STEP-PS/48AC/24DC/0.5
Primary-switched power supply unit
INTERFACE
Data sheet
106206_en_00
1
© PHOENIX CONTACT - 09/2014
Description
STEP POWER power supplies for installation distributors
The STEP POWER power supply range was developed
especially for building automation. The low idling losses and
high degree of efficiency ensure maximum energy efficiency.
They allow flexible use and can be snapped onto the DIN rail
or screwed onto an even surface.
Features
–
–
–
–
–
–
–
–
Easy assembly on the DIN rail or panel
Maximum energy efficiency thanks to low idling losses
Quick startup with LED function monitoring
High operating safety due to long mains buffering under
full load and high MTBF (> 500,000 h)
Can be used worldwide in all industrial sectors due to a
wide-range input and an international approval package
Wide temperature range of -25°C to +70°C
Parallel connection possible for increased performance
and redundancy
Powerful in its particularly slim design (18 mm)
EXPLOSION HAZARD!
Only remove equipment when it is disconnected and not in the potentially explosive area.
DANGER
The device contains dangerous live elements and high levels of stored energy.
Never carry out work when the power is turned on.
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
Produktbezeichnung
2
1
Table of contents
Description ..................................................................................................................................1
Features .........................................................................................................................................................1
2
Table of contents.........................................................................................................................2
3
Ordering data .............................................................................................................................. 3
4
Technical data............................................................................................................................. 4
5
Structure......................................................................................................................................7
6
Block diagram ............................................................................................................................. 8
7
Safety notes ................................................................................................................................8
8
Installation ...................................................................................................................................9
9
Mounting position ........................................................................................................................9
10 Mounting on DIN rails ................................................................................................................ 10
Assembly......................................................................................................................................................10
Removing .....................................................................................................................................................10
11 Input .......................................................................................................................................... 10
Protection of the primary side .......................................................................................................................10
Permissible backup fuse for mains protection...............................................................................................10
12 Output ....................................................................................................................................... 11
Protection of the secondary side...................................................................................................................11
13 Signaling ................................................................................................................................... 11
14 Function .................................................................................................................................... 12
Output characteristic curve ...........................................................................................................................12
Thermal behavior..........................................................................................................................................12
Parallel operation..........................................................................................................................................13
Redundant operation ....................................................................................................................................13
Increased performance.................................................................................................................................13
106206_en_00
PHOENIX CONTACT
2
Produktbezeichnung
3
Ordering data
Description
Type
Order No.
Pcs. / Pkt.
Primary-switched STEP POWER power supply for DIN rail mounting, input:
1-phase, output: 24 V DC/0.5 A
STEP-PS/48AC/24DC/0.5
2868716
1
Accessories
Type
Order No.
Pcs. / Pkt.
Redundancy module, 5-24 V DC, 2x 5 A, 1x 10 A
STEP-DIODE/5-24DC/2X5/1X10
2868606
1
106206_en_00
PHOENIX CONTACT
3
Produktbezeichnung
4
Technical data
Input data
Nominal input voltage
48 V AC
Input voltage range AC
43 V AC ... 52 V AC
Input voltage range DC
60 V DC ... 80 V DC
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Current consumption
0.5 A (43 V AC)
0.45 A (48 V AC)
Inrush current limitation
< 10 A (typical)
I2t
< 0.1 A2s
Power failure bypass
> 15 ms (48 V AC)
> 20 ms (52 V AC)
Typical response time
< 0.5 s
Input fuse, integrated
1.25 A (slow-blow, internal)
Output data
Nominal output voltage
24 V DC ±1 %
Output current
0.5 A (-25°C ... 55°C)
0.55 A (-25 °C ... 40 °C permanent)
1 A (maximum output current)
Control deviation
< 1 % (change in load, static 10 % ... 90 %)
< 2 % (change in load, dynamic 10 % ... 90 %)
< 0.1 % (change in input voltage ±10 %)
Efficiency
> 81 % (for 48 V AC and nominal values)
Residual ripple
< 30 mVPP (20 MHz)
Peak switching voltages
< 20 mVPP (20 MHz)
Connection in parallel
Yes, for redundancy and increased capacity
Connection in series
Yes
Protection against surge voltage on the output
< 35 V DC
Resistance to reverse feed
≤ 35 V DC
Power consumption
Maximum power dissipation NO-Load
< 0.3 W
Power loss nominal load max.
