2900567

2900567

  • 厂商:

    PHOENIX(菲尼克斯)

  • 封装:

    -

  • 描述:

    MOTOR STARTER

  • 数据手册
  • 价格&库存
2900567 数据手册
https://www.phoenixcontact.com/us/products/2900569 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-9 - 2900569 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Hybrid motor starter for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL3 /PL e, and screw connection. Product Features ■ ■ ■ ■ ■ ■ ■ 22.5 mm wide Safety level according to IEC 61508-1: SIL 3, ISO 13849: PL e Reduction in wiring Long service life Space saving 3-phase loop bridges Bimetal function can be set up to 9 A Key Commercial Data Packing unit 1 pc Weight per Piece (excluding packing) 280.0 g Custom tariff number 85371099 Country of origin Germany Technical data Dimensions Width 22.5 mm Height 99 mm Depth 114.5 mm Ambient conditions Ambient temperature (operation) -25 °C ... 70 °C (observe derating) Ambient temperature (storage/transport) -40 °C ... 80 °C 04/11/2016   Page 1 / 8 https://www.phoenixcontact.com/us/products/2900569 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-9 - 2900569 Technical data Ambient conditions Degree of protection IP20 Device supply Rated control circuit supply voltage US 24 V DC Control supply voltage range 19.2 V DC ... 30 V DC Rated control supply current IS 40 mA Protective circuit Reverse polarity protection Parallel polarity protection diode Surge protection Input data Input name Control input right/left Rated actuating voltage UC 24 V DC Voltage range 19.2 V DC ... 30 V DC Rated actuating current IC 5 mA Switching threshold 9.6 V (“0” signal) 19.2 V (“1” signal) Switching level < 5 V DC (For EMERGENCY STOP) Protective circuit Reverse polarity protection Typical turn-off time < 30 ms Output data load output Output name AC output Rated operating voltage Ue 500 V AC Operating voltage range 42 V AC ... 550 V AC Load current range 1.5 A ... 9 A (see to derating) Trigger characteristic in acc. with IEC 60947 Class 10A Cooling time 20 min. (for auto reset) Rated operating current at AC-51 9A Rated operating current at AC-53a 6.5 A Leakage current 0 mA Protective circuit Surge protection Varistor Output data reply output Output name Acknowledge output Note Confirmation: floating change-over contact, signal contact Contact type 1 PDT Switching capacity according to IEC 60947-5-1 3 A (230 V, AC15) 2 A (24 V, DC13) Overspeed tripping 04/11/2016   Page 2 / 8 https://www.phoenixcontact.com/us/products/2900569 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-9 - 2900569 Technical data Overspeed tripping Operate threshold > 45 A Response time 20 mm spacing = aligned without spacing 10 20 30 40 E & Error ON 97 96 95 2/T1 4/T2 6/T3 Derating diagram Circuit diagram L1 L2 L3 Circuit diagram +24V DC F5 F1 F2 F3 K4 K4 K4 K4 S2 F4 K1 K2 K4 T1 T2 K3 K1 K4 K4 K1 K2 K2 F4 M 3~ M1 K3 PE K4 K4 GND Conventional structure Main current path for contactor according to category 3 Conventional structure Control current path for contactor according to category 3 K1 + K2 = Emergency stop contactor K3 = Right contactor K1 + K2 = Emergency stop contactor K3 = Right contactor 04/11/2016   Page 7 / 8 https://www.phoenixcontact.com/us/products/2900569 Hybrid motor starter - ELR H3-IES-SC- 24DC/500AC-9 - 2900569 F4 = Motor protection relay K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop F4 = Motor protection relay Circuit diagram F1 L1 F2 L2 F3 L3 +24V DC K4 L1 L2 L3 T3 K1 T1 T2 T3 T1 K4 M 3~ M1 K4 K1 +US ON K4 K4 K4 K4 S2 E PE K4 GND Structure with CONTACTRON , , Main and control current path for 3 in 1 hybrid motor starter according to category 3 , , K1 = 3 in 1 hybrid motor starter K4 = PSR SCP-24DC.../safety relay T1 = Right, T3 = Reset S2 = Emergency stop Phoenix Contact 2016 © - all rights reserved http://www.phoenixcontact.com 04/11/2016   Page 8 / 8
2900567 价格&库存

很抱歉,暂时无法提供与“2900567”相匹配的价格&库存,您可以联系我们找货

免费人工找货
2900567
  •  国内价格
  • 1+1638.21112

库存:11