MACX MCR-EX-SL-RPSS-2I-2I 2-channel repeater power supply, Ex i Data sheet 105571_en_00 1 © PHOENIX CONTACT 2014-05-13 Description The 2-channel repeater power supply is designed for the operation of intrinsically safe (Ex-i) 2-wire measuring transducers installed in the Ex area. The 2-wire measuring transducers are supplied with power and analog 4...20 mA measured values from the Ex area are transferred to the non-Ex area. The output of the module is active. The analog measured value on the Ex or non-Ex side can be overlayed with digital (HART) communication signals and transmitted bidirectionally. Sockets are integrated into the COMBICON connectors for connecting HART communicators. The module is suitable for safety-related applications up to SIL 3 according to IEC/EN 61508. Features – – – – – – – – – – – – – – 2-channel 4 ... 20 mA input, intrinsically safe, [Ex ia], powered 4 ... 20 mA output, active HART-compatible Error indication according to NAMUR NE 43 Up to SIL 3 according to IEC/EN 61508 5-way electrical isolation Safe electrical isolation between inputs and outputs, supply Power supply possible via DIN rail connector Installation in Ex zone 2 permitted Plug-in connection terminal blocks, either screw or spring-cage connection technology (Push-in technology) Housing width of 12.5 mm Low power dissipation High transmission accuracy WARNING: Explosion hazard The device is an associated item of equipment (category 1) with “intrinsic safety” protection type and can be installed in zone 2 potentially explosive areas as a category 3 device. It meets the requirements of EN 600790:2009, EN 60079-11:2012, and EN 60079-15:2010. When installing and operating the device, the applicable safety directives (including national safety directives), accident prevention regulations, as well as general technical regulations must be observed. Make sure you always use the latest documentation. It can be downloaded from the product at phoenixcontact.net/products. This data sheet is valid for all products listed on the following page: MACX MCR-EX-SL-RPSS-2I-2I 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Safety regulations and installation notes.................................................................................. 5 5.1 Installation notes ................................................................................................................. 5 5.2 Intrinsic safety ..................................................................................................................... 5 5.3 Installation in Zone 2............................................................................................................. 5 5.4 Safety-related applications (SIL) .............................................................................................. 5 6 Installation ............................................................................................................................... 6 6.1 Structure ........................................................................................................................... 6 6.2 Basic circuit diagram with connection terminal blocks ................................................................... 6 6.3 Dimensions ........................................................................................................................ 7 6.4 Assembly........................................................................................................................... 7 6.5 Connecting the cables .......................................................................................................... 8 6.6 Power supply ...................................................................................................................... 9 7 Comparison of the safety data ................................................................................................. 9 8 Safety-related applications .................................................................................................... 