2878971

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    POWERSUPPLYMODULE230V

  • 数据手册
  • 价格&库存
2878971 数据手册
IB IL 230 PWR IN/F-D (-PAC) Inline power terminal, 230 V AC, with fuse and diagnostics AUTOMATION Data sheet 7187_de_01 1 © PHOENIX CONTACT 2011-06-14 Description This terminal is designed for use within an Inline station. It enables input of the 230-V-AC-supply voltage into a 230-VAC area of an Inline station. The end clamp (IB IL AC END) that is used for terminating the 230-V-AC area is supplied as standard. The terminal is equipped with elements for protection against surge voltage. The internal fuse protects the L phase. The terminal is equipped with an LED for diagnostics and occupies two input data bits, which are used to indicate the presence of the supply voltage and the state of the fuse Features – – – Supplying the L phase (230 V AC) Diagnostic indicators Protecting the L phase by an internal fuse WARNING: dangerous contact voltage Connecting and disconnecting the Inline terminals for the 230 V AC voltage range is only permitted when the power supply is disconnected! This data sheet is only valid in association with the IL SYS INST UM E user manual. Make sure you always use the latest documentation. It can be downloaded from the product at www.phoenixcontact.net/catalog. IB IL 230 PWR IN/F-D (-PAC) 2 Table of contents 1 Description .............................................................................................................................. 1 2 Table of contents ..................................................................................................................... 2 3 Ordering data .......................................................................................................................... 3 4 Technical data ......................................................................................................................... 3 5 Internal circuit diagram ............................................................................................................ 5 6 Intended use............................................................................................................................ 6 7 Local diagnostic indicators ...................................................................................................... 6 8 Terminal point assignment....................................................................................................... 7 9 Connection example................................................................................................................ 7 10 Installation and startup............................................................................................................. 7 11 Process data............................................................................................................................ 8 7187_de_01 PHOENIX CONTACT 2 IB IL 230 PWR IN/F-D (-PAC) 3 Ordering data Description Type Order No. Pcs. / Pkt. Inline power terminal, complete with accessories (connector and labeling field), 230 V AC, with fuse and diagnostics IB IL 230 PWR IN/F-D-PAC 2878971 1 Inline power terminal, without accessories, 230 V AC, with fuse and diagnostics IB IL 230 PWR IN/F-D 2878081 1 Accessories Type Order No. Pcs. / Pkt. Connector set, for Inline input terminal blocks with AC voltage ( Plug/Adapter ) IB IL AC-PWR-IN-PLSET 2740180 1 10 Labeling field, width: 12.2 mm ( Marking ) IB IL FIELD 2 2727501 Insert strip for laser printer, lettering field: 62 x 10 mm ( Marking ) ESL 62X10 0809492 1 Replacement fuse ( Fuse ) SI 5X20 6,3 A T DIN 41662 2726104 10 Documentation Type Order No. Pcs. / Pkt. User manual, English, Automation terminals of the Inline product range IL SYS INST UM E - - 4 Technical data Dimensions (nominal sizes in mm) 140,5 71,5 119,8 Width 36.6 mm Height 119.8 mm Depth 71.5 mm Wide power terminal block 24.4 mm Wide end terminal block 12.2 mm General data Color Gray Weight 80 g Mounting type DIN rail Ambient temperature (operation) -25 °C ... 55 °C Ambient temperature (storage/transport) -25 °C ... 85 °C Permissible humidity (operation) 10 % ... 95 % (according to DIN EN 61131-2) Permissible humidity (storage/transport) 10 % ... 95 % (according to DIN EN 61131-2) 7187_de_01 PHOENIX CONTACT 3 IB IL 230 PWR IN/F-D (-PAC) General data Air pressure (operation) 70 kPa ... 106 kPa (up to 2000 m above mean sea level) Air pressure (storage/transport) 70 kPa ... 106 kPa (up to 3000 m above mean sea level) Degree of protection IP20 Protection class I, IEC 61140, EN 61140, VDE 0140-1 Connection data Name Inline connectors Connection method Spring-cage connection Conductor cross section solid / stranded 0.08 mm² ... 1.5 mm² Conductor cross section [AWG] 28 ... 16 Interface Interface Inline local bus Connection method Inline data jumper Power consumption Main circuit supply UM 230 V AC (nominal value) Peripherals voltage range 207 V AC ... 253 V AC (including all tolerances, including ripple) Power supply at UM 8 A (nominal value) Communications power UL 7.5 V DC (via voltage jumper) Current consumption from UL 25 mA Programming Data ID code (hex) BE ID code (dec.) 190 Length code (hex) C2 Length code (dec.) 194 Process data channel 2 Bit Input address area 2 Bit Output address area 0 Byte Parameter channel (PCP) 0 Byte Register length 2 Bit For the programming data/configuration data of other bus systems, please refer to the corresponding electronic device data sheet (e.g., GSD, EDS). PROFIBUS telegram data Required parameter data 1 Byte Need for configuration data 4 Byte Electrical isolation/isolation of the voltage areas 5 V supply, incoming remote bus/7.5 V supply (bus logics) 500 V AC , 50 Hz , 1 min 5 V supply, outgoing remote bus/7.5 V supply (bus logics) 500 V AC , 50 Hz , 1 min 7.5 V supply (bus logic) / peripheral range 230 V AC 2500 V AC , 50 Hz , 1 min 7.5 V supply (bus logic) / peripheral range 230 V AC (routine test) 1200 V AC , 50 Hz , 1 min Peripheral range 230 V AC / PE 500 V AC , 50 Hz , 1 min Output / Phase 500 V AC , 50 Hz , 1 min Approvals For the latest approvals, please visit www.phoenixcontact.net/catalog. 