https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Ex i repeater power supply and input isolating amplifier, HART Sends fed or active 0/4-20 mA signals from the Ex
area to a load (active or passive) to the safe area. Electrical 3-way isolation; SIL 2, wide range power supply.
Product Features
■
■
■
■
■
■
■
■
■
250 Ω resistor that can be activated via DIP switches to increase HART impedance for low-resistance systems
Installation in zone 2, protection type "n" (EN 60079-15) permitted
Up to SIL 2 according to EN 61508
Wide-range power supply of 19.2 ... 253 V AC/DC
3-way electrical isolation
Plug-in screw or spring-cage connection technology (Push-in technology), with integrated sockets for HART communicators
0/4 ... 20 mA input, [Ex ia] IIC (powered or not powered)
Bidirectional transmission of digital HART communication signals
0/4 ... 20 mA output (active or passive), 0/1 ... 5 V, can be selected via DIP switches
Key Commercial Data
Packing unit
1 pc
Weight per Piece (excluding packing)
140.0 g
Custom tariff number
85437090
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
05/06/2016 Page 1 / 7
https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Technical data
Dimensions
Width
17.5 mm
Height
99 mm
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Maximum altitude
≤ 2000 m
Permissible humidity (operation)
10 % ... 95 % (non-condensing)
Noise immunity
EN 61000-6-2 When being exposed to interference, there may be minimal
deviations.
Degree of protection
IP20
Input data
Signal input
Active current input, intrinsically safe
Current input signal
4 mA ... 20 mA
Transmitter supply voltage
> 16 V (20 mA)
> 15.3 V (22.5 mA)
Signal input
Passive current input, intrinsically safe
Current input signal
0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop
< 3.5 V (in input isolating amplifier operation)
Output data
Signal output
Current output
Voltage output signal
1 V ... 5 V (internal resistance, 250 Ω, 0.1%)
Current output signal
4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior
1:1 to input signal
Load/output load current output
< 600 Ω (20 mA)
< 525 Ω (22.5 mA)
Output ripple
< 20 mVrms
Output behavior in the event of an error
0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal output
Current output (active and passive)
Voltage output signal
0 V ... 5 V (internal resistance, 250 Ω, 0.1%)
Current output signal
0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
05/06/2016 Page 2 / 7
https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Technical data
Output data
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Load/output load current output
< 600 Ω (20 mA)
< 525 Ω (22.5 mA)
Output ripple
< 20 mVrms
Output behavior in the event of an error
0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)
Power supply
Designation
Repeater power supply operation
Supply voltage range
24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Max. current consumption
< 80 mA (24 V DC / 20 mA)
Power consumption
< 1.6 W (24 V DC/ 20 mA)
Connection data
Conductor cross section solid min.
0.2 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section flexible min.
0.2 mm²
Conductor cross section flexible max.
2.5 mm²
Conductor cross section AWG min.
24
Conductor cross section AWG max.