10 8.1 Safety characteristic data .................................................................................................... 10 8.2 Conditions ....................................................................................................................... 11 8.3 Installation and startup ........................................................................................................ 11 8.4 Notes on operation ............................................................................................................. 11 8.5 Recurring checks ............................................................................................................... 12 8.6 Repair ............................................................................................................................. 12 8.7 Standards ........................................................................................................................ 12 8.8 Abbreviations ................................................................................................................... 13 105571_en_00 PHOENIX CONTACT 2 MACX MCR-EX-SL-RPSS-2I-2I 3 Ordering data Description Type Order No. Pcs. / Pkt. Ex i measuring transducer repeater power supply, 2-channel; HART-trans- MACX MCR-EX-SL-RPSS-2I-2I parent. Supplies Ex i 2-wire measuring transducers and transmits the 4 - 20 mA signal from the Ex area to the safe area. 5-way electrical isolation, up to SIL 3 according to IEC 61508; screw connection. 2865382 1 Ex i measuring transducer repeater power supply, 2-channel; HART-trans- MACX MCR-EX-SL-RPSS-2I-2I-SP parent. Supplies Ex i 2-wire measuring transducers and transmits the 4 - 20 mA signal from the Ex area to the safe area. 5-way electrical isolation, up to SIL 3 according to IEC 61508; spring-cage connection. 2924676 1 Accessories Order No. Pcs. / Pkt. DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold- ME 6,2 TBUS-2 1,5/5-ST-3,81 GN plated contacts, 5-pos. Plug component 2869728 10 Power and error message module MACX MCR-PTB 2865625 1 Power and error message module, spring-cage terminal blocks MACX MCR-PTB-SP 2924184 1 4 Type Technical data Input data Description of the input Intrinsically safe Current input signal 4 mA ... 20 mA Transmitter supply voltage > 16 V (at 20 mA) Underload/overload signal range 0 mA ... 24 mA Output Output description Current output Current output signal 4 mA ... 20 mA (active) Transmission Behavior 1:1 to input signal Load/output load current output ≤ 450 Ω (20 mA) ≤ 375 Ω (24 mA) Output behavior in the event of an error < 3.6 mA (In the event of cable break at the input (as per NE 43)) > 22.5 mA (In the event of cable short circuit at the input (as per NE 43)) Underload/overload signal range 0 mA ... 24 mA Supply Nominal supply voltage 24 V DC Supply voltage range 19.2 V DC ... 30 V DC (24 V DC (-20% ... +25%)) Max. current consumption < 100 mA (24 V / 20 mA) Power loss < 1.4 W (at 24 V DC / 20 mA) General data HART function Yes Protocols supported HART Signal bandwidth as per HART specifications Transmission error, typical < 0.05 % (of final value) Maximum transmission error < 0.1 % (of final value) Maximum temperature coefficient < 0.01 %/K Step response (10-90%) < 1.3 ms (for 4 mA ... 20 mA step) Degree of protection IP20 Inflammability class according to UL 94 V0 105571_en_00 PHOENIX CONTACT 3 MACX MCR-EX-SL-RPSS-2I-2I General data [...] Surge voltage category II Pollution degree 2 Diameter Test socket 2.3 mm Status display Green LED (supply voltage) Dimensions W / H / D 12.5 mm / 99 mm / 114.5 mm Type of housing PA 66-FR green Connection data Screw connection Conductor cross section, solid 0.2 mm² ... 2.5 mm² 0.2 mm² ... 1.5 mm² Conductor cross section, stranded 0.2 mm² ... 2.5 mm² 0.2 mm² ... 1.5 mm² Conductor cross section AWG/kcmil 24 ... 14 24 ... 16 Stripping length 7 mm 8 mm Tightening torque 0.5 Nm ... 0.6 Nm Spring-cage connection Ambient conditions Ambient temperature (operation) -20 °C ... 