Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control
voltage, and screw connection.
Why buy this product
22.5 mm wide
Reduction in wiring
Space saving
Long service life
3-phase loop bridges
Low-wear switching
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4046356526104
Weight per Piece (excluding packing)
220.000 g
Custom tariff number
85371098
Country of origin
Germany
Technical data
Device supply
Rated control circuit supply voltage US
24 V DC
Control supply voltage range
19.2 V DC ... 30 V DC
Rated control supply current IS
40 mA
Type of protection
Surge protection
04/17/2018 Page 1 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Technical data
Device supply
Reverse polarity protection
Input data
Input name
Control input right/left
Rated actuating voltage UC
24 V DC
Triggering voltage range
19.2 V DC ... 30 V DC
Rated actuating current IC
5 mA (Input type 1)
Switching threshold
9.6 V (“0” signal)
19.2 V (“1” signal)
Typical turn-off time
< 30 ms
Type of protection
Reverse polarity protection
Output data load output
Output name
AC output
Rated operating voltage Ue
500 V AC
Operating voltage range
42 V AC ... 550 V AC
Rated operating current Ie
9 A (AC-51)
6.5 A (AC-53a)
Mains frequency
50/60 Hz
Load current range
0 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2
-
Leakage current
0 mA
Type of protection
Surge protection
General
Switching frequency
≤ 2 Hz (Load-dependent)
Mounting position
vertical (horizontal DIN rail, motor output below)
Mounting type
DIN rail mounting
Assembly instructions
alignable, for spacing see derating
Operating mode
100% operating factor
Maximum power dissipation
7W
Minimum power dissipation
0.88 W
Operating voltage display
Green LED
Status display
Yellow LED
Connection data, input side
Connection name
Control circuits
Connection method
Screw connection
Stripping length
8 mm
04/17/2018 Page 2 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Technical data
Connection data, input side
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Torque
0.5 Nm ... 0.6 Nm
Connection data, output side
Connection name
Load circuit
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Torque
0.5 Nm ... 0.6 Nm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Degree of protection
IP20
Dimensions
Width
22.5 mm
Height
106.6 mm
Depth
113.7 mm
UL data
SCCR
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA
6.5 A (500 V AC)
Group installation
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Category code
NLDX / NRNT
Insulation characteristics
Rated insulation voltage
500 V
Rated surge voltage
6 kV
Overvoltage category
III
Degree of pollution
2
04/17/2018 Page 3 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Technical data
Insulation characteristics
Designation
Insulation characteristics between the control input and control supply
voltage, and auxiliary circuit to the main circuit
Insulation
Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
Designation
Isolation characteristics between the control input and control supply
voltage to auxiliary circuit
Insulation
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Standards and Regulations
Designation
Standards/regulations
Standards/regulations
IEC 60947-1
IEC 60947-4-2
IEC 61508
ISO 13849
Approvals/conformities
UL certificate
NLDX.E228652
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category
“Manufacturer's declaration”
Drawings
Load current [A]
Diagram
Block diagram
1/L1 3/L2 5/L3
9
8
7
6
5
4
3
2
1
0,18
Us
T
Logic
µP
R
0
50
60
70
Ambient temperature [°C]
= aligned with > 20 mm spacing
= aligned without spacing
10
20
30
40
L
2/T1 4/T2 6/T3
Derating diagram
04/17/2018 Page 4 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Classifications
eCl@ss
eCl@ss 5.0
27024002
eCl@ss 5.1
27024002
eCl@ss 6.0
27024002
eCl@ss 7.0
27024002
eCl@ss 8.0
27024002
eCl@ss 9.0
27024002
ETIM
ETIM 2.0
EC001037
ETIM 3.0
EC001037
ETIM 4.0
EC001037
ETIM 5.0
EC001037
ETIM 6.0
EC001037
UNSPSC
UNSPSC 6.01
30211915
UNSPSC 7.0901
39121514
UNSPSC 11
39121514
UNSPSC 12.01
39121514
UNSPSC 13.2
25173902
Approvals
Approvals
Approvals
UL Listed / cUL Listed / IECEE CB Scheme / UL Listed / cUL Listed / EAC / EAC / CCC-s / cULus Listed
Ex Approvals
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 228652
04/17/2018 Page 5 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Approvals
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 228652
IECEE CB Scheme
http://www.iecee.org/
DE1-55728
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 323771
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 323771
EAC
EAC-Zulassung
EAC
RU CDE.A*30.B.01082
http://www.china-certification.com
2016010304871315
CCC-s
cULus Listed
Accessories
Accessories
Bridge
04/17/2018 Page 6 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Accessories
Jumper - BRIDGE- 4-3M - 2901659
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Cover
Covering hood - BRIDGE COVER - 2906240
The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently
be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.
Device marking
Plastic label - US-EMLP (15X5) - 0828790
Plastic label, Card, white, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, mounting
type: adhesive, lettering field size: 15 x 5 mm
Plastic label - UC-EMLP (15X5) - 0819301
Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK CLED, BLUEMARK LED, CMS-P1-PLOTTER,
PLOTMARK, mounting type: adhesive, lettering field size: 15 x 5 mm
Loop bridge
04/17/2018 Page 7 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Accessories
Jumper - BRIDGE- 2 - 2900746
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 3 - 2900747
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 4 - 2900748
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 5 - 2900749
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 6 - 2900750
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
04/17/2018 Page 8 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Accessories
Jumper - BRIDGE- 7 - 2900751
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 8 - 2900752
3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 9 - 2900753
3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE-10 - 2900754
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 2-3M - 2901543
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
04/17/2018 Page 9 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Accessories
Jumper - BRIDGE- 3-3M - 2901656
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 5-3M - 2901545
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 6-3M - 2901697
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 7-3M - 2901698
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 8-3M - 2901700
3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
04/17/2018 Page 10 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Accessories
Jumper - BRIDGE- 9-3M - 2901701
3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE-10-3M - 2901702
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 2-1M - 2901542
3-phase loop bridge for 2 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1
m long connecting cable, without ferrules.
Jumper - BRIDGE- 3-1M - 2901655
3-phase loop bridge for 3 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1
m long connecting cable, without ferrules.
Jumper - BRIDGE- 4-1M - 2901658
3-phase loop bridge for 4 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1
m long connecting cable, without ferrules.
04/17/2018 Page 11 / 12
https://www.phoenixcontact.com/us/products/2900538
Hybrid motor starter - ELR H5-SC- 24DC/500AC-9 - 2900538
Accessories
Jumper - BRIDGE- 5-1M - 2901544
3-phase loop bridge for 5 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1
m long connecting cable, without ferrules.
Jumper - BRIDGE- 6-1M - 2901649
3-phase loop bridge for 6 modules in the CONTACTRON family with 1 m long connecting cable without ferrules, 22.5 mm
housing width.
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
04/17/2018 Page 12 / 12