7187_de_01 PHOENIX CONTACT 4 IB IL 230 PWR IN/F-D (-PAC) 5 Internal circuit diagram IB IL AC END IB IL 230 PWR IN/2-F-D-PAC Local bus OPC D UL+ UANA UL- E L L N Figure 1 Internal wiring of the terminal points Key: Optocoupler LED Protocol chip (Bus logic including voltage conditioning) OPC Terminal point without metal contact Terminal point without metal contact with filler plugs Explanation for other used symbols has been provided in the IL SYS INST UM E user manual. 7187_de_01 PHOENIX CONTACT 5 IB IL 230 PWR IN/F-D (-PAC) 6 Intended use The terminal is only to be used within an Inline station in accordance with the specifications in the data sheet and IL SYS INST UM E user manual. Phoenix Contact accepts no liability when used for anything other than its intended purpose. 7 Local diagnostic indicators B A L D E D Figure 2 Local diagnostic indicators A B LED D E L L E Power terminal End terminal Color Green Red Red off Red off Green Green OFF Green ON Meaning Diagnostics (bus and logic voltage) Fuse Fuse OK Fuse blown Supply voltage 230 V AC No supply voltage Supply voltage is available If there is no L phase or the fuse has blown or is missing, an I/O error message is generated for the higher-level control or computer system. A blown or missing fuse is indicated via both diagnostics displays. The LED E lights up and the green LED D flashes at 2 Hz. Function identification Flashing white light 7187_de_01 PHOENIX CONTACT 6 IB IL 230 PWR IN/F-D (-PAC) 8 Terminal point assignment B 9 Connection example WARNING: dangerous contact voltage 3 Protect the 230 V AC supply via an external fuse! 3 A 1 2 L D 1 2 2.1 1.1 2.1 1.1 2.1 1.2 2.2 1.2 2.2 1.2 2.2 L 1.3 2.3 1.3 2.3 1.3 2.3 N 1.4 2.4 1.4 2.4 1.4 2.4 230 V AC E 1.1 2.1 1.2 2.2 1.3 2.3 1.4 2.4 Figure 4 10 Figure 3 1.1 Terminal point assignment Typical connection of the supply voltage Installation and startup Strictly observe the instructions in the data sheet and the IL SYS INST UM E user manual during installation and startup. Installing the system Terminal Designa- Assignment point tion Power terminal (A) Connector 1 All   Not used Connector 2 (marked according to function) 1.1 / 2.1   Not used 1.2 / 2.2 L Supply points for the phase of the L supply; Terminal points bridged internally 1.3 / 2.3 N Neutral conductor connection; terminal points bridged internally 1.4 PE Protective conductor connection; the contact is connected directly to the PE potential jumper. Ground the terminal via the PE connection! This ensures protective earth ground connection of all terminals within this area when the 230 V AC area is correctly established. 2.4   Not used End clamp (B) Connector 3 All   Not used 7187_de_01 Install the system according to the requirements of EN 50178! Only qualified personnel may work on low voltage area Inline terminals. Qualified personnel are people who, because of their education, experience and instruction and their knowledge of relevant standards, regulations, accident prevention and service conditions, have been authorized by those responsible for the safety of the plant, to carry out any required operations and who are able to recognize and avoid any possible dangers. (definitions for skilled workers according to EN 50110-1:1996). PHOENIX CONTACT 7 IB IL 230 PWR IN/F-D (-PAC) WARNING: dangerous contact voltage Please be aware of dangerous voltages when working on circuits that do not meet SELV requirements. Installing the Inline station The maximum total current flowing through the potential jumpers is 8 A. WARNING: Connecting and disconnecting the Inline terminals for the 230 V AC voltage range is only permitted when the power supply is disconnected! Use the intended power connector for supplying the voltage. The full current carrying capacity is ensured by internal bridging of the terminal points (see connection assignment). When working on the terminals and wiring, always switch off the supply voltage and ensure it cannot be switched on again. Failure to observe these instructions can lead to damage to health or even life-threatening injuries. WARNING: dangerous contact voltage in the event of ground faults (if for example, the FI switch is triggered or star point is "exposed") Only operate Inline terminals for 230 V AC voltage range in grounded AC voltage networks. If it is necessary to establish another voltage range behind the 230 V AC area, terminate the 230 V area with an end clamp and begin the new voltage area with a new power terminal. Startup of an Inline station An Inline station may only be put into operation when it is completely installed. That means: – all terminals must be properly snapped in with their connectors. – The station must be terminated with the end plate and the two end clamps. WARNING:multiple supplies are not permitted! Observe the specifications in the IL SYS INST UM E user manual on the low voltage area. The supply voltage may only be connected to the intended power terminal. The connecting cables of all actuators and sensors may only be connected to the Inline AC terminals. 11 Process data Do not use external busbars for group potentials! The input process data only maps the status of the fuse and the main voltage. (Byte.Bit) view Assign- Phase L exists, fuse is OK ment Phase L exists, fuse has blown or is missing Phase L does not exist, fuse has blown or is missing 0.1 1 0 0.0 1 1 0 0 For the assignment of the illustrated (byte.bit) view to your INTERBUS control or computer system, please refer to the DB GB IBS SYS ADDRESS data sheet. 7187_de_01 PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 www.phoenixcontact.com 8
2878971 价格&库存

很抱歉,暂时无法提供与“2878971”相匹配的价格&库存,您可以联系我们找货

免费人工找货