60 °C (Any mounting position) Ambient temperature (storage/transport) -40 °C ... 80 °C Permissible humidity (operation) 10 % ... 95 % (non-condensing) Maximum altitude for use above sea level ≤ 2000 m Electrical isolation Input/output, power supply Rated insulation voltage (surge voltage category II; pollution degree 2, safe isolation as per EN 61010-1) 50 Hz, 1 min., test voltage 2.5 kV Input/output Peak value in accordance with EN 60079-11 375 V Input/power supply Peak value in accordance with EN 60079-11 375 V Output 1/output 2/ power supply 50 Hz, 1 min., test voltage 1.5 kV 300 Vrms Safety data as per ATEX Max. output voltage Uo 25.2 V Max. output current Io 93 mA Max. output power Po 587 mW Group ( Max. external inductivity Lo / Max. external capacitance Co ) IIB : 4 mH / 820 nF IIC : 2 mH / 107 nF Safety-related maximum voltage Um 253 V AC (125 V DC) Conformance with EMC Directive 2004/108/EC Noise immunity according to EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Noise emission according to EN 61000-6-4 Conformance / approvals Conformance CE-compliant, additionally EN 61326 ATEX ( BVS 13 ATEX E 001 X )  II (1) G [Ex ia Ga] IIC/IIB  II (1) D [Ex ia Da] IIIC  II 3(1) G Ex nA [ia Ga] IIC T4 Gc IECEx ( IECEx BVS 13.0007X ) [Ex ia Ga] IIC/IIB [Ex ia Da] IIIC Ex nA [ia Ga] IIC T4 Gc Functional safety (SIL) SIL 3 105571_en_00 PHOENIX CONTACT 4 MACX MCR-EX-SL-RPSS-2I-2I 5 Safety regulations and installation notes 5.1 Installation notes • • • • • 5.2 • • • The device is a piece of equipment (category 1) which belongs to the "Intrinsic Safety" ignition protection class and can be installed in Ex zone 2 as a category 3 device. It meets the requirements of EN 60079-0:2012, EN 60079-11:2012, EN 60079-15:2010, IEC 60079-0 ed. 6.0, IEC 60079-11 ed. 6.0, and IEC 60079-15 ed. 4.0. Installation, operation, and maintenance may only be carried out by qualified electricians. Follow the installation instructions as described. When installing and operating the device, the applicable regulations and safety directives (including national safety directives), as well as general technical regulations, must be observed. For the safety technology data, see this packing slip and the certificates (EC examination certificate and other approvals if appropriate). The device must not be opened or modified. Do not repair the device yourself, replace it with an equivalent device. Repairs may only be carried out by the manufacturer. The manufacturer is not liable for damage resulting from violation. The IP20 protection (IEC 60529/EN 60529) of the device is intended for use in a clean and dry environment. The device must not be subject to mechanical strain and/or thermal loads, which exceed the limits described. The device complies with the EMC regulations for industrial areas (EMC class A). When using the device in residential areas, it may cause radio interference. 5.3 • • • 5.4 Installation in Zone 2 Observe the specified conditions for use in potentially explosive areas! Install the device in a suitable approved housing with a minimum of IP54 protection) that meets the requirements of EN 60079-15. Observe the requirements of EN 60079-14. In potentially explosive areas, terminals may only be snapped onto or off the DIN rail connector and wires may only be connected or disconnected when the power is switched off. The device must be stopped and immediately removed from the Ex area if it is damaged, was subject to an impermissible load, stored incorrectly or if it malfunctions. Safety-related applications (SIL) When using the device in safety-related applications, observe the instructions in “Safety-related applications”, as the requirements differ for safety-related functions. Intrinsic safety The device is approved for intrinsically safe (Ex-i) circuits up to Ex zone 0 (gas) and Ex zone 20 (dust). The safety technology values for intrinsically safe equipment and the connecting lines must be observed for the hookup process (IEC/EC 60079-14) and the values specified in this installation note