< 3.4 W
LED status indicator
Status display
"DC OK" LED green / UOUT > 21.5 V: LED lights up
General data
Insulation voltage input/output
4 kV AC (type test)
3.75 kV AC (routine test)
Degree of protection
IP20
Protection class
II (in closed control cabinet)
MTBF (IEC 61709, SN 29500)
> 1860000 h (40°C)
Housing material
Polycarbonate
Foot latch material
Plastic POM
Dimensions W / H / D (state of delivery)
18 mm / 90 mm / 61 mm
Weight
0.07 kg
106206_en_00
PHOENIX CONTACT
4
Produktbezeichnung
Ambient conditions
Ambient temperature (operation)
-25 °C ... 70 °C (> 55 °C Derating: 2,5 %/K)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. permissible relative humidity (operation)
≤ 95 % (at 25 °C, non-condensing)
Vibration (operation)
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
15 Hz ... 150 Hz, 2.3g, 90 min.
Shock
30g in each direction, according to IEC 60068-2-27
Pollution degree in acc. with EN 50178
2
Climatic class
3K3 (in acc. with EN 60721)
Standards
Electrical Equipment for Machinery
EN 60204 / Surge voltage category III
Safety transformers for power supply units
EN 61558-2-16
Electrical safety (of information technology equipment)
IEC 60950-1/VDE 0805 (SELV)
Electronic equipment for use in electrical power installations
EN 50178/VDE 0160 (PELV)
SELV
IEC 60950-1 (SELV) and EN 60204 (PELV)
Safe isolation
DIN VDE 0100-410
Protection against electric shock, basic requirements for safe isolation in
electrical equipment
DIN VDE 0106-101
Limitation of mains harmonic currents
EN 61000-3-2
Approvals
UL approvals
106206_en_00
UL/C-UL listed UL 508
UL/C-UL Recognized UL 60950
NEC Class 2 as per UL 1310
PHOENIX CONTACT
5
Produktbezeichnung
Conformance with EMC Directive 2004/108/EC
Noise immunity according to EN 61000-6-2
Electrostatic discharge
EN 61000-4-2
Housing
Contact discharge
Electromagnetic HF field
6 kV (Test intensity 3)
Discharge in air
8 kV (Test intensity 3)
Comments
Criterion A
EN 61000-4-3
Housing
Fast transients (burst)
Surge current loads (surge)
Conducted interference
Frequency range
80 MHz ... 3 GHz
Field intensity
10 V/m (Test intensity 3)
Comments
Criterion A
EN 61000-4-4
Input
2 kV (Test intensity 3 - asymmetrical)
Output
2 kV (Test intensity 3 - asymmetrical)
Comments
Criterion A
EN 61000-4-5
Input
1 kV (Test intensity 2 - symmetrical)
2 kV (Test intensity 3 - asymmetrical)
Output
0.5 kV (Test intensity 1 - symmetrical)
1 kV (Test intensity 2 - asymmetrical)
Comments
Criterion A
EN 61000-4-6
Input/output
Test intensity 3
Frequency range
150 kHz ... 80 MHz
Voltage
10 V
Comments
Criterion A
Emitted interference in acc. with EN 61000-6-3
Radio interference voltage in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
Emitted radio interference in acc. with EN 55011
EN 55011 (EN 55022) Class B, area of application: Industry and residential
106206_en_00
PHOENIX CONTACT
6
Produktbezeichnung
5
Structure
4
2
1
2
3
4
AC input
DC output
"DC OK" LED, green
Universal snap-on foot for EN DIN rails and for wall
mounting
3
1
Input
Output
[mm²]
solid
stranded
0.2 - 2.5 0.2 - 2.5
0.2 - 2.5 0.2 - 2.5
AWG
24 - 12
24 - 12
[Nm]
Torque
0.6 - 0.8
0.6 - 0.8
Input data
Nominal input voltage
48 V AC
Input voltage range AC
43 V AC ... 52 V AC
Input voltage range DC
60 V DC ... 80 V DC
AC frequency range
45 Hz ... 65 Hz
Frequency range DC
0 Hz
Input fuse, integrated
1.25 A (slow-blow, internal)
Connection method
Screw connection
Stripping length
6.5 mm
Output data
Nominal output voltage
24 V DC ±1 %
Output current
0.5 A (-25°C ... 55°C)
0.55 A (-25 °C ... 40 °C permanent)
1 A (maximum output current)
Connection method
Screw connection
Stripping length
6.5 mm
106206_en_00
PHOENIX CONTACT
7
Produktbezeichnung
6
Block diagram
+
-
L (+)
N (-)
7
Safety notes
EXPLOSION HAZARD!
