https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control
voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection.
Why buy this product
22.5 mm wide
Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e
Reduction in wiring
Long service life
Space saving
3-phase loop bridges
Adjustable current for bimetal function
Low-wear switching
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4046356526128
Weight per Piece (excluding packing)
289.000 g
Custom tariff number
85371098
Country of origin
Germany
Technical data
Device supply
Rated control circuit supply voltage US
24 V DC
Control supply voltage range
19.2 V DC ... 30 V DC
Rated control supply current IS
40 mA
Type of protection
Surge protection
Reverse polarity protection
08/13/2018 Page 1 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Technical data
Input data
Input name
Control input
Rated actuating voltage UC
24 V DC
Triggering voltage range
19.2 V DC ... 30 V DC
Rated actuating current IC
5 mA (Input type 1)
Switching threshold
9.6 V (“0” signal)
19.2 V (“1” signal)
Switching level
< 5 V DC (For EMERGENCY STOP)
Typical turn-off time
< 30 ms
Type of protection
Reverse polarity protection
Output data load output
Output name
AC output
Rated operating voltage Ue
500 V AC
Operating voltage range
42 V AC ... 550 V AC
Rated operating current Ie
0.6 A (AC-51)
0.6 A (AC-53a)
Mains frequency
50/60 Hz
Load current range
75 mA ... 600 mA (see to derating)
Trigger characteristic in acc. with IEC 60947-4-2
Class 10A
Cooling time
20 min. (for auto reset)
Leakage current
0 mA
Type of protection
Surge protection
Output data reply output
Output name
Acknowledge output
Note
Confirmation: floating change-over contact, signal contact
Contact type
1 PDT
Switching capacity according to IEC 60947-5-1
3 A (230 V, AC15)
2 A (24 V, DC13)
General
Switching frequency
≤ 2 Hz (Load-dependent)
Mounting position
vertical (horizontal DIN rail, motor output below)
Mounting type
DIN rail mounting
Assembly instructions
alignable, for spacing see derating
Operating mode
100% operating factor
Maximum power dissipation
2.5 W
Minimum power dissipation
0.88 W
Operating voltage display
Green LED
Status display
Yellow LED
Indication
Red LED
Connection data, input side
08/13/2018 Page 2 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Technical data
Connection data, input side
Connection name
Control circuits
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Torque
0.5 Nm ... 0.6 Nm
Connection data, output side
Connection name
Load circuit
Connection method
Screw connection
Stripping length
8 mm
Screw thread
M3
Conductor cross section solid
0.2 mm² ... 2.5 mm²
Conductor cross section flexible
0.2 mm² ... 2.5 mm²
Conductor cross section AWG
24 ... 14
Torque
0.5 Nm ... 0.6 Nm
Ambient conditions
Ambient temperature (operation)
-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)
-40 °C ... 80 °C
Degree of protection
IP20
Dimensions
Width
22.5 mm
Height
106.6 mm
Depth
113.7 mm
UL data
SCCR
100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
5 kA (500 V AC (fuse: 20 A RK5 (standard fault)))
FLA
0.6 A (500 V AC)
Group installation
20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and
stranded)
Category code
NLDX
Insulation characteristics
Rated insulation voltage
500 V
Rated surge voltage
6 kV
Overvoltage category
III
Degree of pollution
2
08/13/2018 Page 3 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Technical data
Insulation characteristics
Designation
Insulation characteristics between the control input and control supply
voltage, and auxiliary circuit to the main circuit
Insulation
Safe isolation (IEC 60947-1/EN 50178) at operating voltage ≤ 300 V AC
Basic isolation (IEC 60947-1) at operating voltage 300 ... 500 V AC
Safe isolation (EN 50178) at operating voltage 300 ... 500 V AC
Designation
Isolation characteristics between the control input and control supply
voltage to auxiliary circuit
Insulation
Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Standards and Regulations
Designation
Standards/regulations
Standards/regulations
IEC 60947-1
IEC 60947-4-2
IEC 61508
ISO 13849
ATEX
