ETD-SL-2T-I
Timer relay with adjustable pulse and pause times
Data Sheet
102572_en_03
co
© PHOENIX CONTACT - 04/2008
Features
–
–
–
–
–
Adjustable pulse and pause times
Time range of 50 ms to 100 hours (seven setting ranges)
Timer function
Wide-range power supply unit
Two floating PDTs
on
lin
e
co
m
po
ne
Increasingly higher demands are being placed on safety and
system availability – across all sectors. Processes are
becoming more and more complex, not only in mechanical
engineering and the chemical industry, but also in plant and
automation technology. Demands on power engineering are
also increasing constantly.
The timer relays in the ETD series can be used to control time
sequences in production and process technology.
s.
Description
nt
1
m
INTERFACE
WARNING: Risk of electric shock
Never carry out work when voltage is present.
Make sure you always use the the latest documentation.
It can be downloaded at www.download.phoenixcontact.com.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
ETD-SL-2T-I
2
Ordering data
Description
Type
Order No.
Pcs.
Pkt.
Timer relay with adjustable pulse and pause times
ETD-SL-2T-I
2866174
1
3
Technical data
Input data
24 V DC ... 240 V DC -20 % ... +25 %
24 V AC ... 240 V AC -15 % ... +10 %
48 Hz ... 63 Hz
≤ 0.01 %/K
Recovery time
500 ms
co
Nominal frequency
Temperature coefficient, typical
m
Input voltage range
50 ms ... 100 h (7 time end ranges)
Function
lp: Switched-mode beginning with the pause
li: Switched-mode beginning with the pulse
s.
Time setting range
± 1 % (of scale end value)
Setting accuracy
≤ 5 % (of scale end value)
Repeat accuracy
≤ 0.5 % ±5 ms
Nominal power consumption
2.5 VA (1 W)
ne
nt
Basic accuracy
Output data
2 floating PDT contacts
po
Contact type
Nominal insulation voltage
250 V AC (in acc. with IEC 60664-1)
750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Interrupting rating (ohmic load) max.
m
Output fuse
co
General data
Service life mechanical
Switching frequency
Operating mode
Degree of protection
on
Pollution degree
lin
e
Service life, electrical
Surge voltage category
5 A (fast-blow)
Approx. 2 x 107 cycles
Approx. 2 x 105 cycles at ohmic load, 1000 VA
Max. 60 (per minute at 100 VA ohmic load)
Max. 6 (per minute at 1000 VA ohmic load)
100% operating factor
IP40 (housing) / IP20 (connection terminal blocks)
3
III
Rated surge voltage
4 kV (basic insulation)
Inflammability class acc. to UL 94
V0
Assembly
on TS 35 profile rail acc. to EN 60715
Mounting position
Any
Width
22.5 mm
Height
113 mm
Length
90 mm
Type of housing
Polyamide PA, self-extinguishing
Color
green
Weight
160 g
102572_en_03
PHOENIX CONTACT
2
ETD-SL-2T-I
Connection data
Conductor cross section, solid
0.5 mm2 ... 2.5 mm2
Conductor cross section, stranded
0.5 mm2 ... 2.5 mm2
Stripping length
8 mm
Type of connection
Screw connection
Tightening torque
1 Nm
Ambient conditions
-25 °C ... 55 °C
-25 °C ... 40 °C (corresponds to UL 508)
Ambient temperature (storage/transport)
-25 °C ... 70 °C
15 % ... 85 %
Climatic class
3K3 (in acc. with EN 60721)
Conformance / approvals
CE compliant
UL, USA / Canada
UL/C-UL listed UL 508
Block diagram
16
18
26
28
ne
A1
po
t
25
lin
e
Safety notes
15
co
U = 24...240 V AC/DC
m
A2
5
nt
4
s.
Conformity
co
Permissible humidity (operation)
m
Ambient temperature (operation)
WARNING: Risk of electric shock
on
Never carry out work when voltage is present.
