2900550

2900550

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MOTOR STARTER

  • 数据手册
  • 价格&库存
2900550 数据手册
Extract from the online catalog     ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550 The figure shows the 9 A version http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550   "2 in 1" hybrid motor starter for starting 3~ AC motors up to 550 V AC, with 24 V DC input, 0.6 A output current, and emergency stop function.   Product notes WEEE/RoHS-compliant since: 02/09/2010 Commercial data GTIN (EAN) 4 046356 Note Made-to-order sales group G410 Pack 1 pcs. Customs tariff 85364900 527729 http:// www.download.phoenixcontact.com Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation. The General Terms and Conditions of Use apply to Internet downloads. Technical data Input data Rated control supply voltage US 24 V DC Rated control supply voltage range with reference to US 0.8 ... 1.25 Rated control supply current IS 35 mA PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 1 / 6 May 6, 2011 ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550 Rated actuating voltage UC 24 V DC Rated actuating voltage range with reference to UC 0.8 ... 1.25 Rated actuating current IC 3 mA Switching threshold "0" signal, voltage 9.6 V Switching threshold "1" signal voltage 19.2 V Protective circuit Protection against polarity reversal Parallel polarity protection diode Surge protection Typical response time < 35 ms Typical turn-off time < 40 ms Operating voltage display Green LED Status display Yellow LED Indication Red LED Output data, load relay Output name AC output Nominal output voltage 500 V AC Nominal output voltage range 48 V AC ... 550 V AC Load current max. 600 mA (see derating curve) Leakage current 0 mA Residual voltage < 0.3 V Surge current 100 A (t = 10 ms) Type of protection Surge protection Output name Acknowledge output Note Confirmation 01: Floating PDT contact Nominal output voltage max. 253 V AC 0% ... 100% (300 V DC) Continuous load current 2A Output data, signaling contact Measuring via Current transformer for line current on L1 and L3 Connection data Connection method Screw connection Conductor cross section solid min. 0.14 mm² Conductor cross section solid max. 2.5 mm² Conductor cross section stranded min. 0.14 mm² Conductor cross section stranded max. 2.5 mm² PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 2 / 6 May 6, 2011 ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550 Conductor cross section AWG/kcmil min. 26 Conductor cross section AWG/kcmil max 12 General data Width 22.5 mm Height 99 mm Depth 114.5 mm Test voltage input/output 4 kVrms Ambient temperature (operation) -25 °C ... 70 °C Ambient temperature (storage/transport) -25 °C ... 70 °C Mounting position Vertical (horizontal DIN rail) Assembly instructions Can be aligned with spacing = 20 mm Operating mode 100% operating factor Degree of protection IP20 Name Standards/regulations Standards/regulations DIN EN 50178 EN 60947 Name Power station requirements Standards/regulations DWR 1300 / ZXX01/DD/7080.8d Name Air and creepage distances between the power circuits Standards/regulations DIN EN 50178 Rated surge voltage / insulation 6 kV/safe isolation Rated insulation voltage 500 V Pollution degree 2 Surge voltage category III Safety integrity level according to IEC 61508-1 SIL 3 (safe shutdown) Category as per ISO 13849-1 3 Performance Level as per ISO 13849-1 e Category in acc. with EN 954-1 3 Certificates / Approvals Certification PHOENIX CONTACT Inc., USA http://www.phoenixcon.com CB, CUL Listed, UL Listed Page 3 / 6 May 6, 2011 ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550 Certification Ex: PTB Diagrams/Drawings Block diagram Circuit diagram Conventional structure Main current path for contactor according to category 3 K1 + K2 = Emergency stop contactor K3 = Right contactor PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Conventional structure Control current path for contactor according to category 3 K1 + K2 = Emergency stop contactor K3 = Right contactor K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop Page 4 / 6 May 6, 2011 ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550 Structure with CONTACTRON Main and control current path for "2 in 1" hybrid motor starter according to category 3 K1 = "2 in 1" hybrid motor starter K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 5 / 6 May 6, 2011 ELR H3-ES-SC- 24DC/500AC-0,6 Order No.: 2900550 http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2900550 Address PHOENIX CONTACT Inc., USA 586 Fulling Mill Road Middletown, PA 17057,USA Phone (800) 888-7388 Fax (717) 944-1625 http://www.phoenixcon.com © 2011 Phoenix Contact Technical modifications reserved; PHOENIX CONTACT Inc., USA http://www.phoenixcon.com Page 6 / 6 May 6, 2011
2900550 价格&库存

很抱歉,暂时无法提供与“2900550”相匹配的价格&库存,您可以联系我们找货

免费人工找货