Only remove equipment when it is disconnected and not in the potentially explosive area.
DANGER
The device contains dangerous live elements and high levels of stored energy.
Never carry out work when the power is turned on.
WARNING:
Before startup please ensure:
The mains connection has been carried out by a competent person and protection against electric shock is
guaranteed!
The device can be disconnected outside the power supply unit in accordance with the regulations as in EN
60950 (e.g. through primary side line protection)!
All feed lines are sufficiently protected and dimensioned!
All output lines are dimensioned according to the maximum output current of the device or separately
protected!
Sufficient convection must be guaranteed.
CAUTION:
The power supply units are built-in devices. The device may only be installed and put into operation by qualified
personnel. The corresponding national regulations must be observed.
106206_en_00
PHOENIX CONTACT
8
Produktbezeichnung
8
Installation
NOTE:
In order to ensure sufficient convection, we
recommend a minimum vertical distance of
30 mm to the other devices.
The power supply unit can be snapped onto all
DIN rails as per EN 60715; it can also be
mounted on walls. The device must be
mounted vertically (connecting terminals
above or below).
9
Mounting position
18
55
30
150
90
45
30
44
50
61
106206_en_00
PHOENIX CONTACT
9
Produktbezeichnung
10
Mounting on DIN rails
Assembly
To mount on an EN DIN rail, snap the device straight onto the
DIN rail.
If the power supply unit is to be fastened directly onto an even
surface, press the orange base latch upward and down.
Place a washer between the pulled-out base latch and the
even surface (max. outer diameter 8.5 mm, max. thickness
1.3 mm, e.g., spring washer for M4 in acc. with DIN 127-B or
toothed lock washer in acc. with DIN 6797).
Then fasten the device with two screws (max. thread
diameter 4 mm, max. head diameter 8.5 mm).
Removing
To dismantle from the EN DIN rail, press the orange base
latch outward and pull the device off of the DIN rail.
In the case of wall mounting, loosen the screws and press the
base latch inwards again.
11
Input
CAUTION:
If an internal fuse is triggered, there is a device
malfunction. In this case, the device must be
inspected in the factory.
Protection of the primary side
43-52 V
The device must be installed in acc. with the regulations as in
EN 60950. It must be possible to disconnect the device using
a suitable isolating facility outside the power supply.
The primary side line protection, for example, is suitable. For
device protection, there is an internal fuse. Additional device
protection is not necessary.
Permissible backup fuse for mains protection
Power circuit-breaker 6 A, 10 A or 16 A, characteristic B (or
identical function).
106206_en_00
PHOENIX CONTACT
10
Produktbezeichnung
12
Output
CAUTION:
Make sure that all output lines are dimensioned
according to the maximum output current or are
separately protected. The cables on the
secondary side must have sufficiently large
cross sections in order to keep the voltage
drops on the lines as low as possible.
The connection is made using the "+" and "-" screw
connections on the screw connection of the DC output. The
set output voltage is 24 V DC at the time of delivery.
Protection of the secondary side
The device is electronically protected against short-circuit
and idling. In the event of a malfunction, the output voltage is
limited to 35 V DC.
13
Signaling
The "DC OK" LED enables evaluation of the function of the power supply directly on site.
State 1
State 2
"DC OK" LED
ON
OFF
Cause
Output voltage > 21.5 V
Output voltage