and/or the EC examination certificate must be observed. When carrying out measurements on the intrinsically safe side, observe the relevant regulations regarding the connection of intrinsically safe equipment. Use only these approved measuring devices in intrinsically safe circuits. If the device was used in circuits which are not intrinsically safe, it is forbidden to use it again in intrinsically safe circuits. Label the device clearly as being not intrinsically safe. 105571_en_00 PHOENIX CONTACT 5 MACX MCR-EX-SL-RPSS-2I-2I 6 6.2 Installation Basic circuit diagram with connection terminal blocks NOTE: Electrostatic discharge 6.1 OUT IN Sensor / Field The device contains components that can be damaged or destroyed by electrostatic discharge. When handling the device, observe the necessary safety precautions against electrostatic discharge (ESD) according to EN 61340-5-1 and IEC 61340-5-1. passive 4.2 - 4.2 CH1 + 4.1 4.1 3.2 active active GND +24V 1.2 rg ,G 82 5B MA 2.2 2.1berg lom 2.1 MA ,G + + T 5.2 4.2 - R PW 2 HHT 1.1 – – IN 4.2 4.1 5.2 5.1 Zone 2 Basic circuit diagram Input (intrinsically safe) HHT 2 3 4 3.2 OU 5.1 HHT HHT 1 3.1 4.1 IN 4.2 4.1 5.2 5.1 Bild 1 2.2 [EX ia] HHT - R 2.1 + 4.2 PW D [EX ia] + + 4.1 - 1.2 MACX MCR-EX-SL-RPSS-2I-2I 5.2 GN 1.1 + - 5.1 IZE D 3.2 Bild 2 HHT x. Va lue s CH CH 1 4 .1 Zo 2 - 5 |4.2 ne .1 U2.1 Div |5.2 O , 2 V . I O OC.2= ,I 2 P SC = 5,2 3.1 O , 93 V 3 P .2 O m = 58 A se 7 em mW OU an T ua l Zone 0,1,2 Zone 20,21,22 1.2 1.1 2.2 2.1 3.2 3.1 CH 1 D 1.1 2.2 2.1 3.2 +2 .1 43V HHT GN 1.2 HHT 4V 1.1 CH 1 +2 + - 3 IZE D HHT x. Va lue s CH CH 1 4 .1 Zo 2 5 |4.2 ne .1|5 Div .2 U O , V . I O OC = ,I 2 P SC = 5,2 O , 93 V P O m = 58 A se 7 em mW an ua l D IN WH . 2 [Ex ZO EN E ia 0 NE NE Ma mA ] RG 2 4 .. 3.1 CH 2 CH 2 D IN WH . 2 [Ex ZO EN E ia 0 NE NE Ma mA ] RG 2 4 .. + m am b + m am b + 4 + GND +24V 2.2 C C Su Re erman Re erman O X Or X M U pp U pp d.- 3.2 CR ly peate y wrd.- MCR ly peate y ww n = n = -E r w3.1No Ou 24 VDCVolt r Poww.pNo.: -EX O 24 VD Vo ag Pow .phoe.: 28 X-S t we hoe 28 -SL 4 utp C (-2lt (-2 ag 4 .. pu er L r S nix 65 -RU ... 20 ut 0%/+2e: . t 0%/+2e: 53 -RP Su nixc6 c U 20m 3 P mA up on 8 5% 5% 82 pp onta SS A = ) ) ply tac 2 T S= S 25 T 253 ly -2IHA t.co -20-32VI-A2 HA ct.co -20 V A 2IRT mWA ° ... + C,I 12 RT m WA ° ... C, 12 SP + 5 6 R / DD RNIN 60°C 5V DC /D DO NIN 0°C/- V DC /-4 O u ua G 4° N NO G ° a ... ... lC AN l O AN T +1 +1 CThS D IN D IN SE 40 40 ha EP a °F °F P nn AR Inp STA ARA Inp STAnn el LL eAl TE LL TE ut u .2 t 1 E E MACX MCR-EX-SL-RPSS-2I-2I-SP be 1.2 2.1 - 1.2 1.1 32 lom 2.2 2.2 CH2 2.1 Power 5B + passive 1 82 - HHT HHT 32 3.1 HHT Structure Su 3.2 CH1 3.1 5.2 - 5.2 CH2 + 5.1 5.1 1.1 PLC / DCS AI Channel 1: connection of 2-wire transmitters or 2-wire measuring transducers at terminals 4.1 (+) and 4.2 (-) Channel 2: connection of 2-wire transmitters or 2-wire measuring transducers at terminals 5.1 (+) and 5.2 (-) HART communicators (HHT) can be connected as shown in the basic circuit diagram. Test sockets (diameter 2.3 mm) have been integrated for this purpose. Structure Plug-in COMBICON screw or spring-cage terminal block with integrated test socket Green “PWR” LED, power supply Snap-on foot for DIN rail mounting Connection option for DIN rail connector Always adhere to the safety regulations (1.2. Intrinsic safety). Output – – Channel 1: active output (terminals 3.1 (+) and 3.2 (-)) for connecting passive analog input cards Channel 2: active output (terminals 2.1 (+) and 2.2 (-)) for connecting passive analog input cards HART communicators (HHT) can be connected as shown in the basic circuit diagram. Test sockets (diameter 2.3 mm) have been integrated for this purpose. 105571_en_00 PHOENIX CONTACT 6 MACX MCR-EX-SL-RPSS-2I-2I 6.3 Dimensions 6.4 116 (SP) 112,5 99 Assembly WARNING: Explosion hazard 12,5 7 If the device has been used in non-intrinsically safe circuits, it must not be used again in intrinsically safe circuits. 