102572_en_03
PHOENIX CONTACT
3
ETD-SL-2T-I
6
Structure
1
1
2
3
4
5
6
7
8
"U/t" LED: Supply and adjustable time TIME
"REL" LED: Output relay
"FUNCTION" rotary switch: Function selection
Rotary switch "TIME2": Time end range
"TIME2" potentiometer: Preset value
Rotary switch "TIME1": Time end range
"TIME1" potentiometer: Preset value
Universal snap-on foot for EN DIN rails
A1
.4
.6
1
lp
FU
NC
TIO
N
26
18 28
A2
3
6
7
Installation
WARNING: Risk of electric shock
po
7
4
5
s.
li
1 h
10
100
nt
25
16
8
.8
E2
1 1
0
REL
2
mT IM
10
1
1 h
10
100
ne
.2
.05
s
1
E1
1 1
0
co
mT IM
10
1
.8
Timer
s
m
.6
ETD-SL-2T-I
U/t
15
.4
.2
.05
Never carry out work when voltage is present.
m
The module can be snapped onto all 35 mm DIN rails according to EN 60715.
A1
.4
.2
U/t
on
15
.05
.6
.8
1
TIM E1
1
m
s
lin
e
Time setting
Timer
8
co
An integrated wide-range power supply unit enables the connection of a supply voltage in the range from 24 V AC/DC to
240 V AC/DC.
h
1 10 1
.4
.2
.6
Setting of time 1
1 Specification of the time end range using a rotary switch,
e.g. 10 m (10 minutes)
2 Fine setting of the time using a potentiometer, e.g. 0.4
Set time: 0.4 * 10 minutes = 4 minutes
10
100
10
1
2
Example:
.8
1
.05
TIM E2
m
10
100
10
1
lp
REL
li
FUNCTION
25
16
102572_en_03
26
18
ETD-SL-2T-I
s
h
1 10 1
28
A2
PHOENIX CONTACT
4
ETD-SL-2T-I
9
Diagnostics
The LEDs indicate the following error states:
"U/t" LED (Green)
–
–
LED flashes at 0.75 Hz: Voltage present, set time t1 running
LED flashes at 1.5 Hz: Voltage present, set time t2 running
"REL" LED (Yellow)
m
Connection example
25
16 18
26 28
26
16
18
28
A2
on
lin
e
25
co
15
po
15
m
A1
ne
nt
s.
10
LED ON: Output relay has picked up
LED OFF: Output relay has dropped out
co
–
–
102572_en_03
PHOENIX CONTACT
5
ETD-SL-2T-I
11
Function
ATTENTION: Module can become damaged
Only set the functions when the module is switched off.
lp: Switched-Mode Beginning With Pause
t2
t1
t2
ne
nt
t1
s.
LED REL, R
co
m
U
LED U/t
When supply voltage U is applied, set time t1 starts running
(green "U/t" LED flashes at 0.75 Hz). Once time t1 has
elapsed, the output relay picks up (yellow "REL" LED is ON)
and set time t2 starts running (green "U/t" LED flashes at 1.5
Hz).
Once time t2 has elapsed, the output relay drops out (yellow
"REL" LED is OFF). The output relay is controlled in relation
to set times t1 and t2 until the supply voltage is interrupted.
Time t1 = Pause time
Time t2 = Pulse time
li: Switched-Mode Beginning With Pulse
po
When supply voltage U is applied, the output relay picks up
(yellow "REL" LED is ON) and set time t1 starts running
(green "U/t" LED flashes at 0.75 Hz). Once time t1 has
elapsed, the output relay drops out (yellow "REL" LED is
OFF) and set time t2 starts running (green "U/t" LED flashes
at 1.5 Hz).
Once time t2 has elapsed, the output relay picks up again
(yellow "REL" LED is ON). The output relay is controlled in
relation to set times t1 and t2 until the supply voltage is
interrupted.
Time t1 = Pulse time
Time t2 = Pause time
LED REL, R
t2
t1
t2
on
lin
e
t1
co
m
U
LED U/t
102572_en_03
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00
PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300
www.phoenixcontact.com
6
很抱歉,暂时无法提供与“2866174”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+1387.226741+179.81100