# II (2) G [Ex e] [Ex d] [Ex px]
# II (2) D [Ex t] [Ex p]
Approvals/conformities
Safety Integrity Level according to IEC 61508
≤ 3 (Safe shutdown)
2 (Motor protection)
Category acc. to EN ISO 13849
≤ 3 (Safe shutdown)
Performance level according to ISO 13849
≤ e (Safe shutdown)
ATEX
# II (2) G [Ex e] [Ex d] [Ex px]
# II (2) D [Ex t] [Ex p]
EU-type examination certificate
PTB 07 ATEX 3145
UL certificate
NLDX.E228652
Environmental Product Compliance
China RoHS
Environmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”,
Category “Manufacturer's declaration”
Drawings
08/13/2018 Page 4 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Load current [A]
Diagram
Block diagram
MAN
RES
AUTO
9
8
7
6
5
4
3
2
1
0,18
1/L1 3/L2 5/L3
RES
Logic
µP
Us
T
T
0
50
60
70
Ambient temperature [°C]
= aligned with > 20 mm spacing
= aligned without spacing
10
20
30
40
E
& Error
ON
97 96 95
2/T1 4/T2 6/T3
Derating diagram
Circuit diagram
L1
L2
L3
Circuit diagram
+24V DC F5
F1
F2
F3
K4
K4
K4
K4
S2
F4
K1
K2
K4
T1
T2
K3
K1
K4
K4
K1
K2
K2
F4
M
3~
M1
K3
PE
K4
K4
GND
Conventional structure
Main current path for contactor according to category 3
Conventional structure
Control current path for contactor according to category 3
K1 + K2 = Emergency stop contactor
K3 = Right contactor
F4 = Motor protection relay
K1 + K2 = Emergency stop contactor
K3 = Right contactor
K4 = PSR SCP-24DC.../safety relay
T1 = Right, T3 = Reset
S2 = Emergency stop
F4 = Motor protection relay
08/13/2018 Page 5 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Circuit diagram
F1
L1 F2
L2 F3
L3
+24V DC
K4
L1 L2 L3
T3
K1
T1 T2 T3
T1
K4
M
3~
M1
K4
K1 +US ON
K4
K4
K4
K4
S2
E
PE
K4
GND
Structure with CONTACTRON
,
,
Main and control current path for 3 in 1 hybrid motor starter according to category 3
,
,
K1 = 3 in 1 hybrid motor starter
K4 = PSR SCP-24DC.../safety relay
T1 = Right, T3 = Reset
S2 = Emergency stop
Classifications
eCl@ss
eCl@ss 5.0
27024002
eCl@ss 5.1
27024000
eCl@ss 6.0
27024000
eCl@ss 7.0
27024002
eCl@ss 8.0
27024002
eCl@ss 9.0
27024002
ETIM
ETIM 2.0
EC001037
ETIM 3.0
EC001037
ETIM 4.0
EC001037
ETIM 5.0
EC001037
ETIM 6.0
EC001037
UNSPSC
UNSPSC 6.01
30211915
UNSPSC 7.0901
39121514
UNSPSC 11
39121514
UNSPSC 12.01
39121514
08/13/2018 Page 6 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Classifications
UNSPSC
UNSPSC 13.2
25173902
Approvals
Approvals
Approvals
UL Listed / cUL Listed / IECEE CB Scheme / GL / GL-SW / UL Listed / cUL Listed / EAC / CCC / cULus Listed / GL
Ex Approvals
ATEX
Approval details
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 228652
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 323771
IECEE CB Scheme
http://www.iecee.org/
DE1-55728
GL
http://exchange.dnv.com/tari/
54757-08 HH
54757-08 HH
GL-SW
UL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 323771
cUL Listed
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 228652
08/13/2018 Page 7 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Approvals
RU CDE.A*30.B.01082
CCC
2016010304871315
cULus Listed
http://www.gl-group.com/newbuilding/approvals/index.html
EAC
GL
Accessories
Accessories
Adapter
Adapter - EM-CPS-DA-22,5F/16A - 1002668
®
Device adapter with fuse holder for 16 A fuse (10x38/Class CC), CrossLink interface and fixed DIN rail
Assembly adapter
Power distribution board - EM-CPS-225 - 1002634
®
Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity
reversal, width: 225 mm
Power distribution board - EM-CPS-405 - 1002635
®
Modular power distribution board with CrossLink interface, 125 A, 3-pos., touch-proof and protection against polarity
reversal, width: 405 mm
08/13/2018 Page 8 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Accessories
Connection module - EM-CPS-TB3/63A - 1002633
Connection module with integrated spring-loaded terminals for cables up to 16 mm², 3-pos.,
Bridge
Jumper - BRIDGE- 4-3M - 2901659
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Cover
Covering hood - BRIDGE COVER - 2906240
The BRIDGE COVER covering hood is used to cover unused plugs on the CONTACTRON bridge that may
subsequently be used to extend the system. The hood can be used with the screw and Push-in version of the bridge.