114,5 The device must be clearly marked as non-intrinsically safe. Bild 3 105571_en_00 Dimensions EN / UL 61010-1: • Provide for a switch/circuit-breaker in the vicinity of a device that is marked as disconnect device for this device. • Provide overcurrent protection (I ≤ 16 A) within the installation. • To protect the device against mechanical or electrical damage, install it in a suitable housing with appropriate degree of protection as per IEC 60529. • During maintenance work, disconnect the device from all effective power sources. • If the device is not used as described in the documentation, the intended protection can be negatively affected. • Thanks to its housing, the device has basic insulation to the neighboring devices, for 300 Veff. If several devices are installed next to each other, this has to be taken into account, and additional insulation has to be installed if necessary! If the neighboring device is equipped with basic insulation, no additional insulation is necessary. • The voltages present at the input, output, and supply are extra-low voltages (ELV). Depending on the application, hazardous voltage (> 30 V) to ground may occur. Safe electrical isolation between inputs and outputs and between the inputs and the supply exists for such cases. PHOENIX CONTACT 7 MACX MCR-EX-SL-RPSS-2I-2I A B C 6.5 • • • Connecting the cables Screw terminal blocks: fit the litz wires with ferrules, permitted conductor cross section: 0.2 mm² to 2.5 mm² Spring-cage terminal blocks: fit the litz wires with ferrules, permitted conductor cross section: 0.2 mm² to 1.5 mm² Install intrinsically safe and non-intrinsically safe cables separately Screw Connection AWG 24-14 2 0,2-2,5 mm MACX MCR-... A Bild 4 Mounting and removing 7 mm • • • • • Mount the device on a 35 mm DIN rail according to DIN EN 60715. When using the DIN rail connector, first insert it in the 35 mm DIN rail according to EN 60715 (A - C). DIN rails with a height of 7.5 mm or more can be used. The DIN rail connector is used to bridge the power supply and communication. The snap-in direction of the device and DIN rail connector must be observed: snap-on foot on the bottom and plug on the left. Install the module in a suitable housing to meet the requirements for the protection class. Before startup, check that the device is operating and wired correctly, in particular with regard to the wiring and marking of the intrinsically safe circuits. B Bild 5 • • 0,5-0,6 Nm 5-7 lb In Screw connection Insert the wire into the corresponding connection terminal block. Use a screwdriver to tighten the screw in the opening above the connection terminal block. Tightening torque: 0.6 Nm Spring-cage connection: AWG 24-16 2 0,2-1,5 mm MACX MCR-...-SP A B 8 mm A Bild 6 • 105571_en_00 Spring-cage connection Insert the wire into the corresponding connection terminal block. PHOENIX CONTACT 8 MACX MCR-EX-SL-RPSS-2I-2I 6.6 Power supply 7 Comparison of the safety data NOTE Never connect the supply voltage directly to the DIN rail connector. It is not permitted to draw power from the DIN rail connector or from individual modules. The supply voltage can be supplied via terminal points 1.1 and 1.2 or via the DIN rail connector. WARNING: Explosion hazard Compare the safety data before connecting a device located in the Ex i area to this device. Provide proof of intrinsic safety according to standard IEC/ EN 60079-14 and other national standards and installation specifications, if applicable. Safety data Supply via the MACX Analog Ex module Where the total current consumption of the aligned modules does not exceed 400 mA, the power can be supplied directly at the connection terminal blocks of the module. Up to 16 modules can be supplied depending on the current consumption of the modules. We recommend connecting a 630 mA fuse (normal-blow or slow-blow) upstream. Supply via power and error message module Field devices Ex repeater power supply Ui, Ii, Pi, Li, Ci Uo, Io, Po, Lo, Co The values for Uo, Io, Po, Lo, Co can be found under “Safety data according to ATEX” in the “Technical data” section. Example