0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
2900566

2900566

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

  • 数据手册
  • 价格&库存
2900566 数据手册
https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection. Why buy this product  22.5 mm wide  Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e  Reduction in wiring  Long service life  Space saving  3-phase loop bridges  Adjustable current for bimetal function  Low-wear switching Key Commercial Data Packing unit 1 STK GTIN GTIN 4046356526128 Weight per Piece (excluding packing) 289.000 g Custom tariff number 85371098 Country of origin Germany Technical data Device supply Rated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 40 mA Type of protection Surge protection Reverse polarity protection 08/13/2018   Page 1 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Technical data Input data Input name Control input Rated actuating voltage UC 24 V DC Triggering voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA (Input type 1) Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Typical turn-off time < 30 ms Type of protection Reverse polarity protection Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Rated operating current Ie 0.6 A (AC-51) 0.6 A (AC-53a) Mains frequency 50/60 Hz Load current range 75 mA ... 600 mA (see to derating) Trigger characteristic in acc. with IEC 60947-4-2 Class 10A Cooling time 20 min. (for auto reset) Leakage current 0 mA Type of protection Surge protection Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 PDT Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) General Switching frequency ≤ 2 Hz (Load-dependent) Mounting position vertical (horizontal DIN rail, motor output below) Mounting type DIN rail mounting Assembly instructions alignable, for spacing see derating Operating mode 100% operating factor Maximum power dissipation 2.5 W Minimum power dissipation 0.88 W Operating voltage display Green LED Status display Yellow LED Indication Red LED Connection data, input side 08/13/2018   Page 2 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Technical data Connection data, input side Connection name Control circuits Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm Connection data, output side Connection name Load circuit Connection method Screw connection Stripping length 8 mm Screw thread M3 Conductor cross section solid 0.2 mm² ... 2.5 mm² Conductor cross section flexible 0.2 mm² ... 2.5 mm² Conductor cross section AWG 24 ... 14 Torque 0.5 Nm ... 0.6 Nm Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C Degree of protection IP20 Dimensions Width 22.5 mm Height 106.6 mm Depth 113.7 mm UL data SCCR 100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault))) 5 kA (500 V AC (fuse: 20 A RK5 (standard fault))) FLA 0.6 A (500 V AC) Group installation 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) Category code NLDX Insulation characteristics Rated insulation voltage 500 V Rated surge voltage 6 kV Overvoltage category III Degree of pollution 2 08/13/2018   Page 3 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Technical data Insulation characteristics Designation Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuit Insulation Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC Designation Isolation characteristics between the control input and control supply voltage to auxiliary circuit Insulation Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC Standards and Regulations Designation Standards/regulations Standards/regulations IEC 60947-1 IEC 60947-4-2 IEC 61508 ISO 13849 ATEX # II (2) G [Ex e] [Ex d] [Ex px] # II (2) D [Ex t] [Ex p] Approvals/conformities Safety Integrity Level according to IEC 61508 ≤ 3 (Safe shutdown) 2 (Motor protection) Category acc. to EN ISO 13849 ≤ 3 (Safe shutdown) Performance level according to ISO 13849 ≤ e (Safe shutdown) ATEX # II (2) G [Ex e] [Ex d] [Ex px] # II (2) D [Ex t] [Ex p] EU-type examination certificate PTB 07 ATEX 3145 UL certificate NLDX.E228652 Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” Drawings 08/13/2018   Page 4 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Load current [A] Diagram Block diagram MAN RES AUTO 9 8 7 6 5 4 3 2 1 0,18 1/L1 3/L2 5/L3 RES Logic µP Us T T 0 50 60 70 Ambient temperature [°C] = aligned with > 20 mm spacing = aligned without spacing 10 20 30 40 E & Error ON 97 96 95 2/T1 4/T2 6/T3 Derating diagram Circuit diagram L1 L2 L3 Circuit diagram +24V DC F5 F1 F2 F3 K4 K4 K4 K4 S2 F4 K1 K2 K4 T1 T2 K3 K1 K4 K4 K1 K2 K2 F4 M 3~ M1 K3 PE K4 K4 GND Conventional structure Main current path for contactor according to category 3 Conventional structure Control current path for contactor according to category 3 K1 + K2 = Emergency stop contactor K3 = Right contactor F4 = Motor protection relay K1 + K2 = Emergency stop contactor K3 = Right contactor K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop F4 = Motor protection relay 08/13/2018   Page 5 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Circuit diagram F1 L1 F2 L2 F3 L3 +24V DC K4 L1 L2 L3 T3 K1 T1 T2 T3 T1 K4 M 3~ M1 K4 K1 +US ON K4 K4 K4 K4 S2 E PE K4 GND Structure with CONTACTRON , , Main and control current path for 3 in 1 hybrid motor starter according to category 3 , , K1 = 3 in 1 hybrid motor starter K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop Classifications eCl@ss eCl@ss 5.0 27024002 eCl@ss 5.1 27024000 eCl@ss 6.0 27024000 eCl@ss 7.0 27024002 eCl@ss 8.0 27024002 eCl@ss 9.0 27024002 ETIM ETIM 2.0 EC001037 ETIM 3.0 EC001037 ETIM 4.0 EC001037 ETIM 5.0 EC001037 ETIM 6.0 EC001037 UNSPSC UNSPSC 6.01 30211915 UNSPSC 7.0901 39121514 UNSPSC 11 39121514 UNSPSC 12.01 39121514 08/13/2018   Page 6 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Classifications UNSPSC UNSPSC 13.2 25173902 Approvals Approvals Approvals UL Listed / cUL Listed / IECEE CB Scheme / GL / GL-SW / UL Listed / cUL Listed / EAC / CCC / cULus Listed / GL Ex Approvals ATEX Approval details UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 228652 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 323771 IECEE CB Scheme    http://www.iecee.org/  DE1-55728 GL    http://exchange.dnv.com/tari/  54757-08 HH    54757-08 HH GL-SW  UL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 323771 cUL Listed    http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm  FILE E 228652 08/13/2018   Page 7 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Approvals     RU CDE.A*30.B.01082 CCC      2016010304871315 cULus Listed        http://www.gl-group.com/newbuilding/approvals/index.html   EAC  GL  Accessories Accessories Adapter Adapter - EM-CPS-DA-22,5F/16A - 1002668 ® Device adapter with fuse holder for 16 A fuse (10x38/Class CC), CrossLink interface and fixed DIN rail     Assembly adapter Power distribution board - EM-CPS-225 - 1002634 ® Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 225 mm     Power distribution board - EM-CPS-405 - 1002635 ® Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity reversal, width: 405 mm     08/13/2018   Page 8 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Accessories Connection module - EM-CPS-TB3/63A - 1002633 Connection module with integrated spring-loaded terminals for cables up to 16 mm², 3-pos.,     Bridge Jumper - BRIDGE- 4-3M - 2901659 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Cover Covering hood - BRIDGE COVER - 2906240 The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.     Device marking Plastic label - US-EMLP (15X5) - 0828790 Plastic label, Card, white, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD, BLUEMARK ID, BLUEMARK ID COLOR, mounting type: adhesive, lettering field size: 15 x 5 mm     Plastic label - UC-EMLP (15X5) - 0819301 Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID, BLUEMARK ID COLOR, BLUEMARK CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm     Loop bridge 08/13/2018   Page 9 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Accessories Jumper - BRIDGE- 2 - 2900746 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 3 - 2900747 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 4 - 2900748 3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 5 - 2900749 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 6 - 2900750 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     08/13/2018   Page 10 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Accessories Jumper - BRIDGE- 7 - 2900751 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 8 - 2900752 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 9 - 2900753 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE-10 - 2900754 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 0.3 m, with ferrules.     Jumper - BRIDGE- 2-3M - 2901543 3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     08/13/2018   Page 11 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Accessories Jumper - BRIDGE- 3-3M - 2901656 3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 5-3M - 2901545 3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 6-3M - 2901697 3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 7-3M - 2901698 3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 8-3M - 2901700 3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     08/13/2018   Page 12 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Accessories Jumper - BRIDGE- 9-3M - 2901701 3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE-10-3M - 2901702 3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting cable: 3 m, with ferrules included.     Jumper - BRIDGE- 2-1M - 2901542 3-phase loop bridge for 2 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     Jumper - BRIDGE- 3-1M - 2901655 3-phase loop bridge for 3 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     Jumper - BRIDGE- 4-1M - 2901658 3-phase loop bridge for 4 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     08/13/2018   Page 13 / 14 https://www.phoenixcontact.com/gb/products/2900566 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566 Accessories Jumper - BRIDGE- 5-1M - 2901544 3-phase loop bridge for 5 modules from the CONTACTRON family with screw connection and 22.5 mm housing width, 1 m long connecting cable, without ferrules.     Jumper - BRIDGE- 6-1M - 2901649 3-phase loop bridge for 6 modules in the CONTACTRON family with 1 m long connecting cable without ferrules, 22.5 mm housing width.     Phoenix Contact 2018 © - all rights reserved http://www.phoenixcontact.com 08/13/2018   Page 14 / 14
2900566 价格&库存

很抱歉,暂时无法提供与“2900566”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2900566
  •  国内价格 香港价格
  • 1+1856.939011+232.04256

库存:0