With 3 and 4-wire termination, sensor cable resistance up to a maximum of 11 Ω per cable Sensor current ≤ 0.6 mA Resistance (Ω) 10...400 Ω 10...2000 Ω Designation Thermocouple (TC) Minimum Measuring Span Pt100 Pt500 Pt1000 according to IEC 751 • • • • Resistance sensor Measuring Range Limits B (PtRh30-PtRh6) C (W5Re-W26Re)1) D (W3Re-W25Re)1) E (NiCr-CuNi) J (Fe-CuNi) K (NiCr-Ni) L (Fe-CuNi)2) N (NiCrSi-NiSi) R (PtRh13-Pt) S (PtRh10-Pt) T (Cu-CuNi) U (Cu-CuNi)2) MoRe5-MoRe413) according to IEC 584 Part 1 10 Ω 100 Ω Measuring Range Limits 0 to +1820˚C (+32 to +3308˚F) 0 to +2320˚C (+32 to 4208˚F) 0 to +2495˚C (+32 to +4523˚F) -200 to +915˚C (-328 to +1679˚F) -200 to +1200˚C (-328 to 2192˚F) -270 to +1372˚C (-454 to +2501˚F) -200 to +900˚C (-328 to +1652˚F) -270 to +1300˚C (-454 to +2372˚F) 0 to +1768˚C (+32 to +3214˚F) -50 to +1768˚C (-58 to +3214˚F) -200 to +400˚C (-328 to +752˚F) -200 to +600˚C (-328 to +1112˚F) 0 to +2000˚C (+32 to +3632˚F) Minimum Measuring Span 500 K 500 K 500 K 50 K 50 K 50 K 50 K 50 K 500 K 500 K 50 K 50 K 500 K • Cold junction: internal (Pt100) or external (0...80°C [32…176ºF]) • Cold junction accuracy: ±1 K Voltage sensor (mV) 1) 2) 3) Millivolt sensor (mV) -10...100 mV According to ASTM E988 According to DIN 43710 No specification PHOENIX CONTACT page 2 of 7 5 mV Programmable Loop-Powered Temperature Measuring Transducer - MCR-FL-HT-T-I 2. Technical Data IN OUT 3 ϑ µC D 4 DC DC 1 OUT 1 D A 8 - 35 V DC 2 GND 1 5 6 MCR-FL-HT-T-I 8 mm (0.31 in.) Programmable loop-powered temperature measuring transducer M3 u solid [mm2] Connection data 0.2 - 1.75 flexible 0.2 - 1.75 AWG 24 - 16 Description Type Order No. MCR temperature measuring transducer, for resistance thermometers, thermocouples, and resistance and voltage sensors MCR-FL-HT-T-I 28 64 52 9 Pcs. Pkt. 1 Technical Data Input • PT100, PT500, PT1000 and Ni100, Ni500, Ni1000 resistance thermometers, in 2, 3 or 4-wire technology, minimum measuring span of 10 K • Thermocouple sensors (B, C, D, E, J, K, L, N, R, S, T, U); minimum measuring span of 50 K/500 K • Linear mV signals from -10 mV to +100 mV; minimum measuring span of 5 mV • Resistance sensor of 10 Ω to 400 Ω and 10 Ω to 2000 Ω; minimum measuring span of 10 Ω/100 Ω Output Output signal Maximum output signal Load Output signal in the event of open circuit/short circuit 1) Measuring range exceeded/not reached 4…20 mA/20…4 mA ≤ 25 mA (VSupply - 8 V)/0.025 A, maximum ≤ 3.6 mA/≥ 21.0 mA ≤ 20.5 mA/≥ 3.8 mA (linear increase/drop) PHOENIX CONTACT page 3 of 7 Programmable Loop-Powered Temperature Measuring Transducer - MCR-FL-HT-T-I General Data Supply voltage Maximum current consumption Resistance thermometer (RTD) Transmission error2) Thermocouple (TC)5) Resistance sensor (Ω) Voltage sensor (mV) Influence of the ambient temperature (temperature drift) 8…35 V DC < 3.5 mA 0.2 K or 0.08% (Pt100, Ni100), 0.5 K or 0.20% (Pt500, Ni500), 0.3 K or 0.12% (Pt1000, Ni1000) 0.5 K or 0.08% (K, J, T, E, L, U), typical, 1.0 K or 0.08% (N, C, D), typical, 2.0 K or 0.08% (S, B, R, MoRe5-MoRe41), typical ±0.1 Ω or 0.08% (10…400 Ω), ±1.5 Ω or 0.12% (10…2000 Ω), ±20 µV or 0.08% (-10…100 mV) • Resistance thermometer (RTD): Td = ± (15 ppm/K • maximum measuring range + 50 ppm/K • set measuring range) • ∆ϑ3) • Pt100 resistance thermometer: Td = ± (15 ppm/K • (measuring range final value + 200) + 50 ppm/K • set measuring range) • ∆ϑ3) • Thermocouple (TC): Td = ± (50 ppm/K • maximum measuring range + 50 ppm/K • set measuring range) • ∆ϑ3) Influence of the load4) Influence of the supply voltage4) Response time On delay Test voltage Ambient operating temperature range Storage temperature Climatic category Condensation Degree of protection Mounting location Mounting position Resistance to shock and vibration Configuration Electromagnetic compatibility • Noise emission and noise immunity Housing material Weight Input/output 3. c Conformance With EMC Directive 89/336/EEC ≤ ±0.02%/100 Ω ≤ ±0.01%/V deviation of 24 V
2864529 价格&库存

很抱歉,暂时无法提供与“2864529”相匹配的价格&库存,您可以联系我们找货

免费人工找货