for proof of intrinsic safety (simple circuit) Ui  Uo Ii  Io Pi  Po The MACX MCR-PTB (Order No. 2865625) or the MACX MCR-PTB-SP (Order No. 2924184) supply and error message module is used to provide the supply voltage to the DIN rail connector. Simple or redundant diode-decoupled power supply is possible. Li + Lc  Lo Ci + Cc  Co Lc and Cc depend on the cables used. Condition Li  1% of Lo or Ci  1% of Co Depending on the current consumption of the modules, up to 150 individual modules can be supplied by a supply that is protected by a fuse. The module has integrated error evaluation. An auxiliary supply failure or fuse fault is indicated at a relay contact and displayed via a flashing LED. 105571_en_00 PHOENIX CONTACT 9 MACX MCR-EX-SL-RPSS-2I-2I 8 Safety-related applications 8.1 Safety characteristic data In SIL 2 applications, if the percentage of the device for the entire safety chain is assumed to be a maximum of 10%, a maintenance/test interval of 4 years can be achieved. The following notes apply for the devices: Designation MACX MCR-EX-SL-RPSS-2I-2I MACX MCR-EX-SL-RPSS-2I-2I-SP Order No. 2865382 2924676 Single-channel version In the case of the single-channel version, each of the two channels can be used for a (different) safety function. The following then applies for the safety function: – Type A device (according to EN 61508-2) – Safety integrity level (SIL) 2 and 3 – HFT 0 – MTTR 24 h – Ambient temperature 40°C Sensor 25 % Device 21 mA). The range from 3.6 ... 21 mA is considered the valid signal range. Output values outside this range are considered as the safe state, which is detected by the subsequent controller. The failure rates in FIT for each of the channels are as follows: SU 316 SD 0 DU 55 DD 345 SFF 92.27% DCD 86.25% PFDavg values T [PROOF] PFDavg 1 year 2.52 10-4 4 years 9.79 10-4 5 years 1.22 10-3 Output values outside this range are considered as the safe state, which is detected by the subsequent controller. Safe failures in the device are therefore errors where the device sends output signals that deviate from the relevant input signals by no more than 2%. Dangerous failures are errors where the device does not follow a change in the input signal or deviates from the input signal by more than 2% and is not outside the range. Errors that can be detected as dangerous failures are those which send a signal outside the standard range (< 3.6 mA and > 21 mA). The failure rates in FIT for the entire device are as follows: PFH = 5.53 * 10-8/h The device is therefore suitable for SIL 3 applications. 105571_en_00 SU 549 SD 0 DU 92 DD 567 SFF 92.36% DCD 86.04% PHOENIX CONTACT 10 MACX MCR-EX-SL-RPSS-2I-2I PFDavg values T [PROOF] PFDavg 8.3 1 year 0.91 10-4 5 years 4.15 10-4 10 years 8.27 10-4 Installation and startup NOTE: Installation, operation, and maintenance may only be carried out by qualified specialist personnel. PFH = 1.99 * 10-8/h When calculating the average probability of a dangerous failure on demand, errors with the same cause were taken into consideration and a β or βD factor of 2% was determined. The device is therefore suitable for SIL 3 applications. In SIL 2 applications, if the percentage of the device for the entire safety chain is assumed to be a maximum of 10%, a maintenance/test interval of 10 years can be achieved. Sensor 25 % Device
2865382
物料型号:MACX MCR-EX-SL-RPSS-2I-2I

器件简介: - 这是一个2通道的中继电源,设计用于在Ex区域内操作本安型(Ex-i) 2线制测量变送器。 - 该电源为2线制测量变送器提供动力,并把模拟的4...20 mA测量值从Ex区域传输到非Ex区域。

引脚分配: - 输入(本安型):通道1和通道2分别在4.1(+)和4.2(-)、5.1(+)和5.2(-)处连接2线制变送器或测量变送器。 - 输出:通道1的主动输出(3.1(+)和3.2(-))连接被动模拟输入卡;通道2的主动输出(2.1(+)和2.2(-))连接被动模拟输入卡。

参数特性: - 2通道4...20 mA输入,本安型,[Ex ia],动力4...20 mA输出,活跃的HART兼容。 - 错误指示符合NAMUR NE 43,根据IEC/EN 61508可达SIL 3,5路电气隔离。

功能详解: - 该模块适用于安全相关的应用,根据IEC/EN 61508可达SIL 3。 - 模拟测量值可以在Ex或非Ex侧与数字(HART)通信信号叠加,并双向传输。 - COMBICON连接器中集成了用于连接HART通信器的插座。

应用信息: - 可用于安全相关的应用,根据IEC/EN 61508可达SIL 3。 - 适用于Ex zone 2的安装,符合EN 60079:2009, EN 60079-11:2012, 和 EN 60079-15:2010的要求。

封装信息: - 外壳宽度为12.5mm,低功耗,高传输精度。 - 提供DIN导轨连接器安装选项,允许在Ex区域2内安装。