14
Stripping length
7 mm
Screw thread
M3
Connection method
Screw connection
Tightening torque, min
0.5 Nm
Tightening torque max
0.6 Nm
General
No. of channels
1
Maximum transmission error
< 0.1 % (of final value)
Transmission error, typical
< 0.05 % (of final value)
Maximum temperature coefficient
< 0.01 %/K
Step response (10-90%)
< 600 µs (for 4 mA ... 20 mA step)
Status display
Green LED (supply voltage)
Flammability rating according to UL 94
V0
Degree of pollution
2
Overvoltage category
II
Electromagnetic compatibility
Conformance with EMC directive
Emitted interference
EN 61000-6-4
Housing material
PA 66-FR
05/06/2016 Page 3 / 7
https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Technical data
General
Color
green
Designation
Input/output/power supply
Electrical isolation
300 Vrms (Rated insulation voltage (overvoltage category II; degree of
pollution 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
Designation
Input/output
Electrical isolation
375 V (Peak value in accordance with EN 60079-11)
Designation
Input/power supply
Electrical isolation
375 V (Peak value in accordance with EN 60079-11)
Conformance
CE-compliant, additionally EN 61326
ATEX
II (1) G [Ex ia Ga] IIC/IIB
II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx
[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC/IIB T4 Gc
UL, USA / Canada
Class I Div 2; IS for Class I, II, III Div 1
Functional Safety (SIL)
SIL 2
Data communication (bypass)
HART function
Yes
Protocols supported
HART
Safety data
Operation
Repeater power supply operation
Max. output voltage Uo
25.2 V
Max. output current Io
93 mA
Max. output power Po
587 mW
Group
IIC
Max. external inductivity Lo
2 mH
Max. external capacity Co
107 nF
Group
IIB
Max. external inductivity Lo
4 mH
Max. external capacity Co
820 nF
Safety-related maximum voltage Um
253 V AC/DC (Supply terminals)
Operation
Signal conditioner operation
Input voltage Ui
≤ 30 V
Input current Ii
≤ 150 mA
05/06/2016 Page 4 / 7
https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Technical data
Safety data
Max. internal inductance Li
negligible
Max. internal capacitance Ci
negligible
EMC data
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
Typical deviation from the measuring range final value
1%
Designation
Fast transients (burst)
Standards/regulations
EN 61000-4-4
Typical deviation from the measuring range final value
1%
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Typical deviation from the measuring range final value
1%
Standards and Regulations
Electromagnetic compatibility
Conformance with EMC directive
Noise emission
EN 61000-6-4
Designation
Electromagnetic RF field
Standards/regulations
EN 61000-4-3
EN 61000-4-4
Designation
Conducted interferences
Standards/regulations
EN 61000-4-6
Flammability rating according to UL 94
V0
Conformance
CE-compliant, additionally EN 61326
ATEX
II (1) G [Ex ia Ga] IIC/IIB
II (1) D [Ex ia Da] IIIC
II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx
[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC/IIB T4 Gc
UL, USA / Canada
Class I Div 2; IS for Class I, II, III Div 1
Group
IIC
IIB
Classifications
eCl@ss
eCl@ss 4.0
27210121
05/06/2016 Page 5 / 7
https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Classifications
eCl@ss
eCl@ss 4.1
27210121
eCl@ss 5.0
27210121
eCl@ss 5.1
27210121
eCl@ss 6.0
27210121
eCl@ss 7.0
27210121
eCl@ss 8.0
27210120
eCl@ss 9.0
27210120
ETIM
ETIM 2.0
EC001431
ETIM 3.0
EC001596
ETIM 4.0
EC001596
ETIM 5.0
EC002653
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
Approvals
Approvals
Approvals
UL Listed / cUL Listed / Functional Safety / EAC / cULus Listed
Ex Approvals
IECEx / UL Listed / cUL Listed / ATEX / EAC Ex / cULus Listed
Approvals submitted
GL
Approval details
05/06/2016 Page 6 / 7
https://www.phoenixcontact.com/us/products/2865793
Power/input isolating amplifier - MACX MCR-EX-SL-RPSSI-I-UP - 2865793
Approvals
UL Listed
cUL Listed
Functional Safety
EAC
cULus Listed
Drawings
Block diagram
OUT
IN
Sensor / Field
Dimensional drawing
116 (SP)
112,5
PLC / DCS
AI
- 4.2
+
4.1
99
passive
4.3
S2
4.2
250 Ω
S1
3.2
3.2
3.1
17,5
+
3.1
250 Ω
4.1
3.3
or
+
4.2
3.3
24...230 V –
~
AC/DC
-
1.2
1.1
Zone 0,1,2
Zone 20,21,22
Zone 2
Div. 1,2
Div. 2
3.2
+
114,5
active
- 4.3
Phoenix Contact 2016 © - all rights reserved
http://www.phoenixcontact.com
05/06/2016 Page 7 / 7