https://www.phoenixcontact.com/us/products/2864684 Signal conditioner - MINI MCR-SL-U-U - 2864684 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR 3-way isolating amplifier, for electrical isolation of analog signals, with screw connection, input signal: 0 ... 10 V/±10 V, output signal: 0 ... 10 V/±10 V Product Description The 6.2 mm wide standard signal 3-way isolating amplifier MINI MCR-SL-U-U(-SP) is used for electrical isolation, amplification and filtering of standard signals. On the input and output side, the analog standard signals 0...10 V or ±10 V are available, electrically isolated. Power (19.2 V DC to 30 V DC) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector. Product Features ■ ■ ■ ■ ■ ■ Power supply possible via the foot element (TBUS) Low power consumption Entry-level alternative to configurable signal conditioners Fixed signal combinations Highly-compact isolating amplifier for electrical isolation, conversion, amplification, and filtering of standard analog signals 3-way isolation Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 90.0 g Custom tariff number 85437090 Country of origin Germany Technical data Note Utilization restriction EMC: class A product, see manufacturer's declaration in the download area 04/12/2016   Page 1 / 6 https://www.phoenixcontact.com/us/products/2864684 Signal conditioner - MINI MCR-SL-U-U - 2864684 Technical data Dimensions Width 6.2 mm Height 93.1 mm Depth 102.5 mm Ambient conditions Ambient temperature (operation) -20 °C ... 65 °C Ambient temperature (storage/transport) -40 °C ... 85 °C Degree of protection IP20 Input data Number of inputs 1 Configurable/programmable no Voltage input signal 0 V ... 10 V -10 V ... 10 V Max. input voltage 30 V Input resistance of voltage input approx. 100 kΩ Output data Number of outputs 1 Configurable/programmable no Voltage output signal 0 V ... 10 V -10 V ... 10 V Max. output voltage 12.5 V Short-circuit current approx. 2 mA Load/output load voltage output ≥ 10 kΩ Power supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715)) Max. current consumption < 9 mA Power consumption < 200 mW (at 24 V DC) Connection data Connection method Screw connection Conductor cross section solid min. 0.2 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section AWG min. 26 Conductor cross section AWG max. 12 Conductor cross section flexible min. 0.2 mm² 04/12/2016   Page 2 / 6 https://www.phoenixcontact.com/us/products/2864684 Signal conditioner - MINI MCR-SL-U-U - 2864684 Technical data Connection data Conductor cross section flexible max. 2.5 mm² Stripping length 12 mm Screw thread M3 General No. of channels 1 Maximum transmission error ≤ 0.1 % (of final value) Maximum temperature coefficient < 0.01 %/K Temperature coefficient, typical < 0.002 %/K Limit frequency (3 dB) approx. 100 Hz Step response (10-90%) approx. 3.2 ms Protective circuit Transient protection Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 50 V AC/DC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Assembly instructions The T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715. Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D EMC data Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 Typical deviation from the measuring range final value 15 % Designation Fast transients (burst) Standards/regulations EN 61000-4-4 Typical deviation from the measuring range final value 15 % 04/12/2016   Page 3 / 6 https://www.phoenixcontact.com/us/products/2864684 Signal conditioner - MINI MCR-SL-U-U - 2864684 Technical data EMC data Designation Conducted interferences Standards/regulations EN 61000-4-6 Typical deviation from the measuring range final value 15 % Standards and Regulations Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC Noise emission EN 61000-6-4 Connection in acc. with standard CUL Designation Electromagnetic RF field Standards/regulations EN 61000-4-3 EN 61000-4-4 Designation Conducted interferences Standards/regulations EN 61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX  II 3 G Ex nA IIC T4 Gc X UL, USA / Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T5 GL GL EMC 2 D Classifications eCl@ss eCl@ss 4.0 27210120 eCl@ss 4.1 27210120 eCl@ss 5.0 27210120 eCl@ss 5.1 27210120 eCl@ss 6.0 27210120 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 2.0 EC001485 ETIM 3.0 EC001485 ETIM 4.0 EC001485 ETIM 5.0 EC002653 04/12/2016   Page 4 / 6 https://www.phoenixcontact.com/us/products/2864684 Signal conditioner - MINI MCR-SL-U-U - 2864684 Classifications UNSPSC UNSPSC 6.01 30211506 UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 Approvals Approvals Approvals UL Recognized / cUL Recognized / GL / EAC / cULus Recognized Ex Approvals UL Listed / cUL Listed / ATEX / cULus Listed Approvals submitted Approval details UL Recognized  cUL Recognized  GL  EAC  cULus Recognized  04/12/2016   Page 5 / 6 https://www.phoenixcontact.com/us/products/2864684 Signal conditioner - MINI MCR-SL-U-U - 2864684 Drawings Block diagram Dimensional drawing 93,1 1 + 1 IN U OUT U 5 + 5 active 4-wire GND 2 – 2 + 3 – 4 passive GND 2 GND 1 6 – +24V +24V GND 3 6,2 PLC / DCS 6 7 + GND 3 8 – 102,5 OUT U US OUT IN Sensor / Field +24V GND 3 Zone 2 Div. 2 Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/12/2016   Page 6 / 6
2864684
物料型号:MINI MCR-SL-U-U,产品编号为2864684。

器件简介:MINI MCR-SL-U-U是一款用于电气隔离、放大和滤波的标准信号三隔离放大器。它适用于6.2毫米宽的标准信号,可在输入和输出侧提供电气隔离的模拟标准信号0...10V或±10V。

引脚分配:文档中提供了一个块图,显示了输入(1+, 1-, GND)和输出(3+, 3-, GND)的引脚分配,以及电源(+24V)。

参数特性:提供了电气隔离、输入/输出信号范围、最大功耗、响应时间、温度系数、传输误差等详细参数。

功能详解:该器件具有电气隔离、信号转换、放大和滤波的功能,适用于标准模拟信号。

应用信息:适用于需要电气隔离和信号处理的工业自动化和控制系统。

封装信息:宽度为6.2毫米,高度为93.1毫米,深度为101.2毫米。材料为PBT,符合多种防火和环保标准。
2864684 价格&库存

很抱歉,暂时无法提供与“2864684”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2864684
  •  国内价格
  • 1+2338.85408

库存:9

2864684
  •  国内价格 香港价格
  • 1+3017.055381+389.95201

库存:0