ELR H3-ES-SC- 24DC/500AC-0,6
Order No.: 2900550
The figure shows the 9 A version
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550
"2 in 1" hybrid motor starter for starting 3~ AC motors up to 550 V AC,
with 24 V DC input, 0.6 A output current, and emergency stop function.
Product notes
WEEE/RoHS-compliant since:
02/09/2010
Commercial data
GTIN (EAN)
4
046356
Note
Made-to-order
sales group
G410
Pack
1 pcs.
Customs tariff
85364900
527729
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Input data
Rated control supply voltage US
24 V DC
Rated control supply voltage range with reference
to US
0.8 ... 1.25
Rated control supply current IS
35 mA
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 1 / 6
May 6, 2011
ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550
Rated actuating voltage UC
24 V DC
Rated actuating voltage range with reference to
UC
0.8 ... 1.25
Rated actuating current IC
3 mA
Switching threshold "0" signal, voltage
9.6 V
Switching threshold "1" signal voltage
19.2 V
Protective circuit
Protection against polarity reversal Parallel polarity protection
diode
Surge protection
Typical response time
< 35 ms
Typical turn-off time
< 40 ms
Operating voltage display
Green LED
Status display
Yellow LED
Indication
Red LED
Output data, load relay
Output name
AC output
Nominal output voltage
500 V AC
Nominal output voltage range
48 V AC ... 550 V AC
Load current
max. 600 mA (see derating curve)
Leakage current
0 mA
Residual voltage
< 0.3 V
Surge current
100 A (t = 10 ms)
Type of protection
Surge protection
Output name
Acknowledge output
Note
Confirmation 01: Floating PDT contact
Nominal output voltage
max. 253 V AC 0% ... 100% (300 V DC)
Continuous load current
2A
Output data, signaling contact
Measuring via
Current transformer for line current on L1 and L3
Connection data
Connection method
Screw connection
Conductor cross section solid min.
0.14 mm²
Conductor cross section solid max.
2.5 mm²
Conductor cross section stranded min.
0.14 mm²
Conductor cross section stranded max.
2.5 mm²
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 2 / 6
May 6, 2011
ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550
Conductor cross section AWG/kcmil min.
26
Conductor cross section AWG/kcmil max
12
General data
Width
22.5 mm
Height
99 mm
Depth
114.5 mm
Test voltage input/output
4 kVrms
Ambient temperature (operation)
-25 °C ... 70 °C
Ambient temperature (storage/transport)
-25 °C ... 70 °C
Mounting position
Vertical (horizontal DIN rail)
Assembly instructions
Can be aligned with spacing = 20 mm
Operating mode
100% operating factor
Degree of protection
IP20
Name
Standards/regulations
Standards/regulations
DIN EN 50178
EN 60947
Name
Power station requirements
Standards/regulations
DWR 1300 / ZXX01/DD/7080.8d
Name
Air and creepage distances between the power circuits
Standards/regulations
DIN EN 50178
Rated surge voltage / insulation
6 kV/safe isolation
Rated insulation voltage
500 V
Pollution degree
2
Surge voltage category
III
Safety integrity level according to IEC 61508-1
SIL 3 (safe shutdown)
Category as per ISO 13849-1
3
Performance Level as per ISO 13849-1
e
Category in acc. with EN 954-1
3
Certificates / Approvals
Certification
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
CB, CUL Listed, UL Listed
Page 3 / 6
May 6, 2011
ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550
Certification Ex:
PTB
Diagrams/Drawings
Block diagram
Circuit diagram
Conventional structure
Main current path for contactor according
to category 3
K1 + K2 = Emergency stop contactor
K3 = Right contactor
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Conventional structure
Control current path for contactor
according to category 3
K1 + K2 = Emergency stop contactor
K3 = Right contactor
K4 = PSR SCP-24DC.../safety relay
T1 = Right, T3 = Reset
S2 = Emergency stop
Page 4 / 6
May 6, 2011
ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550
Structure with CONTACTRON
Main and control current path for "2 in 1" hybrid motor starter
according to category 3
K1 = "2 in 1" hybrid motor starter
K4 = PSR SCP-24DC.../safety relay
T1 = Right, T3 = Reset
S2 = Emergency stop
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 5 / 6
May 6, 2011
ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2011 Phoenix Contact
Technical modifications reserved;
PHOENIX CONTACT Inc., USA
http://www.phoenixcon.com
Page 6 / 6
May 6, 2011