Device marking
Plastic label - US-EMLP (15X5) - 0828790
Plastic label, Card, white, unlabeled, can be labeled with: THERMOMARK PRIME, THERMOMARK CARD,
BLUEMARK ID, BLUEMARK ID COLOR, mounting type: adhesive, lettering field size: 15 x 5 mm
Plastic label - UC-EMLP (15X5) - 0819301
Plastic label, Sheet, white, unlabeled, can be labeled with: BLUEMARK ID, BLUEMARK ID COLOR, BLUEMARK
CLED, PLOTMARK, CMS-P1-PLOTTER, mounting type: adhesive, lettering field size: 15 x 5 mm
Loop bridge
08/13/2018 Page 9 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Accessories
Jumper - BRIDGE- 2 - 2900746
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 3 - 2900747
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 4 - 2900748
3-phase loop bridge for 4 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 5 - 2900749
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 6 - 2900750
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
08/13/2018 Page 10 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Accessories
Jumper - BRIDGE- 7 - 2900751
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 8 - 2900752
3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 9 - 2900753
3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE-10 - 2900754
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 0.3 m, with ferrules.
Jumper - BRIDGE- 2-3M - 2901543
3-phase loop bridge for 2 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
08/13/2018 Page 11 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Accessories
Jumper - BRIDGE- 3-3M - 2901656
3-phase loop bridge for 3 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 5-3M - 2901545
3-phase loop bridge for 5 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 6-3M - 2901697
3-phase loop bridge for 6 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 7-3M - 2901698
3-phase loop bridge for 7 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 8-3M - 2901700
3-phase loop bridge for 8 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
08/13/2018 Page 12 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Accessories
Jumper - BRIDGE- 9-3M - 2901701
3-phase loop bridge for 9 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE-10-3M - 2901702
3-phase loop bridge for 10 CONTACTRON modules, with screw connection and 22.5 mm housing width, connecting
cable: 3 m, with ferrules included.
Jumper - BRIDGE- 2-1M - 2901542
3-phase loop bridge for 2 modules from the CONTACTRON family with screw connection and 22.5 mm housing
width, 1 m long connecting cable, without ferrules.
Jumper - BRIDGE- 3-1M - 2901655
3-phase loop bridge for 3 modules from the CONTACTRON family with screw connection and 22.5 mm housing
width, 1 m long connecting cable, without ferrules.
Jumper - BRIDGE- 4-1M - 2901658
3-phase loop bridge for 4 modules from the CONTACTRON family with screw connection and 22.5 mm housing
width, 1 m long connecting cable, without ferrules.
08/13/2018 Page 13 / 14
https://www.phoenixcontact.com/gb/products/2900566
Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-0,6 - 2900566
Accessories
Jumper - BRIDGE- 5-1M - 2901544
3-phase loop bridge for 5 modules from the CONTACTRON family with screw connection and 22.5 mm housing
width, 1 m long connecting cable, without ferrules.
Jumper - BRIDGE- 6-1M - 2901649
3-phase loop bridge for 6 modules in the CONTACTRON family with 1 m long connecting cable without ferrules, 22.5
mm housing width.
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
08/13/2018 Page 14 / 14